| Literature DB >> 29354248 |
Mehdi Abed Kahnamouei1,2, Sarah Gholizadeh3, Sahand Rikhtegaran2, Mehdi Daneshpooy2, Soodabeh Kimyai2, Parnian Alizadeh Oskoee2, Yashar Rezaei2.
Abstract
Background. The aim of this study was to investigate the effect of preheating methacrylate- and silorane-based composite resins on their color stability up to 40 times at 55‒60°C. Methods. Seventy-six methacrylate and silorane-based composite resin samples, with a diameter of 10 mm and a height of 2 mm, were divided into 4 groups (n=19). After the samples were prepared, their color parameters were determined using a reflective spectrophotometer. The composite resin samples were separately stored in a solution of tea for 40 consecutive days. Then the samples underwent a color determination procedure again using a spectrophotometer and color changes were recorded. Finally two-way ANOVA was used to study the effect of composite temperature on its staining (P<0.05). Independent-samples t-test was used to evaluate changes in conversion rates of preheated composite resin samples compared to non-heated samples at P=0.005 and P=0.029 for silorane-based and Z250 composite resin samples, respectively. Results. Both composite resin type (P=0.014) and preheating (P<0.001) had significant effects on ΔE. Conclusion. Repeated preheating of methacrylate- and silorane-based composite resin samples, up to 55‒60°C for 40 rounds, resulted in more color changes compared with unheated composite resin samples. After storage in a solution of tea the color change rate in the composite resin samples of silorane-based was higher than the Z250 composite resin samples.Entities:
Keywords: Composite resin; color stability; microleakage; preheating
Year: 2017 PMID: 29354248 PMCID: PMC5768954 DOI: 10.15171/joddd.2017.039
Source DB: PubMed Journal: J Dent Res Dent Clin Dent Prospects ISSN: 2008-210X
The brands, manufacturers and chemical compositions of composites used in research
|
|
|
|
|
|
Filtek™ Z250 universal restorative : | 3M ESPE Dental Product U.S.A |
|
|
FiltekTM silorane –based composite: | 3M ESPE Dental Product U.S.A |
Means, standard deviations, and maximum and minimum values in both composite resin types before and after heating
|
|
|
|
|
| ||
|
| Heated | 19 | 14.9653 | 1.61799 | 12.03 | 17.81 |
| Unheated | 19 | 12.7253 | 2.19959 | 8.51 | 19.36 | |
|
| Heated | 19 | 13.3353 | 2.41234 | 10.14 | 18.96 |
| Unheated | 19 | 11.9847 | 1.89317 | 8.77 | 17.49 |
Two-way ANOVA to study the main effects of type of composite resin and heat and their cumulative effect on color changes (ΔE)
|
|
|
|
|
| 26.692 | .014 |
|
| 61.236 | .000 |
|
| 3.758 | .348 |
Figure 1
Figure 2Comparison of conversion rates between preheated and unheated composite resin samples
|
|
|
|
|
|
|
Heated 55‒60°C |
1.49±0/048 | 0.02 |
|
|
Heated 55‒60°C |
0.76±0/037 | 0.11 |