Vivienne Ng1, Jennifer Plitt1, David Biffar2. 1. University of Arizona, Department of Emergency Medicine, Tucson, Arizona. 2. University of Arizona, Arizona Simulation Technology & Education Center, Tucson, Arizona.
Abstract
INTRODUCTION: Peritonsillar abscess (PTA) is the most common deep space infection of the head and neck presenting to emergency departments.1 No commercial PTA task trainer exists for simulation training. Thus, resident physicians often perform their first PTA needle aspiration in the clinical setting, knowing that carotid artery puncture and hemorrhage are serious and devastating complications. While several low-fidelity PTA task trainers have been previously described, none allow for ultrasound image acquisition.6-9 We sought to create a cost-effective and realistic task trainer that allows trainees to acquire both diagnostic ultrasound and needle aspiration skills while draining a peritonsillar abscess. METHODS: We built the task trainer with low-cost, replaceable, and easily cleanable materials. A damaged airway headskin was repurposed to build the model. A mesh wire cylinder attached to a wooden base was fashioned to provide infrastructure. PTAs were simulated with a water and lotion solution inside a water balloon that was glued to the bottom of a paper cup. The balloon was fully submerged with ordnance gelatin to facilitate ultrasound image acquisition, and an asymmetric soft palate and deviated uvula were painted on top after setting. PTA cups were replaced after use. We spent eight hours constructing three task trainers and used 50 PTA cups for a total cost <$110. RESULTS: Forty-six emergency medicine (EM) residents performed PTA needle aspirations using the task trainers and were asked to rate ultrasound image realism, task trainer realism, and trainer ease of use on a five-point visual analog scale, with five being very realistic and easy. Sixteen of 46 (35%) residents completed the survey and reported that ultrasound images were representative of real PTAs (mean 3.41). They found the model realistic (mean 3.73) and easy to use (mean 4.08). Residents rated their comfort with the drainage procedure as 2.07 before and 3.64 after practicing on the trainer. CONCLUSION: This low-cost, easy-to-construct simulator allows for ultrasound image acquisition while performing PTA needle aspirations and is the first reported of its kind. Educators from EM and otolaryngology can use this model to educate inexperienced trainees, thus ultimately improving patient safety in the clinical setting.
INTRODUCTION: Peritonsillar abscess (PTA) is the most common deep space infection of the head and neck presenting to emergency departments.1 No commercial PTA task trainer exists for simulation training. Thus, resident physicians often perform their first PTA needle aspiration in the clinical setting, knowing that carotid artery puncture and hemorrhage are serious and devastating complications. While several low-fidelity PTA task trainers have been previously described, none allow for ultrasound image acquisition.6-9 We sought to create a cost-effective and realistic task trainer that allows trainees to acquire both diagnostic ultrasound and needle aspiration skills while draining a peritonsillar abscess. METHODS: We built the task trainer with low-cost, replaceable, and easily cleanable materials. A damaged airway headskin was repurposed to build the model. A mesh wire cylinder attached to a wooden base was fashioned to provide infrastructure. PTAs were simulated with a water and lotion solution inside a water balloon that was glued to the bottom of a paper cup. The balloon was fully submerged with ordnance gelatin to facilitate ultrasound image acquisition, and an asymmetric soft palate and deviated uvula were painted on top after setting. PTA cups were replaced after use. We spent eight hours constructing three task trainers and used 50 PTA cups for a total cost <$110. RESULTS: Forty-six emergency medicine (EM) residents performed PTA needle aspirations using the task trainers and were asked to rate ultrasound image realism, task trainer realism, and trainer ease of use on a five-point visual analog scale, with five being very realistic and easy. Sixteen of 46 (35%) residents completed the survey and reported that ultrasound images were representative of real PTAs (mean 3.41). They found the model realistic (mean 3.73) and easy to use (mean 4.08). Residents rated their comfort with the drainage procedure as 2.07 before and 3.64 after practicing on the trainer. CONCLUSION: This low-cost, easy-to-construct simulator allows for ultrasound image acquisition while performing PTA needle aspirations and is the first reported of its kind. Educators from EM and otolaryngology can use this model to educate inexperienced trainees, thus ultimately improving patient safety in the clinical setting.
