Literature DB >> 29303558

21 Tesla FT-ICR Mass Spectrometer for Ultrahigh-Resolution Analysis of Complex Organic Mixtures.

Donald F Smith1, David C Podgorski1,2, Ryan P Rodgers1,3, Greg T Blakney1, Christopher L Hendrickson1,3.   

Abstract

We describe complex organic mixture analysis by 21 tesla (T) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Ultrahigh mass-resolving power (m/Δm50% > 2 700 000 at m/z 400) and mass accuracy (80 ppb rms) enable resolution and confident identification of tens of thousands of unique elemental compositions. We demonstrate 2.2-fold higher mass-resolving power, 2.6-fold better mass measurement accuracy, and 1.3-fold more assigned molecular formulas compared to our custom-built, state-of-the-art 9.4 T FT-ICR mass spectrometer for petroleum and dissolved organic matter (DOM) analyses. Analysis of a heavy petroleum distillate exemplifies the need for ultrahigh-performance mass spectrometry (49 040 assigned molecular formulas for 21 T versus 29 012 for 9.4 T) and extends the identification of previously unresolved Oo, SsOo, and NOo classes. Mass selective ion accumulation (20 Thompson isolation) of an asphalt volcano sample yields 462 resolved mass spectral peaks at m/z 677 and reveals previously unresolved CcHhNnOoSs mass differences at high mass (m/z > 600). Similar performance gains are realized in the analysis of dissolved organic matter, where doubly charged Oo species are resolved from singly charged SOo species, which requires a mass-resolving power greater than 1 400 000 (at m/z 600). This direct comparison reveals the continued need for higher mass-resolving power and better mass accuracy for comprehensive molecular characterization of the most complex organic mixtures.

Year:  2018        PMID: 29303558     DOI: 10.1021/acs.analchem.7b04159

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  21 in total

Review 1.  New mass spectrometry technologies contributing towards comprehensive and high throughput omics analyses of single cells.

Authors:  Sneha P Couvillion; Ying Zhu; Gabe Nagy; Joshua N Adkins; Charles Ansong; Ryan S Renslow; Paul D Piehowski; Yehia M Ibrahim; Ryan T Kelly; Thomas O Metz
Journal:  Analyst       Date:  2019-01-28       Impact factor: 4.616

2.  High-Resolution Mass Spectrometry Identification of Novel Surfactant-Derived Sulfur-Containing Disinfection Byproducts from Gas Extraction Wastewater.

Authors:  Hannah K Liberatore; Danielle C Westerman; Joshua M Allen; Michael J Plewa; Elizabeth D Wagner; Amy M McKenna; Chad R Weisbrod; James P McCord; Richard J Liberatore; David B Burnett; Leslie H Cizmas; Susan D Richardson
Journal:  Environ Sci Technol       Date:  2020-07-17       Impact factor: 9.028

3.  A Miniaturized Fourier Transform Electrostatic Linear Ion Trap Mass Spectrometer: Mass Range and Resolution.

Authors:  Joshua T Johnson; Kenneth W Lee; Jay S Bhanot; Scott A McLuckey
Journal:  J Am Soc Mass Spectrom       Date:  2019-02-12       Impact factor: 3.109

4.  Diagnosis of hemoglobinopathy and β-thalassemia by 21-Tesla Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Jae-Seok Kim; Hyun Sik Kim
Journal:  Ann Transl Med       Date:  2019-09

Review 5.  Applications and continued evolution of glycan imaging mass spectrometry.

Authors:  Colin T McDowell; Xiaowei Lu; Anand S Mehta; Peggi M Angel; Richard R Drake
Journal:  Mass Spectrom Rev       Date:  2021-08-15       Impact factor: 10.946

Review 6.  Metabolomics: Going Deeper, Going Broader, Going Further.

Authors:  Sofia Moco; Joerg M Buescher
Journal:  Methods Mol Biol       Date:  2023

7.  Parallel Detection of Fundamental and Sixth Harmonic Signals Using an ICR Cell with Dipole and Sixth Harmonic Detectors.

Authors:  Sung-Gun Park; Gordon A Anderson; James E Bruce
Journal:  J Am Soc Mass Spectrom       Date:  2020-01-30       Impact factor: 3.109

Review 8.  Applications and advancements of FT-ICR-MS for interactome studies.

Authors:  Juan D Chavez; Sung-Gun Park; Jared P Mohr; James E Bruce
Journal:  Mass Spectrom Rev       Date:  2020-12-08       Impact factor: 10.946

9.  Application of frequency multiple FT-ICR-MS signal acquisition for improved proteome research.

Authors:  Sung-Gun Park; Jared P Mohr; Gordon A Anderson; James E Bruce
Journal:  Int J Mass Spectrom       Date:  2021-03-19       Impact factor: 1.934

10.  A Comparative Study of Pyrolysis Liquids by Slow Pyrolysis of Industrial Hemp Leaves, Hurds and Roots.

Authors:  Ayobami Salami; Jorma Heikkinen; Laura Tomppo; Marko Hyttinen; Timo Kekäläinen; Janne Jänis; Jouko Vepsäläinen; Reijo Lappalainen
Journal:  Molecules       Date:  2021-05-25       Impact factor: 4.411

View more