Literature DB >> 29286458

Surgical Training for the Implantation of Neocortical Microelectrode Arrays Using a Formaldehyde-fixed Human Cadaver Model.

Pierre Mégevand1, Alain Woodtli2, Aude Yulzari2, G Rees Cosgrove3, Shahan Momjian4, Bojan V Stimec5, Marco V Corniola4, Jean H D Fasel5.   

Abstract

This protocol describes a procedure to assist surgeons in training for the implantation of microelectrode arrays into the neocortex of the human brain. Recent technological progress has enabled the fabrication of microelectrode arrays that allow recording the activity of multiple individual neurons in the neocortex of the human brain. These arrays have the potential to bring unique insight onto the neuronal correlates of cerebral function in health and disease. Furthermore, the identification and decoding of volitional neuronal activity opens the possibility to establish brain-computer interfaces, and thus might help restore lost neurological functions. The implantation of neocortical microelectrode arrays is an invasive procedure requiring a supra-centimetric craniotomy and the exposure of the cortical surface; thus, the procedure must be performed by an adequately trained neurosurgeon. In order to provide an opportunity for surgical training, we designed a procedure based on a human cadaver model. The use of a formaldehyde-fixed human cadaver bypasses the practical, ethical and financial difficulties of surgical practice on animals (especially non-human primates) while preserving the macroscopic structure of the head, skull, meninges and cerebral surface and allowing realistic, operating room-like positioning and instrumentation. Furthermore, the use of a human cadaver is closer to clinical daily practice than any non-human model. The major drawbacks of the cadaveric simulation are the absence of cerebral pulsation and of blood and cerebrospinal fluid circulation. We suggest that a formaldehyde-fixed human cadaver model is an adequate, practical and cost-effective approach to ensure proper surgical training before implanting microelectrode arrays in the living human neocortex.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 29286458      PMCID: PMC5755428          DOI: 10.3791/56584

Source DB:  PubMed          Journal:  J Vis Exp        ISSN: 1940-087X            Impact factor:   1.355


  43 in total

1.  Endoscopic endonasal transsphenoidal exposure of circle of Willis (CW); can it be applied in vascular neurosurgery in the near future? A cadaveric study of 26 cases.

Authors:  Forhad H Chowdhury; Mohammod R Haque; Khandkar A Kawsar; Shamim Ara; Quazi Deen Mohammod; Mainul H Sarker; Atul H Goel
Journal:  Turk Neurosurg       Date:  2012       Impact factor: 1.003

2.  Microsurgical anatomic features of the olfactory nerve: relevance to olfaction preservation in the pterional approach.

Authors:  Salvatore Cardali; Alberto Romano; Filippo Flavio Angileri; Alfredo Conti; Domenico La Torre; Oreste de Divitiis; Domenico d'Avella; Manfred Tschabitscher; Francesco Tomasello
Journal:  Neurosurgery       Date:  2005-07       Impact factor: 4.654

3.  Using 3D Printing to Create Personalized Brain Models for Neurosurgical Training and Preoperative Planning.

Authors:  Caitlin C Ploch; Chris S S A Mansi; Jayaratnam Jayamohan; Ellen Kuhl
Journal:  World Neurosurg       Date:  2016-02-24       Impact factor: 2.104

Review 4.  Adverse events related to extraoperative invasive EEG monitoring with subdural grid electrodes: a systematic review and meta-analysis.

Authors:  Ravindra Arya; Francesco T Mangano; Paul S Horn; Katherine D Holland; Douglas F Rose; Tracy A Glauser
Journal:  Epilepsia       Date:  2013-01-07       Impact factor: 5.864

5.  Human cadaver brain infusion model for neurosurgical training.

Authors:  Jon Olabe; Javier Olabe; Vidal Sancho
Journal:  Surg Neurol       Date:  2009-08-06

6.  Instant neural control of a movement signal.

Authors:  Mijail D Serruya; Nicholas G Hatsopoulos; Liam Paninski; Matthew R Fellows; John P Donoghue
Journal:  Nature       Date:  2002-03-14       Impact factor: 49.962

7.  A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array.

Authors:  P K Campbell; K E Jones; R J Huber; K W Horch; R A Normann
Journal:  IEEE Trans Biomed Eng       Date:  1991-08       Impact factor: 4.538

8.  The human K-complex represents an isolated cortical down-state.

Authors:  Sydney S Cash; Eric Halgren; Nima Dehghani; Andrea O Rossetti; Thomas Thesen; Chunmao Wang; Orrin Devinsky; Ruben Kuzniecky; Werner Doyle; Joseph R Madsen; Edward Bromfield; Loránd Eross; Péter Halász; George Karmos; Richárd Csercsa; Lucia Wittner; István Ulbert
Journal:  Science       Date:  2009-05-22       Impact factor: 47.728

9.  Massively parallel recording of unit and local field potentials with silicon-based electrodes.

Authors:  Jozsef Csicsvari; Darrell A Henze; Brian Jamieson; Kenneth D Harris; Anton Sirota; Péter Barthó; Kensall D Wise; György Buzsáki
Journal:  J Neurophysiol       Date:  2003-08       Impact factor: 2.714

10.  Cadaveric Spinal Surgery Simulation: A Comparison of Cadaver Types.

Authors:  James E Tomlinson; Marina Yiasemidou; Anna L Watts; Dave J H Roberts; Jake Timothy
Journal:  Global Spine J       Date:  2015-09-29
View more
  1 in total

1.  Meningeal inflammatory response and fibrous tissue remodeling around intracortical implants: An in vivo two-photon imaging study.

Authors:  J R Eles; A L Vazquez; T D Y Kozai; X T Cui
Journal:  Biomaterials       Date:  2018-12-31       Impact factor: 12.479

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.