Literature DB >> 29283934

Raw and Count Data Comparability of Hip-Worn ActiGraph GT3X+ and Link Accelerometers.

Alexander H K Montoye1,1, M Benjamin Nelson1, Joshua M Bock1, Mary T Imboden1, Leonard A Kaminsky1, Kelly A Mackintosh1, Melitta A McNarry1, Karin A Pfeiffer1.   

Abstract

To enable inter- and intrastudy comparisons it is important to ascertain comparability among accelerometer models.
PURPOSE: The purpose of this study was to compare raw and count data between hip-worn ActiGraph GT3X+ and GT9X Link accelerometers.
METHODS: Adults (n = 26 (n = 15 women); age, 49.1 ± 20.0 yr) wore GT3X+ and Link accelerometers over the right hip for an 80-min protocol involving 12-21 sedentary, household, and ambulatory/exercise activities lasting 2-15 min each. For each accelerometer, mean and variance of the raw (60 Hz) data for each axis and vector magnitude (VM) were extracted in 30-s epochs. A machine learning model (Montoye 2015) was used to predict energy expenditure in METs from the raw data. Raw data were also processed into activity counts in 30-s epochs for each axis and VM, with Freedson 1998 and 2011 count-based regression models used to predict METs. Time spent in sedentary, light, moderate, and vigorous intensities was derived from predicted METs from each model. Correlations were calculated to compare raw and count data between accelerometers, and percent agreement was used to compare epoch-by-epoch activity intensity.
RESULTS: For raw data, correlations for mean acceleration were 0.96 ± 0.05, 0.89 ± 0.16, 0.71 ± 0.33, and 0.80 ± 0.28, and those for variance were 0.98 ± 0.02, 0.98 ± 0.03, 0.91 ± 0.06, and 1.00 ± 0.00 in the X, Y, and Z axes and VM, respectively. For count data, corresponding correlations were 1.00 ± 0.01, 0.98 ± 0.02, 0.96 ± 0.04, and 1.00 ± 0.00, respectively. Freedson 1998 and 2011 count-based models had significantly higher percent agreement for activity intensity (95.1% ± 5.6% and 95.5% ± 4.0%) compared with the Montoye 2015 raw data model (61.5% ± 27.6%; P < 0.001).
CONCLUSIONS: Count data were more highly comparable than raw data between accelerometers. Data filtering and/or more robust raw data models are needed to improve raw data comparability between ActiGraph GT3X+ and Link accelerometers.

Entities:  

Mesh:

Year:  2018        PMID: 29283934     DOI: 10.1249/MSS.0000000000001534

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  9 in total

1.  Ordinal Statistical Models of Physical Activity Levels from Accelerometer Data.

Authors:  Shafayet S Hossain; Drew M Lazar; Munni Begum
Journal:  Int J Exerc Sci       Date:  2021-04-01

2.  Assessment of Free-Living Cadence Using ActiGraph Accelerometers Between Individuals With and Without Anterior Cruciate Ligament Reconstruction.

Authors:  Caroline M Lisee; Alexander H K Montoye; Noble F Lewallen; Mayrena Hernandez; David R Bell; Christopher M Kuenze
Journal:  J Athl Train       Date:  2020-09-01       Impact factor: 2.860

3.  Integrating smartphone technology, social support and the outdoor built environment to promote community-based aerobic and resistance-based physical activity: Rationale and study protocol for the 'ecofit' randomized controlled trial.

Authors:  Anna K Jansson; David R Lubans; Jordan J Smith; Mitch J Duncan; Adrian Bauman; John Attia; Sara L Robards; Ronald C Plotnikoff
Journal:  Contemp Clin Trials Commun       Date:  2019-09-24

4.  A novel algorithm to detect non-wear time from raw accelerometer data using deep convolutional neural networks.

Authors:  Shaheen Syed; Bente Morseth; Laila A Hopstock; Alexander Horsch
Journal:  Sci Rep       Date:  2021-04-23       Impact factor: 4.379

5.  Adolescents Are Less Physically Active Than Adults After Anterior Cruciate Ligament Reconstruction.

Authors:  Christopher Kuenze; Katherine Collins; Ashley Triplett; David Bell; Grant Norte; Shelby Baez; Matthew Harkey; Luke Wilcox; Caroline Lisee
Journal:  Orthop J Sports Med       Date:  2022-02-21

6.  Comparison of Polar Active Watch and Waist- and Wrist-Worn ActiGraph Accelerometers for Measuring Children's Physical Activity Levels during Unstructured Afterschool Programs.

Authors:  Youngdeok Kim; Marc Lochbaum
Journal:  Int J Environ Res Public Health       Date:  2018-10-16       Impact factor: 3.390

7.  Application and Validation of Activity Monitors' Epoch Lengths and Placement Sites for Physical Activity Assessment in Exergaming.

Authors:  Jungyun Hwang; Austin Michael Fernandez; Amy Shirong Lu
Journal:  J Clin Med       Date:  2018-09-11       Impact factor: 4.241

8.  Evaluating the performance of raw and epoch non-wear algorithms using multiple accelerometers and electrocardiogram recordings.

Authors:  Shaheen Syed; Bente Morseth; Laila A Hopstock; Alexander Horsch
Journal:  Sci Rep       Date:  2020-04-03       Impact factor: 4.379

9.  Development and Evaluation of an Accelerometer-Based Protocol for Measuring Physical Activity Levels in Cancer Survivors: Development and Usability Study.

Authors:  Tracy E Crane; Meghan B Skiba; Austin Miller; David O Garcia; Cynthia A Thomson
Journal:  JMIR Mhealth Uhealth       Date:  2020-09-24       Impact factor: 4.773

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.