Literature DB >> 29379001

Influence of blood contamination during multimode adhesive application on the microtensile bond strength to dentin.

E Kucukyilmaz1, E U Celik2, M Akcay1, B Yasa2.   

Abstract

OBJECTIVES: The present study evaluated the effects of blood contamination performed at different steps of bonding on the microtensile bond strength (μTBS) of multimode adhesives to dentin when using the self-etch approach.
MATERIALS AND METHODS: Seventy-five molars were randomly assigned to three adhesive groups comprising 25 specimens each: two multimode adhesives [Single Bond Universal (SBU) and All-Bond Universal (ABU)] and a conventional one-step self-etch adhesive [Clearfil S3 Bond Plus (CSBP)]. Each group was subdivided as follows: (1) uncontaminated (control): bonding application/light curing as a positive control; (2) contamination-1 (cont-1): bonding application/light curing/blood contamination/dry as a negative control; (3) contamination-2 (cont-2): bonding application/light curing/blood contamination/rinse/dry; (4) contamination-3 (cont-3): bonding application/blood contamination/dry/bonding re-application/light curing; and (5) contamination-4 (cont-4): bonding application/blood contamination/rinse/dry/bonding re-application/light curing. Dentin specimens were prepared for μTBS testing after the composite resin application. Data were analyzed with two-way ANOVA and post-hoc tests (α = 0.05).
RESULTS: μTBS values were similar in cont-3 groups, and ABU/cont-4 and corresponding control groups, but were significantly lower in the other groups than in their control groups (P < 0.05). Cont-1 groups showed the lowest μTBS values (P < 0.05).
CONCLUSIONS: Neither decontamination method prevented the decrease in μTBS when contamination occurred after light curing. Drying the blood contaminants and reapplying the adhesive may regain the dentin adhesion when contamination occurs before light curing. Alternatively, rinsing and drying contaminants followed by adhesive re-application may be effective depending on adhesive type.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29379001     DOI: 10.4103/1119-3077.224127

Source DB:  PubMed          Journal:  Niger J Clin Pract            Impact factor:   0.968


  2 in total

1.  Clinical performance of high-viscosity glass ionomer and resin composite on minimally invasive occlusal restorations performed without rubber-dam isolation: a two-year randomised split-mouth study.

Authors:  Hüseyin Hatirli; Bilal Yasa; Esra Uzer Çelik
Journal:  Clin Oral Investig       Date:  2021-03-08       Impact factor: 3.573

2.  Effect of hemostatic agent on microshear bond strength of total-etch and self-etch adhesive systems.

Authors:  Maryam Hoorizad; Haleh Heshmat; Tara Ansar Hosseini; Seyedeh Sara Kazemi; Seyedeh Farnaz Tabatabaei
Journal:  Dent Res J (Isfahan)       Date:  2019-11-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.