Literature DB >> 29384807

An Early Finding of Keratoconus: Increase in Corneal Densitometry.

Mustafa Koc1, Kemal Tekin2, Merve Inanc Tekin1, Mehmet Murat Uzel3, Pinar Kosekahya1, Kemal Ozulken4, Pelin Yilmazbas1.   

Abstract

PURPOSE: To investigate the corneal densitometry in subclinical keratoconus with normal elevation and pachymetric parameters.
METHODS: Patients with clinical keratoconus in one eye and subclinical keratoconus in the fellow eye were identified. The study group was selected from patients with subclinical keratoconus who showed normal results from topographic and Belin-Ambrósio Enhanced Ectasia Display III (BAD) analysis (Kmean <47.2 diopters, inferior-superior asymmetry <1.4 diopters, and KISA% <60%, elevation <5 μm, PPIaverage <1.06, PPImaximum <1.44, ARTaverage <414 μm, ARTmaximum <339 μm, and final D <1.6). The control group was selected from candidates for refractive surgery. The densitometric analyses were performed through the Pentacam HR (Oculus, Germany).
RESULTS: The medical records of 3474 patients with keratoconus were examined, and 116 (3.3%) subclinical keratoconus cases were detected. Normal BAD analysis results were obtained from 38 patients (1.1%). The control group also consisted of 38 patients. There were no significant differences between the eyes with subclinical keratoconus and those of the control in corrected distance visual acuity and topographic, topometric, and tomographic parameters (P > 0.05). In all layers of the 0- to 2-mm zone and in the anterior and central layers of the 0- to 6-mm zone, corneal densitometry was significantly higher in the subclinical keratoconus than the control (P < 0.001). In discriminating eyes with subclinical keratoconus from normal, the anterior layer in the 0- to 2-mm zone showed the highest area under the curve (0.883; cutoff: 19.7; sensitivity: 75%; specificity: 90%) in a receiver operating characteristic analysis.
CONCLUSIONS: The increase in densitometry in the central zone could be useful in detecting subclinical keratoconus.

Entities:  

Mesh:

Year:  2018        PMID: 29384807     DOI: 10.1097/ICO.0000000000001537

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  8 in total

1.  Evaluation of topographic, tomographic, topometric, densitometric, and aberrometric features of cornea with pentacam HR system in subclinical keratoconus.

Authors:  Haci Hasan Ozkan; Mustafa Koc; Hasan Kiziltoprak; Kemal Tekin; Emre Aydemir
Journal:  Int Ophthalmol       Date:  2021-03-27       Impact factor: 2.031

2.  Changes in the Optical Corneal Densitometry, Visual Acuity, and Refractive Error after the Annular Intracorneal Inlay Implantation.

Authors:  Mahmoud Jabbarvand; Mehdi Khodaparast; Alireza Jamali; Hooman Ahmadzadeh; Soodeh Bordbar
Journal:  J Curr Ophthalmol       Date:  2021-03-26

3.  Topography and Higher Order Corneal Aberrations of the Fellow Eye in Unilateral Keratoconus.

Authors:  Mustafa Koç; Kemal Tekin
Journal:  Turk J Ophthalmol       Date:  2018-10-31

4.  Effect of Down syndrome and keratoconus on corneal density and volume: a triple comparative study.

Authors:  Soheila Asgari; Mohammadreza Aghamirsalim; Shiva Mehravaran; Hassan Hashemi
Journal:  Sci Rep       Date:  2020-06-04       Impact factor: 4.379

5.  Corneal and lens densitometry in patients with vernal keratoconjunctivitis.

Authors:  Yusuf Cem Yılmaz; Sefik Can Ipek; Muhammet Derda Ozer
Journal:  Int Ophthalmol       Date:  2021-03-22       Impact factor: 2.031

6.  Changes in corneal densitometry after long-term orthokeratology for myopia and short-term discontinuation.

Authors:  Lianghui Zhao; Lili Jing; Jie Li; Xianli Du
Journal:  PLoS One       Date:  2022-02-04       Impact factor: 3.240

7.  Detection of subclinical keratoconus using a novel combined tomographic and biomechanical model based on an automated decision tree.

Authors:  Peng Song; Shengwei Ren; Yu Liu; Pei Li; Qingyan Zeng
Journal:  Sci Rep       Date:  2022-03-29       Impact factor: 4.379

8.  Influence of eye tilt on corneal densitometry.

Authors:  Alejandra Consejo; Marta Jiménez-García; Jos J Rozema; Ahmed Abass
Journal:  Ophthalmic Physiol Opt       Date:  2022-06-16       Impact factor: 3.992

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.