Development and clinical application of Vertebral Metrics: using a stereo vision system to assess the spine.

Ana Teresa Gabriel1, Cláudia Quaresma2, Mário Forjaz Secca2, Pedro Vieira3.   

Abstract

The biomechanical changes in the spinal column are considered to be the main responsible for rachialgia. Although radiological techniques use ionizing radiation, they are the most applied tools to assess the biomechanics of the spine. To face this problem, non-invasive techniques must be developed. Vertebral Metrics is an ionizing radiation-free instrument designed to detect the 3D position of each vertebrae in a standing position. Using a stereo vision system combined with low intensity UV light, recognition is achieved with software capable of distinguishing fluorescent marks. The fluorescent marks are the skin projection of the vertex of the spinal processes. This paper presents a major development of Vertebral Metrics and its evaluation. It performs a scan in less than 45 s with a resolution on the order of 1 mm, in each spatial direction, therefore, allowing an accurate analysis of the spine. The instrument was applied to patients without associated pathology. Statistically significant differences between consecutive scans were not found. A positive correlation between the 3D positions of each vertebra and the homologous position of the other vertebrae was observed. Using Vertebral Metrics, innovative results can be obtained. It can be used in areas such as orthopedics, neurosurgery, and rehabilitation. Graphical abstract ᅟ.

Entities:  

Keywords:  Biomechanics; Innovative; Medical device; Non-invasive; Spine

Mesh:

Year:  2018        PMID: 29352433     DOI: 10.1007/s11517-018-1789-0

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  18 in total

1.  Reliability and validity of the Metrecom Skeletal Analysis System in the assessment of sagittal plane lumbar angles.

Authors:  M Walsh; A C Breen
Journal:  Clin Biomech (Bristol, Avon)       Date:  1995-06       Impact factor: 2.063

2.  A new skin-surface device for measuring the curvature and global and segmental ranges of motion of the spine: reliability of measurements and comparison with data reviewed from the literature.

Authors:  Anne F Mannion; Katrin Knecht; Gordana Balaban; Jiri Dvorak; Dieter Grob
Journal:  Eur Spine J       Date:  2003-12-06       Impact factor: 3.134

3.  Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries.

Authors:  Amy Berrington de González; Sarah Darby
Journal:  Lancet       Date:  2004-01-31       Impact factor: 79.321

4.  Three-dimensional reconstruction and characterization of human external shapes from two-dimensional images using volumetric methods.

Authors:  Teresa C S Azevedo; João Manuel R S Tavares; Mário A P Vaz
Journal:  Comput Methods Biomech Biomed Engin       Date:  2010-06       Impact factor: 1.763

5.  Fast 3D reconstruction of the spine from biplanar radiographs using a deformable articulated model.

Authors:  Daniel C Moura; Jonathan Boisvert; Jorge G Barbosa; Hubert Labelle; João Manuel R S Tavares
Journal:  Med Eng Phys       Date:  2011-04-09       Impact factor: 2.242

6.  Palpation identification of spinous processes in the lumbar spine.

Authors:  Joanne C Harlick; Stephan Milosavljevic; Peter D Milburn
Journal:  Man Ther       Date:  2006-06-15

7.  Scoliometer measurements of patients with idiopathic scoliosis.

Authors:  Daniel M Coelho; Guilherme H Bonagamba; Anamaria S Oliveira
Journal:  Braz J Phys Ther       Date:  2013 Mar-Apr       Impact factor: 3.377

8.  The reliability and validity of three non-radiological measures of thoracic kyphosis and their relations to the standing radiological Cobb angle.

Authors:  G A Greendale; N S Nili; M-H Huang; L Seeger; A S Karlamangla
Journal:  Osteoporos Int       Date:  2010-10-12       Impact factor: 4.507

Review 9.  The quality of evidence of psychometric properties of three-dimensional spinal posture-measuring instruments.

Authors:  Yolandi Brink; Quinette Louw; Karen Grimmer-Somers
Journal:  BMC Musculoskelet Disord       Date:  2011-05-13       Impact factor: 2.362

10.  Development of a stereo vision measurement system for a 3D three-axial pneumatic parallel mechanism robot arm.

Authors:  Mao-Hsiung Chiang; Hao-Ting Lin; Chien-Lun Hou
Journal:  Sensors (Basel)       Date:  2011-02-21       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.