Literature DB >> 29346113

Uncertainty in Limb Configuration Makes Minimal Contribution to Errors Between Observed and Predicted Forces in a Musculoskeletal Model of the Rat Hindlimb.

Qi Wei, Dinesh K Pai, Matthew C Tresch.   

Abstract

Subject-specific musculoskeletal models are increasingly used in biomedical applications to predict endpoint forces due to muscle activation, matching predicted forces to experimentally observed forces at a specific limb configuration. However, it is difficult to precisely measure the limb configuration at which these forces are observed. The consequent uncertainty in limb configuration might contribute to errors in model predictions. We therefore evaluated how uncertainties in limb configuration measurement contributed to errors in force prediction, using data from in vivo measurements in the rat hindlimb. We used a data-driven approach to estimate the uncertainty in estimated limb configuration and then used this configuration uncertainty to evaluate the consequent uncertainty in force predictions, using Monte Carlo simulations. We used subject-specific models of joint structures (i.e., centers and axes of rotation) in order to estimate limb configurations for each animal. The standard deviation of the distribution of predicted force directions resulting from configuration uncertainty was small, ranging between 0.27° and 3.05° across muscles. For most muscles, this standard deviation was considerably smaller than the error between observed and predicted forces (between 0.57° and 70.96°), suggesting that uncertainty in limb configuration could not explain inaccuracies in model predictions. Instead, our results suggest that inaccuracies in muscle model parameters, most likely in parameters specifying muscle moment arms, are the main source of prediction errors by musculoskeletal models in the rat hindlimb.

Entities:  

Mesh:

Year:  2018        PMID: 29346113      PMCID: PMC5954989          DOI: 10.1109/TBME.2017.2775598

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  25 in total

1.  Towards a realistic biomechanical model of the thumb: the choice of kinematic description may be more critical than the solution method or the variability/uncertainty of musculoskeletal parameters.

Authors:  Francisco J Valero-Cuevas; M Elise Johanson; Joseph D Towles
Journal:  J Biomech       Date:  2003-07       Impact factor: 2.712

2.  Transducer and base compliance alter the in situ 6 dof force measured from muscle during an isometric contraction in a multi-joint limb.

Authors:  Thomas G Sandercock; Sang Hoon Yeo; Dinesh K Pai; Matthew C Tresch
Journal:  J Biomech       Date:  2012-02-02       Impact factor: 2.712

3.  A model of the upper extremity for simulating musculoskeletal surgery and analyzing neuromuscular control.

Authors:  Katherine R S Holzbaur; Wendy M Murray; Scott L Delp
Journal:  Ann Biomed Eng       Date:  2005-06       Impact factor: 3.934

4.  Monte Carlo simulation of a planar shoulder model.

Authors:  R E Hughes; K N An
Journal:  Med Biol Eng Comput       Date:  1997-09       Impact factor: 2.602

5.  Computational Models for Neuromuscular Function.

Authors:  Francisco J Valero-Cuevas; Heiko Hoffmann; Manish U Kurse; Jason J Kutch; Evangelos A Theodorou
Journal:  IEEE Rev Biomed Eng       Date:  2009

6.  Extrapolatable analytical functions for tendon excursions and moment arms from sparse datasets.

Authors:  Manish U Kurse; Hod Lipson; Francisco J Valero-Cuevas
Journal:  IEEE Trans Biomed Eng       Date:  2012-03-05       Impact factor: 4.538

7.  Quantification of fingertip force reduction in the forefinger following simulated paralysis of extensor and intrinsic muscles.

Authors:  F J Valero-Cuevas; J D Towles; V R Hentz
Journal:  J Biomech       Date:  2000-12       Impact factor: 2.712

8.  Three-dimensional kinematics of the pelvis and hind limbs in chimpanzee (Pan troglodytes) and human bipedal walking.

Authors:  Matthew C O'Neill; Leng-Feng Lee; Brigitte Demes; Nathan E Thompson; Susan G Larson; Jack T Stern; Brian R Umberger
Journal:  J Hum Evol       Date:  2015-07-17       Impact factor: 3.895

9.  Improving the fitness of high-dimensional biomechanical models via data-driven stochastic exploration.

Authors:  Veronica J Santos; Carlos D Bustamante; Francisco J Valero-Cuevas
Journal:  IEEE Trans Biomed Eng       Date:  2008-10-07       Impact factor: 4.538

10.  Scaling of muscle architecture and fiber types in the rat hindlimb.

Authors:  Carolyn M Eng; Laura H Smallwood; Maria Pia Rainiero; Michele Lahey; Samuel R Ward; Richard L Lieber
Journal:  J Exp Biol       Date:  2008-07       Impact factor: 3.312

View more
  1 in total

1.  Vastus lateralis and vastus medialis produce distinct mediolateral forces on the patella but similar forces on the tibia in the rat.

Authors:  Thomas G Sandercock; Qi Wei; Yasin Y Dhaher; Dinesh K Pai; Matthew C Tresch
Journal:  J Biomech       Date:  2018-09-13       Impact factor: 2.712

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.