Biomechanical Comparison of Different Implant Inclinations and Cantilever Lengths in All-on-4 Treatment Concept by Three-Dimensional Finite Element Analysis.

Oguz Ozan, Sevcan Kurtulmus-Yilmaz.   

Abstract

PURPOSE: The aim of this study was to evaluate the effect of implant inclination and cantilever length on the stress distribution in mandibular cortical bone, implant, abutment, prosthetic framework, and prosthetic screw via three-dimensional (3D) finite element analysis (FEA).
MATERIALS AND METHODS: Four different finite element models (0-0, 17-17, 30-30, 45-30) were designed according to the tilting angle (0, 17, 30, and 45 degrees) of the posterior implant and angle of multiunit abutments (0, 17, and 30 degrees). Screw-retained fixed prostheses with different cantilever lengths in accordance with implant inclination were modeled. A foodstuff was used for the 100-N load application. Maximum principal (Pmax) and minimum principal (Pmin) stresses were calculated for cortical bone, and von Mises stress values were calculated for the implant, abutment, metal framework, and prosthetic screw.
RESULTS: The highest stress values were observed in the anterior implant, surrounding bone, and prosthetic components of the 0-0 configuration. Pmin stress values in bone were gradually decreased with the increasing inclination of both anterior and posterior implants. Peak Pmax stress values were detected in the 0-0 group. For the cortical bone around the posterior implant, the 30-30 group showed the lowest Pmax value. The highest von Mises stress on implants was found at the posterior implant of the 30-30 group. The stress values on abutments gradually decreased with the increase of the angulation of the posterior implants. For prosthetic screws, the 30-30 and 45-30 groups exhibited lower stress values, and for the metal framework, the 30-30 group exhibited lower stress values.
CONCLUSION: Biomechanical comparison via 3D FEA revealed that decreasing the cantilever length by tilting the posterior implants resulted in a reduction in stress values in the peri-implant bone, abutment, prosthetic screw, and metal framework. The groups with 30- and 45-degree tilted posterior implants and shorter cantilever lengths showed better stress distributions in comparison to the straight and 17-degree tilted groups.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29340344     DOI: 10.11607/jomi.6201

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  9 in total

1.  Bone quality effect on short implants in the edentulous mandible: a finite element study.

Authors:  Chaowei Liu; Yifeng Xing; Yan Li; Yanjun Lin; Jianghan Xu; Dong Wu
Journal:  BMC Oral Health       Date:  2022-04-26       Impact factor: 3.747

2.  Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study.

Authors:  Ahmed Mostafa Abdelfattah Mohamed; Mohamed Gamal Askar; Mahmoud El-Moutassim Bellah El Homossany
Journal:  BMC Oral Health       Date:  2022-05-22       Impact factor: 3.747

3.  Effects of Different Positions and Angles of Implants in Maxillary Edentulous Jaw on Surrounding Bone Stress under Dynamic Loading: A Three-Dimensional Finite Element Analysis.

Authors:  Xiaqing Liu; Fang Pang; Ying Li; Hui Jia; Xiaohua Cui; Yuan Yue; Xuelian Yang; Qi Yang
Journal:  Comput Math Methods Med       Date:  2019-12-17       Impact factor: 2.238

4.  Principles of biomechanics in oral implantology.

Authors:  Avram Manea; Simion Bran; Cristian Dinu; Horatiu Rotaru; Ioan Barbur; Bogdan Crisan; Gabriel Armencea; Florin Onisor; Madalina Lazar; Daniel Ostas; Mihaela Baciut; Sergiu Vacaras; Ileana Mitre; Liana Crisan; Ovidiu Muresan; Rares Roman; Grigore Baciut
Journal:  Med Pharm Rep       Date:  2019-12-15

5.  In-vitro fatigue and fracture performance of three different ferrulized implant connections used in fixed prosthesis.

Authors:  Saverio Cosola; Paolo Toti; Enrico Babetto; Ugo Covani; Miguel Peñarrocha-Diago; David Peñarrocha-Oltra
Journal:  J Dent Sci       Date:  2020-08-27       Impact factor: 2.080

6.  Crestal bone stability after flapless placement of sloped implants with immediate temporization in edentulous mandible. A prospective comparative clinical trial.

Authors:  Algirdas Puisys; Viktorija Auzbikaviciute; Egle Vindasiute-Narbute; Saulius Zukauskas; Kestutis Vaicekauskas; Dainius Razukevicus
Journal:  Clin Exp Dent Res       Date:  2020-11-30

7.  Three-Dimensional Biomechanical Finite Element Analysis of Lumbar Disc Herniation in Middle Aged and Elderly.

Authors:  Shiyuan Wan; Bin Xue; Yanhao Xiong
Journal:  J Healthc Eng       Date:  2022-01-15       Impact factor: 2.682

8.  Enhanced perfusion of elliptical wound closures using a novel adhesive suture retention device.

Authors:  Allison Stoecker; William Lear; Karsten Johnson; Jared Bahm; Jamie J Kruzic
Journal:  Health Sci Rep       Date:  2021-09-14

9.  Fracture Resistance of CAD/CAM Implant-Supported 3Y-TZP-Zirconia Cantilevers: An In Vitro Study.

Authors:  Mariana Novais; António Sérgio Silva; Joana Mendes; Pedro Barreiros; Carlos Aroso; José Manuel Mendes
Journal:  Materials (Basel)       Date:  2022-09-24       Impact factor: 3.748

  9 in total