Literature DB >> 29393218

Value of Placental Volume and Vascular Flow Indices as Predictors of Early and Late Preeclampsia at First Trimester.

Nieves L González-González1, Enrique González Dávila2, Erika Padrón3, Marina Armas Gonzalez3, Walter Plasencia4.   

Abstract

INTRODUCTION: We evaluated the utility of placental volume and three-dimensional (3D) vascular flow indices to predict early and late preeclampsia.
MATERIAL AND METHODS: In 1,004 pregnancies attending routine care, we recorded first-trimester screening program for aneuploidy (FTSA) parameter and measured uterine artery pulsatility index (uterine-a PI). Placental volume and vascular flow indices were obtained using 3D power Doppler and VOCAL techniques.
RESULTS: Placental volume was lower and uterine-a PI was higher in both early and late preeclampsia groups versus nonaffected pregnancies. The prediction rate of placental volume in late preeclampsia was higher than that of uterine-a PI (AUROC 0.707 vs. 0.581, p < 0.011). The inclusion of placental volume improved significantly the prediction rate of total and late preeclampsia in the models constructed with maternal characteristics, FTSA, and uterine-a PI (AUROC 0.745 vs. 0.818, p < 0.004, and 0.740 vs. 0.812, p < 0.012, respectively). The inclusion of vascular indices did not improve the predictive value of these models. DISCUSSION: Placental volume was an independent predictor of total, early, and late preeclampsia and its inclusion in combined predictive models significantly improved prediction rates. Reduced placental volume observed at first trimester in women with early and late preeclampsia suggests that these entities are the clinical expression of a similar pathophysiological process.
© 2018 S. Karger AG, Basel.

Entities:  

Keywords:  Early preeclampsia; Late preeclampsia; Placental volume; Preeclampsia; Preeclampsia prediction models; Vascular indices

Mesh:

Year:  2018        PMID: 29393218     DOI: 10.1159/000481433

Source DB:  PubMed          Journal:  Fetal Diagn Ther        ISSN: 1015-3837            Impact factor:   2.587


  2 in total

1.  Evaluation of placental growth potential and placental bed perfusion by 3D ultrasound for early second-trimester prediction of preeclampsia.

Authors:  Hong Cui; Leilei Yu; Hua Li; Hongling Wang; Wenwen Liang; Huige Wang; Huifeng Wang
Journal:  J Assist Reprod Genet       Date:  2022-06-07       Impact factor: 3.357

2.  First trimester screening for pre-eclampsia and intrauterine growth restriction using three-dimensional Doppler angiography (SPIRIT): protocol for a multicentre prospective study in nulliparous pregnant women.

Authors:  Charline Bertholdt; Gabriela Hossu; Claire Banasiak; Marine Beaumont; Olivier Morel
Journal:  BMJ Open       Date:  2020-10-19       Impact factor: 2.692

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.