Literature DB >> 29342060

Creep and Wear in Vitamin E-Infused Highly Cross-Linked Polyethylene Cups for Total Hip Arthroplasty: A Prospective Randomized Controlled Trial.

G Rochcongar1, G Buia1, E Bourroux1, J Dunet1, V Chapus1, C Hulet1.   

Abstract

BACKGROUND: Aseptic loosening, the most common indication for revision surgery in total hip arthroplasty, can result from osteolysis caused by polyethylene (PE) wear particles. PE wear is increased by age-related oxidation of PE and free radicals emerging during irradiation cross-linking. Diffusion of vitamin E into PE stabilizes free radicals to maintain the biomechanical properties of PE. The purpose of this study was to determine whether vitamin E-infused highly cross-linked PE cups could reduce wear rates.
METHODS: We performed a prospective randomized controlled trial, in which 62 patients were allocated to 2 groups: a study group that received a vitamin E-infused highly cross-linked PE (HXLPE/VitE) cup and a control group that received an ultra-high molecular weight PE (UHMWPE) cup. Using radiostereometric analysis, we measured the penetration of the femoral head into the cup 7 days after surgery (baseline) and then again at 6 months and at 1, 2, and 3 years later.
RESULTS: Baseline variables did not differ significantly between the groups. At 1, 2, and 3 years after surgery, the HXLPE/VitE cup showed significantly less cumulative penetration (creep and wear) than the UHMWPE cup (p = 0.004, p < 0.0001, and p < 0.0001, respectively). The cumulative penetration after 3 years was 0.200 mm for the HXLPE/VitE cup versus 0.317 mm for the UHMWPE cup (p < 0.0001). From 1 to 3 years after surgery, after creep had stabilized and further penetration was mainly due to wear, the mean penetration increased only 0.04 mm in the HXLPE/VitE cup and 0.116 mm in the UHMWPE cup.
CONCLUSIONS: Our results confirm that wear rates over the first 3 years following surgery were lower in HXLPE/VitE cups than in UHMWPE cups. This suggests that HXLPE/VitE cups may prevent osteolysis, implant loosening, and eventually revision surgery. Long-term follow-up data continue to be collected to confirm these findings. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29342060     DOI: 10.2106/JBJS.16.01379

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  9 in total

1.  Wear Rates of XLPE Nearly 50% Lower Than Previously Thought After Adjusting for Initial Creep: An RCT Comparing 4 Bearing Combinations.

Authors:  Amir Khoshbin; James Wu; Sarah Ward; Luana T Melo; Emil H Schemitsch; James P Waddell; Amit Atrey
Journal:  JB JS Open Access       Date:  2020-06-05

2.  Does Activity Level After Primary Total Hip Arthroplasty Affect Aseptic Survival?

Authors:  David A Crawford; Joanne B Adams; Gerald R Hobbs; Michael J Morris; Keith R Berend; Adolph V Lombardi
Journal:  Arthroplast Today       Date:  2021-08-23

3.  Implant survival of 2,723 vitamin E-infused highly crosslinked polyethylene liners in total hip arthroplasty: data from the Finnish Arthroplasty Register.

Authors:  Matias Hemmilä; Inari Laaksonen; Markus Matilainen; Antti Eskelinen; Jaason Haapakoski; Ari-Pekka Puhto; Jukka Kettunen; Konsta Pamilo; Keijo T Mäkelä
Journal:  Acta Orthop       Date:  2021-02-01       Impact factor: 3.717

4.  The concept of a cementless isoelastic monoblock cup made of highly cross-linked polyethylene infused with vitamin E: radiological analyses of migration and wear using EBRA and clinical outcomes at mid-term follow-up.

Authors:  Yama Afghanyar; Sebastian Joser; Jonas Tecle; Philipp Drees; Jens Dargel; Philipp Rehbein; Karl Philipp Kutzner
Journal:  BMC Musculoskelet Disord       Date:  2021-01-23       Impact factor: 2.362

5.  Vitamin E-Enhanced Liners in Primary Total Hip Arthroplasty: A Systematic Review and Meta-Analysis.

Authors:  Qian-Yue Cheng; Bin-Fei Zhang; Peng-Fei Wen; Jun Wang; Lin-Jie Hao; Tao Wang; Hui-Guang Cheng; Ya-Kang Wang; Jian-Bin Guo; Yu-Min Zhang
Journal:  Biomed Res Int       Date:  2021-12-06       Impact factor: 3.411

6.  A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients.

Authors:  Julie R A Massier; Joost H J Van Erp; Thom E Snijders; Arthur DE Gast
Journal:  Acta Orthop       Date:  2020-08-24       Impact factor: 3.717

7.  2-year results of an RCT of 2 uncemented isoelastic monoblock acetabular components: lower wear rate with vitamin E blended highly cross-linked polyethylene compared to ultra-high molecular weight polyethylene.

Authors:  Joost H J van Erp; Julie R A Massier; Jelle J Halma; Thom E Snijders; Arthur de Gast
Journal:  Acta Orthop       Date:  2020-02-26       Impact factor: 3.717

8.  Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled RSA trial with 5-year follow-up.

Authors:  Halldor Bergvinsson; Vasilis Zampelis; Martin Sundberg; Jon Tjörnstrand; Gunnar Flivik
Journal:  Acta Orthop       Date:  2022-01-20       Impact factor: 3.717

Review 9.  Overview of Randomized Controlled Trials in Primary Total Hip Arthroplasty (34,020 Patients): What Have We Learnt?

Authors:  Hosam E Matar; Simon R Platt; Tim N Board; Martyn L Porter
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2020-08
  9 in total