Eva Klapkova1, Jana Cepova1, Katerina Dunovska1, Richard Prusa1. 1. Department of Medical Chemistry and Clinical Biochemistry, Charles University, 2nd Faculty of Medicine and University Hospital Motol, Prague, Czech Republic.
Abstract
BACKGROUND: New high-performance liquid chromatography (HPLC) method was developed for the determination of vitamin K1 and two forms of vitamin K2 (MK-4 and MK-7) in human serum, and the levels of vitamin K were determined in 350 samples of postmenopausal women. METHODS: Vitamin K was determined by HPLC with fluorescence detection after postcolumn zinc reduction. The detection was performed at 246 nm (excitation) and 430 nm (emission). The internal standard and 2 mL of ethanol were added to 500 μL of serum. The mixture was extracted with 4 mL of hexane, and solid phase extraction was then used. RESULTS: The HLPC method was fully validated. The intra- and interday accuracy and precision were evaluated on two QC samples by multiple analysis, and CV were less than 10%. The limit of quantification for MK-4 was found at 0.04 ng/mL, for K1 0.03 ng/mL, and for MK-7 0.03 ng/mL. The mean recoveries of the corresponding compounds were 98%-110%. Serum levels of MK-4, K1 , and MK-7 in postmenopausal women with osteoporosis were 0.890 ± 0.291 ng/mL, 0.433 ± 0.394 ng/mL, and 1.002 ± 1.020 ng/mL, respectively (mean ± SD). Serum levels of MK-4, K1 , and MK-7 in postmenopausal women without osteoporosis were 0.825 ± 0.266 ng/mL, 0.493 ± 0.399 ng/mL, and 1.186 ± 1.076 ng/mL, respectively (mean ± SD). CONCLUSION: New HPLC method for the determination of vitamins K1 , MK-4, and MK-7 in serum was evaluated and validated. This method is highly specific and sensitive with the low limit of quantification.
BACKGROUND: New high-performance liquid chromatography (HPLC) method was developed for the determination of vitamin K1 and two forms of vitamin K2 (MK-4 and MK-7) in human serum, and the levels of vitamin K were determined in 350 samples of postmenopausal women. METHODS:Vitamin K was determined by HPLC with fluorescence detection after postcolumn zinc reduction. The detection was performed at 246 nm (excitation) and 430 nm (emission). The internal standard and 2 mL of ethanol were added to 500 μL of serum. The mixture was extracted with 4 mL of hexane, and solid phase extraction was then used. RESULTS: The HLPC method was fully validated. The intra- and interday accuracy and precision were evaluated on two QC samples by multiple analysis, and CV were less than 10%. The limit of quantification for MK-4 was found at 0.04 ng/mL, for K1 0.03 ng/mL, and for MK-7 0.03 ng/mL. The mean recoveries of the corresponding compounds were 98%-110%. Serum levels of MK-4, K1 , and MK-7 in postmenopausal women with osteoporosis were 0.890 ± 0.291 ng/mL, 0.433 ± 0.394 ng/mL, and 1.002 ± 1.020 ng/mL, respectively (mean ± SD). Serum levels of MK-4, K1 , and MK-7 in postmenopausal women without osteoporosis were 0.825 ± 0.266 ng/mL, 0.493 ± 0.399 ng/mL, and 1.186 ± 1.076 ng/mL, respectively (mean ± SD). CONCLUSION: New HPLC method for the determination of vitamins K1 , MK-4, and MK-7 in serum was evaluated and validated. This method is highly specific and sensitive with the low limit of quantification.
Authors: Laura Y Wang; Chris J Bates; Liya Yan; Dominic J Harrington; Martin J Shearer; Ann Prentice Journal: Clin Chim Acta Date: 2004-09 Impact factor: 3.786
Authors: R Flore; F R Ponziani; T A Di Rienzo; M A Zocco; A Flex; L Gerardino; A Lupascu; L Santoro; A Santoliquido; E Di Stasio; E Chierici; A Lanti; P Tondi; A Gasbarrini Journal: Eur Rev Med Pharmacol Sci Date: 2013-09 Impact factor: 3.507