M Margarida Castel-Branco1, Ana Fontes2, Isabel V Figueiredo3.
Abstract
BACKGROUND: A correct selection of drugs prescribed, but also the choice of the appropriate inhaler device, is crucial for the control of respiratory diseases.Entities:
Keywords: Asthma; Chronic Obstructive; Health Care; Nebulizers and Vaporizers; Patient Education as Topic; Pharmacies; Pharmacists; Portugal; Pulmonary Disease; Quality Assurance
Year: 2017 PMID: 29317923 PMCID: PMC5742000 DOI: 10.18549/PharmPract.2017.04.1072
Source DB: PubMed Journal: Pharm Pract (Granada) ISSN: 1885-642X
Sample characteristics.
| n (%) | |
|---|---|
| Gender | |
| Male | 34 (50.7) |
| Female | 33 (49.3) |
| Age (years) | |
| 18-24 | 3 (4.5) |
| 25-44 | 8 (11.9) |
| 45-64 | 14 (20.9) |
| 65-74 | 17 (25.4) |
| 75 and over | 25 (37.3) |
| Disease | |
| Asthma | 25 (37.3) |
| COPD | 42 (62.7) |
| Number of inhalers | |
| 1 | 44 (65.7) |
| 2 | 19 (28.4) |
| 3 | 3 (4.5) |
| 4 | 1 (1.5) |
| Types of inhaler | |
| 1 | 47 (70.1) |
| 2 | 18 (26.9) |
| 3 | 2 (3.0) |
COPD - Chronic Obstructive Pulmonary Disease.
Relative frequencies of all types of inhaler devices presented on the 95 evaluated inhalation techniques.
| n (%) | |
|---|---|
| pMDI | 16 (16.8%) |
| pMDI-spacer | 2 (2.1%) |
| SMI | 2 (2.1%) |
| DPI | |
| Aerolizer® | 6 (6.3%) |
| Breezhaler® | 8 (8.4%) |
| Handihaler® | 4 (4.2%) |
| Diskus® | 32 (33.7%) |
| Ellipta® | 2 (2.1%) |
| Genuair® | 2 (2.1%) |
| Novolizer® | 1 (1.1%) |
| Spiromax® | 1 (1.1%) |
| Turbohaler® | 19 (20.0%) |
DPI - Dry Powder Inhaler; pMDI - pressurized Metered Dose Inhaler; SMI - Soft Mist Inhaler
Errors identified in all inhalation techniques (n=95).
| Error (n (%)) | DPI (n=75) | pMDI (n=16) | pMDI-spacer (n=2) | SMI (n=2) |
|---|---|---|---|---|
| Failure to pierce capsule (n=18) | 3 (16.7%) | - | - | - |
| Error in dose activation with multiple dose DPI (n=57) | 8 (14.0%) | - | - | - |
| Not breathing out gently away before inhalation | 46 (61.3%) | 8 (50.0%) | - | 1 (50.0%) |
| Inhalation too slow | 25 (33.3%) | - | - | - |
| Not holding breath for about 10 seconds after inhalation | 51 (68.0%) | 10 (62.5%) | - | 2 (100.0%) |
| Not replacing the cap after inhalation (n=57) | 2 (3.5%) | - | - | - |
| Not shaking the device before inhalation | - | 6 (37.5%) | 0 (0.0%) | - |
| Failure to make tight seal with lips | - | 3 (18.8%) | - | - |
| Failure to synchronize inhalation with device actuation | - | 7 (43.8%) | - | - |
| Not use mask or mouthpiece well adapted | - | - | 0 (0.0%) | - |
| Not perform 10 inhalations in tidal volume | - | - | 0 (0.0%) | - |
| Not properly rotating the transparent base with SMI | - | - | - | 1 (50.0%) |
| Not pressing the dose release button with SMI | - | - | - | 1 (50.0%) |
| No errors | 13 (17.3%) | 1 (6.3%) | 2 (100.0%) | 0 (0.0%) |