Literature DB >> 29334778

Fluid Dynamic Analysis of Hand-Pump Infuser and UROMAT Endoscopic Automatic System for Irrigation Through a Flexible Ureteroscope.

Daniel J Lama1, Michael Owyong1, Egor Parkhomenko1, Roshan M Patel1, Jaime Landman1, Ralph V Clayman1.   

Abstract

INTRODUCTION: To evaluate the flow characteristics produced by a manual and automated-pump irrigation system connected to a flexible ureteroscope.
MATERIALS AND METHODS: An in vitro analysis of a manual hand-pump infuser (HP) and the UROMAT Endoscopic Automatic System for Irrigation® (E.A.S.I.) pump was performed. Standard irrigation tubing was used to connect a three-way valve to a flexible ureteroscope, the irrigation system, and a digital manometer. Flow rate and irrigation pressure measurements were recorded over a 15-minute period using pressure settings of 150 and 200 mm Hg for both irrigation pump systems. Once the HP was inflated to the initial pressure, it was not reinflated over the course of the trial. Data were collected with the working channel unoccupied and with placement of a 200 μm (0.6F) holmium laser fiber, 1.7F nitinol stone retrieval basket, or 2.67F guidewire.
RESULTS: The difference in pressure measured at the site of inflow of irrigation to the ureteroscope was significantly greater using the HP compared to the E.A.S.I. pump at pressure settings of 150 mm Hg with and without the use of ureteroscopic instrumentation (p < 0.001), and at 200 mm Hg with instrumentation in the working channel (p < 0.01). There was no significant difference in the flow rate of irrigation through the open-channel ureteroscope over the course of 5 minutes between the two pump systems.
CONCLUSION: The flow rates of irrigation produced by the HP and the E.A.S.I. pump are similar at pressures of 150 and 200 mm Hg irrespective of the occupancy of a ureteroscope's working channel during the first 5-minutes of irrigation. Irrigation pressure at the entry site of the ureteroscope is subject to significant variability with use of the HP compared to the E.A.S.I. pump irrigation system.

Entities:  

Keywords:  flexible ureteroscope; flow; irrigation; pressure

Mesh:

Year:  2018        PMID: 29334778     DOI: 10.1089/end.2017.0811

Source DB:  PubMed          Journal:  J Endourol        ISSN: 0892-7790            Impact factor:   2.942


  3 in total

Review 1.  To start or not: Factors to consider when implementing routine probiotic use in the NICU.

Authors:  Maria E Barbian; Rachel Buckle; Patricia Wei Denning; Ravi Mangal Patel
Journal:  Early Hum Dev       Date:  2019-06-10       Impact factor: 2.079

2.  Prospective Randomized Comparison of Standard Hand Pump Infuser Irrigation vs an Automated Irrigation Pump During Percutaneous Nephrolithotomy and Ureteroscopy: Assessment of Operating Room Efficiency and Surgeon Satisfaction.

Authors:  Francis A Jefferson; John M Sung; Luke Limfueco; Sherry Lu; Courtney M Cottone; Shlomi Tapiero; Roshan M Patel; Ralph V Clayman; Jaime Landman
Journal:  J Endourol       Date:  2019-11-20       Impact factor: 2.942

Review 3.  Retrograde intrarenal surgery: Past, present, and future.

Authors:  Takaaki Inoue; Shinsuke Okada; Shuzo Hamamoto; Masato Fujisawa
Journal:  Investig Clin Urol       Date:  2021-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.