Studies in vitro of the relationship between ultrasound and laser Doppler velocimetry and applicability to the simplified Bernoulli relationship.

L M Valdes-Cruz, A P Yoganathan, T Tamura, F Tomizuka, Y R Woo, D J Sahn.   

Abstract

While there has been wide general acceptance of Doppler methods that use the simplified Bernoulii relationship to estimate pressure gradients across stenotic orifices, there is still ongoing controversy related to potential sources of error in the method. In this study we tested accuracy o ultrasound Doppler measurements of flow velocity when compared with the gold standard of laser light Doppler anemometry in a pulsatile flow model of pulmonic stenosis in vitro. We tested two commercially available Doppler systems and examined steered and nonsteered, parallel and off-axis and angle-corrected velocity determinations using continuous-wave and high-pulse repetition frequency (HPRF) methods. We also examined the potential range of error in the simplified Bernoulli method. One hundred and twenty individual flow states were examined with three stenotic valve orifices (3.0, 1.0, and 0.5 cm2 flow area) to measure velocities up to 620 cn/sec. A very high correlation coefficient was obtained for the comparison of laser Doppler anemometric and ultrasound velocity recordings by the nonsteered continuous-wave technique (r= .99, SEE = 17.9 cn/sec), but there was a tendency for underestimation of higher velocities when the transducer was positioned at 30 degrees and the ultrasound beam was steered so as to be parallel to the visualized flow jet (r = .98, SEE = 29.6 cn/sec). The HPRF ultrasound Doppler technique was also highly accurate in this optimized setting for measuring velocities (r = .99, SEE = 17 cm/sec), but also slightly underestimated the highest velocities. Our results also verified the accuracy of the simplified Bernoulli equation for converting instantaneous velocity measurements to estimated peak instantaneous gradient (r = .97, SEE = 8.4 mm Hg).

Entities:  

Mesh:

Year:  1986        PMID: 2935326     DOI: 10.1161/01.cir.73.2.300

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  5 in total

Review 1.  Quantitative applications of Doppler cardiography in congenital heart disease.

Authors:  S D Colan
Journal:  Cardiovasc Intervent Radiol       Date:  1987       Impact factor: 2.740

2.  Echocardiographic follow-up of children with supravalvular aortic stenosis.

Authors:  Ayse Guler Eroglu; Kadir Babaoglu; Funda Oztunc; Levent Saltik; Tevfik Demir; Güley Ahunbay; Alper Guzeltas; Gürkan Cetin
Journal:  Pediatr Cardiol       Date:  2006-11-07       Impact factor: 1.655

3.  Comparison of stenosis models for usage in the estimation of pressure gradient across aortic coarctation.

Authors:  Yubing Shi; Israel Valverde; Patricia V Lawford; Heynric B Grotenhuis; Philipp Beerbaum; D Rodney Hose
Journal:  J Biol Phys       Date:  2021-05-25       Impact factor: 1.560

4.  Functional assessment of bioprosthetic mitral valves by cardiovascular magnetic resonance: An in vitro validation and comparison to Doppler echocardiography.

Authors:  Dimitrios Maragiannis; Matthew S Jackson; Kyle Autry; Jose H Flores Arredondo; Constantina Aggeli; Dimitrios Tousoulis; William A Zoghbi; Dipan J Shah; Stephen H Little
Journal:  J Cardiovasc Magn Reson       Date:  2020-07-30       Impact factor: 5.364

5.  Towards Additive Manufacture of Functional, Spline-Based Morphometric Models of Healthy and Diseased Coronary Arteries: In Vitro Proof-of-Concept Using a Porcine Template.

Authors:  Rachel Jewkes; Hanna E Burton; Daniel M Espino
Journal:  J Funct Biomater       Date:  2018-02-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.