Literature DB >> 29373447

Does Posterior Fixation of Partially Unstable Open-Book Pelvic Ring Injuries Decrease Symphyseal Plate Failure? A Biomechanical Study.

Rachelle M Metz1, J Gary Bledsoe1,2, Berton R Moed1.   

Abstract

OBJECTIVE: Recent clinical study suggests an advantage to adding an iliosacral screw to the anterior fixation construct for anteroposterior compression type-2 (OTA/AO type 61-B1), partially unstable open-book pelvic ring injuries. Others have described stress examination to determine any required supplemental fixation. However, biomechanical studies investigating iliosacral fixation requirements for this injury are lacking. Our objective was to determine whether adding an iliosacral screw to symphyseal plate fixation decreases displacement in a well-defined open-book pelvic ring injury model.
METHODS: An open-book pelvic ring injury was created in 10 human cadaveric pelves by unilaterally releasing the sacrospinous, sacrotuberous, and anterior sacroiliac ligaments plus transection of the pubic symphysis, approximating the classically described anteroposterior compression type-2 (APC-2) injury. Specimens were divided into 2 groups: (1) symphyseal plating and (2) plating plus an iliosacral screw. Using a standard bilateral stance model loaded at 550 N, displacement measurements were obtained at 210,000 and 500,000 cycles.
RESULTS: Three specimens failed before 210,000 cycles because of technical errors and were excluded from analysis. For the remaining 7, there was no significant difference in displacement between the 2 groups, and none sustained implant failure. Post hoc analysis showed that a large sample size (45/group) would be required to detect any difference with 80% power, indicating a small effect size with limited clinical application.
CONCLUSIONS: Adding an iliosacral screw to the symphyseal plate fixation does not provide improved biomechanical outcome in classically described APC-2 injuries. Clinically, stress examination may be useful to determine the need for supplemental posterior fixation in APC-2 injuries.

Entities:  

Mesh:

Year:  2018        PMID: 29373447     DOI: 10.1097/BOT.0000000000001083

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  3 in total

1.  A biomechanics study on ligamentous injury in anterior-posterior compression type II pelvic injury.

Authors:  Jianzhong Kong; Yupeng Chu; Chengwei Zhou; Shuaibo Sun; Guodong Bao; Yu Xu; Xiaoshan Guo; Xiaolong Shui
Journal:  J Orthop Surg Res       Date:  2021-01-11       Impact factor: 2.359

2.  Fixation failure in patients with traumatic diastasis of pubic symphysis: impact of loss of reduction on early functional outcomes.

Authors:  Claudio Rojas; Ernesto Ewertz; Jose Miguel Hormazábal
Journal:  J Orthop Surg Res       Date:  2021-11-06       Impact factor: 2.359

3.  Biomechanical evaluation of seven fixation methods to treat pubic symphysis diastasis using finite element analysis.

Authors:  Yi-Quan Zheng; Li-Li Chen; Jia-Zuo Shen; Bing Gao; Xiao-Chuan Huang
Journal:  J Orthop Surg Res       Date:  2022-03-28       Impact factor: 2.359