Peritonsillar abscess (PTA) is the most common deep space infection of the head and neck presenting to emergency departments (ED).1 Draining a PTA is straightforward and can be accomplished with needle aspiration, incision and drainage, or tonsillectomy. With a cure rate of 93–95%,1 needle aspiration is the most common approach, does not require special equipment, and is relatively simple and inexpensive. However, physical exam alone has not been shown to reliably differentiate between PTA and cellulitis, and blind needle aspiration has a reported false negative rate of 10–24%.2–3 The addition of intraoral ultrasound can improve diagnosis (sensitivity 89–95%; specificity 79–100%)4 and aid in the safe performance of needle aspiration. In a prospective, randomized, controlled trial comparing the diagnostic accuracy of emergency providers for detecting PTA or cellulitis using intraoral ultrasound or landmark technique, ultrasound established the correct diagnosis more often and led to more successful aspiration of purulent material than landmark technique. Additionally, the average number of needle punctures was lower in the ultrasound than landmark group.5Currently, no commercial PTA task trainer exists for simulation training, and thus resident physicians often perform their first PTA needle aspiration in the clinical setting, with the knowledge that carotid artery puncture and hemorrhage are serious and devastating complications. Thus, simulating PTA needle aspirations with a realistic model that allows for ultrasound image acquisition and procedural competence can build confidence and proficiency prior to performing this procedure in patient care. While several low-fidelity PTA task trainers have been previously described,6–9 none allow for ultrasound-guided diagnosis and management, which is the preferred strategy in the ED setting for patient safety and comfort, and all have limitations ranging from ease and stability of construction to anatomic fidelity.
OBJECTIVES
We sought to create a cost-effective and realistic task trainer that allows trainees to acquire both diagnostic ultrasound and needle aspiration skills while draining a PTA.
PVC, polyvinyl chloride; NDS, national drainage system.
Prepare the headskin. Headskins with teeth and a tongue that are ready to be discarded from any airway task trainer or mannequin can be used.From the inside of the headskin, remove the trachea, bronchi, and any other anatomic parts until only the tongue and internal frame remain. Cut a slit at the base of the tongue to allow a craft stick to be slotted in and for zip-tie attachment to internal frame.Prepare the supportive stand (Figure 1a). The purpose is to provide structure to the floppy headskin while also allowing easy access to the posterior oropharynx through the mouth for the trainee and from the back for the facilitator.
Figure 1
(a) Supportive mesh cylinder from behind; (b) Finished peritonsillar abscess cup; (c) Peritonsillar abscess cup inserted into task trainer.
Cut hardware cloth to the height needed* to support the head in an upright position. Wrap hardware cloth around one 4” PVC sewer and drain fitting* to ensure fit. Two layers of cloth are suggested for added stability. Secure the mesh cylinder with the surplus bailing wire packaged with the hardware cloth.Using wire cutters, remove a posterior portion of the cylinder wide and high enough* for a facilitator to place and hold a PTA cup at the level of the mouth opening. Similarly, remove an anterior portion* of the cylinder to allow easy access to the PTA cup through the mouth. To prevent injury, use duct tape to cover the exposed metal edges.Position the 4” PVC sewer and drain fitting at the level of the base of the tongue*, aligning with the inferior aspect of the posterior and anterior openings, thus creating a platform on which the PTA cup is placed. Zip tie the drain fitting in place to the cylinder. Cap the top of the cylinder with one NDS 4” drain grate* to provide support to the top of the head and prevent bowing. Zip tie in place.Affix the cylinder to scrap plywood using utility hook hangers and screws, or similar. Secure the cylinder to the headskin’s internal frame with zip ties at multiple points, including through the slit made at the base of the tongue. This is crucial to maintaining an upright and anterior position of the PTA cup when the mouth is opened by the learner during the procedure. If desired, fill the cranial space above the cylinder with scrap foam or towels to provide structure to the head.Prepare the peritonsillar abscess (Figure 1b).Combine water and dimethicone barrier lotion to desired viscosity. Ensure simulated abscess material can be aspirated through an 18g spinal needle. Inject approximately 7ml of material into a small water balloon and tie closed.Glue the balloon to the bottom of an 8oz paper ice cream cup with cyanoacrylate glue. Mark the location of the PTA balloon on the underside of the cup.Tape half of a craft stick to the inside of the cup inferior to the abscess to ensure proper orientation in the airway head. Cover the balloon with a layer of cotton to obscure the balloon.Prepare ballistic gelatin. Combine 100g of gelatin powder per 800ml of water in a glass beaker and stir. Place beaker into heated water bath of at least 75C and allow to sit for a minimum of 10 minutes while stirring occasionally. Add approximately one drop each of red and yellow food coloring per 800ml to achieve desired flesh color. Using heat protective gloves or oven mitts, pour gelatin into the cup to cover both the balloon and cotton. Refrigerate for a minimum of two hours to fully set.Using red paint or moulage makeup, paint an asymmetric soft palate and deviated uvula on top of the gelatin, appropriately corresponding to the location of the balloon (Figure 1b).Model completion. Insert the craft stick from the PTA cup into the slit at the base of the tongue of the airway head. This stabilizes and correctly orients the cup during needle aspiration. Additionally, the facilitator is made aware of the PTA location, as indicated by the marking previously made on the underside of the cup (Figure 1c).
