Literature DB >> 29278709

Real-world flash glucose monitoring patterns and associations between self-monitoring frequency and glycaemic measures: A European analysis of over 60 million glucose tests.

Timothy C Dunn1, Yongjin Xu2, Gary Hayter3, Ramzi A Ajjan4.   

Abstract

AIMS: Randomised controlled trials demonstrate that using flash glucose monitoring improves glycaemic control but it is unclear whether this applies outside trial conditions. We investigated glucose testing patterns in users worldwide under real life settings to establish testing frequency and association with glycaemic parameters.
METHODS: Glucose results were de-identified and uploaded onto a dedicated database once readers were connected to an internet-ready computer. Data between September 2014 and May 2016, comprising 50,831 readers and 279,446 sensors worldwide, were analysed. Scan rate per reader was determined and each reader was sorted into twenty equally-sized rank-ordered groups, categorised by scan frequency. Glucose parameters were calculated for each group, including estimated HbA1c, time above, below and within range identified as 3.9-10.0 mmol/L.
RESULTS: Users performed a mean of 16.3 scans/day [median (IQR): 14 (10-20)] with 86.4 million hours of readings and 63.8 million scans. Estimated HbA1c gradually reduced from 8.0% to 6.7% (64 to 50 mmol/mol) as scan rate increased from lowest to highest scan groups (4.4 and 48.1 scans/day, respectively; p < .001). Simultaneously, time below 3.9, 3.1 and 2.5 mmol/L decreased by 15%, 40% and 49%, respectively (all p < .001). Time above 10.0 mmol/L decreased from 10.4 to 5.7 h/day (44%, p < .001) while time in range increased from 12.0 to 16.8 h/day (40%, p < .001). These patterns were consistent across different countries.
CONCLUSIONS: In real-world conditions, flash glucose monitoring allows frequent glucose checks with higher rates of scanning linked to improved glycaemic markers, including increased time in range and reduced time in hyper and hypoglycaemia.
Copyright © 2017 Abbott Diabetes Care. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Blood glucose monitoring frequency; Flash glucose monitoring; Glycaemic measures; Real-world data

Mesh:

Substances:

Year:  2017        PMID: 29278709     DOI: 10.1016/j.diabres.2017.12.015

Source DB:  PubMed          Journal:  Diabetes Res Clin Pract        ISSN: 0168-8227            Impact factor:   5.602


  57 in total

1.  Distribution of Highly Prevalent Musculoskeletal Disorders and Their Association With Diabetes Complications in a Population of 140 Individuals With Type 1 Diabetes: A Retrospective Study in a French Diabetes Center.

Authors:  Sylvie Picard; Dimitar Vasilevski; Guy Fagherazzi
Journal:  Clin Diabetes       Date:  2020-04

2.  Text Message Intervention for Teens with Type 1 Diabetes Preserves HbA1c: Results of a Randomized Controlled Trial.

Authors:  Dayna E McGill; Lori M Laffel; Lisa K Volkening; Deborah A Butler; Wendy L Levy; Rachel M Wasserman; Barbara J Anderson
Journal:  Diabetes Technol Ther       Date:  2020-05       Impact factor: 6.118

3.  Real-World Hypoglycemia Avoidance With a Predictive Low Glucose Alert Does Not Depend on Frequent Screen Views.

Authors:  Sarah Puhr; Mark Derdzinski; Andrew Scott Parker; John B Welsh; David A Price
Journal:  J Diabetes Sci Technol       Date:  2019-04-03

Review 4.  Health Technology Assessments for Flash Glucose Monitoring and How to Use Them in Everyday Clinical Practice.

Authors:  Magnus Stueve; Oliver Schnell
Journal:  J Diabetes Sci Technol       Date:  2018-08-22

5.  Flash glucose monitoring and glycemic control in type 1 diabetes with subcutaneous insulin infusion.

Authors:  Sara Lomelino Pinheiro; Margarida Bastos; Luísa Barros; Miguel Melo; Isabel Paiva
Journal:  Acta Diabetol       Date:  2021-11-16       Impact factor: 4.280

6.  Flash Continuous Glucose Monitoring: Implications for Use of Continuous Data in Daily Diabetes Management.

Authors:  Irl B Hirsch; Elizabeth Nardacci; Carol A Verderese
Journal:  Diabetes Spectr       Date:  2019-11

7.  Initial experiences of adolescents and young adults with type 1 diabetes and high-risk glycemic control after starting flash glucose monitoring - a qualitative study.

Authors:  Sara Boucher; Miranda Blackwell; Barbara Galland; Martin de Bock; Hamish Crocket; Esko Wiltshire; Paul Tomlinson; Jenny Rayns; Benjamin Wheeler
Journal:  J Diabetes Metab Disord       Date:  2019-12-07

8.  Glycemic Metrics Derived From Intermittently Scanned Continuous Glucose Monitoring.

Authors:  Klavs Würgler Hansen; Bo Martin Bibby
Journal:  J Diabetes Sci Technol       Date:  2020-12-03

9.  Effect of flash glucose monitoring in adults with type 1 diabetes: a nationwide, longitudinal observational study of 14,372 flash users compared with 7691 glucose sensor naive controls.

Authors:  David Nathanson; Ann-Marie Svensson; Mervete Miftaraj; Stefan Franzén; Jan Bolinder; Katarina Eeg-Olofsson
Journal:  Diabetologia       Date:  2021-03-27       Impact factor: 10.122

10.  Frequency of Diabetic Ketoacidosis in Patients with Type 1 Diabetes Using FreeStyle Libre: A Retrospective Chart Review.

Authors:  Ayman A Al Hayek; Mohamed A Al Dawish
Journal:  Adv Ther       Date:  2021-05-19       Impact factor: 3.845

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.