Literature DB >> 15383967

Ex-vivo injection technique for implanting solid pulmonary nodules into porcine lungs for multi-slice CT.

H Bolte1, S Müller-Hülsbeck, C Riedel, T Jahnke, N Inan, M Heller, J Biederer.   

Abstract

PURPOSE: To develop a method for generating realistic pulmonary nodules that equal small pulmonary metastases and granulomas.
MATERIALS AND METHODS: A total of 70 artificial lesions were introduced into 5 inflated porcine lungs inside a dedicated chest phantom by high pressure injection of a fat-wax-Lipiodol mixture and scanned with 16-slice computed tomography (CT). Image evaluation by two experienced radiologists included analysis of morphology, nodule size and density.
RESULTS: The median nodule density was 78.8 Hounsfield units (HU), with 54 of 70 nodules (77.14 %) judged typical of small lung metastases.
CONCLUSION: Without inducing visible damage of lung parenchyma, the injection technique produces highly realistic pulmonary nodules for morphometry or nodule detection with CT.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15383967     DOI: 10.1055/s-2004-813558

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  5 in total

1.  Insertion of virtual pulmonary nodules in CT data of the chest: development of a software tool.

Authors:  Hoen-oh Shin; Matthias Blietz; Bernd Frericks; Stefan Baus; Dagmar Savellano; Michael Galanski
Journal:  Eur Radiol       Date:  2006-07-04       Impact factor: 5.315

2.  Pulmonary nodule detection with digital projection radiography: an ex-vivo study on increased latitude post-processing.

Authors:  Juergen Biederer; Tobias Gottwald; Hendrik Bolte; Christian Riedel; Sandra Freitag; Richard Van Metter; Martin Heller
Journal:  Eur Radiol       Date:  2006-09-09       Impact factor: 5.315

3.  Detection of small pulmonary nodules in high-field MR at 3 T: evaluation of different pulse sequences using porcine lung explants.

Authors:  M Regier; S Kandel; M G Kaul; B Hoffmann; H Ittrich; P M Bansmann; J Kemper; C Nolte-Ernsting; M Heller; G Adam; J Biederer
Journal:  Eur Radiol       Date:  2006-09-30       Impact factor: 5.315

4.  Evaluation of motion measurement using cine MRI for image guided stereotactic body radiotherapy on a new phantom platform.

Authors:  Zheng Chang; Jing Cai; Ziheng Wang; Fang-Fang Yin
Journal:  J Radiosurg SBRT       Date:  2011

5.  MDCT assessment of airway wall thickness in COPD patients using a new method: correlations with pulmonary function tests.

Authors:  Tobias Achenbach; Oliver Weinheimer; Alexander Biedermann; Sabine Schmitt; Daniela Freudenstein; Edula Goutham; Richard Peter Kunz; Roland Buhl; Christoph Dueber; Claus Peter Heussel
Journal:  Eur Radiol       Date:  2008-07-19       Impact factor: 5.315

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.