Construction
Approximately three hours were invested to build three task trainers, and an additional five hours were required to make 50 PTA cups.
IMPACT/EFFECTIVENESS
After a didactic session reviewing peritonsillar abscess presentation, treatment, and management, 46 EM residents performed PTA needle aspirations using the task trainers. Due to the airway headskin’s plastic material, naturally occurring trismus realistically simulated the difficulty in performing ultrasound-guided aspiration. Faculty instructors provided direct feedback on ultrasound technique and procedural skills.Residents were anonymously surveyed on their comfort performing PTA needle aspiration before and after the simulation session and were asked to rate ultrasound image realism, task trainer realism, and trainer ease of use on a five-point visual analog scale (VAS), with five being very realistic and easy. Sixteen of 46 (35%) residents completed the survey. Eleven had previously drained 1–3 PTAs in clinical practice, with the remaining five having no prior experience. On the VAS, residents rated their comfort with the PTA drainage procedure as 2.07 before and 3.64 after practicing the procedure on the trainer. Residents found that ultrasound images were representative of real PTAs (mean 3.41, range 2.4–4.7). They also reported that the task trainer was realistic (mean 3.73, range 2.5–4.8) and easy to use (mean 4.08, range 1.0–5.0).Our model, based upon that of Bunting et al., has several advantages over previous trainers including the incorporation of pork gelatin/hydrolysate to facilitate realistic ultrasound image acquisition with a fair and differentiable interface between the abscess and oropharynx (Figure 2) and improvements to the headskin infrastructure with the addition of a sturdy mesh cylinder and plywood base, allowing it to be mounted securely to any table. The improved stability allows the model to tolerate significant manipulation during the simulated procedure, including the forces applied to overcome trismus and used with an intraoral ultrasound probe while acquiring images of the abscess. The abscess itself is also compressible, and needle visibility and echogenicity are similar to that in real practice. Despite the time required to create this infrastructure, costs remain low; and once built, the task trainer can be adapted for different otolaryngologic procedures such as epistaxis management, tongue laceration repair, and post-tonsillectomy bleeding management. PTA cups can be made on demand for any learner group size.
Figure 2
Completed ultrasound-guided peritonsillar abscess task trainer and corresponding ultrasound image.
In summary, we developed a low-cost, do-it-yourself, and easy-to-construct simulator that allows for ultrasound image acquisition while performing peritonsillar abscess needle aspirations. Our trainees found the ultrasound images realistic and had increased understanding of and comfort with needle aspiration management after practicing on the model. To the best of our knowledge, we report the first ultrasound-guided peritonsillar abscess model for simulation training. Educators from EM and otolaryngology can use this model to educate inexperienced trainees, thus ultimately improving patient safety in the clinical setting. Future work on the trainer should focus on improving ultrasound image fidelity to include diagnostic characteristics felt important by the ultrasound community.
Authors: Hasan S Merali; Mark O Tessaro; Khushboo Q Ali; Shaun K Morris; Sajid B Soofi; Shabina Ariff Journal: BMC Pediatr Date: 2019-11-13 Impact factor: 2.125