Small-angle X-ray scattering tensor tomography, which allows reconstruction of the local three-dimensional reciprocal-space map within a three-dimensional sample as introduced by Liebi et al. [Nature (2015), 527, 349-352], is described in more detail with regard to the mathematical framework and the optimization algorithm. For the case of trabecular bone samples from vertebrae it is shown that the model of the three-dimensional reciprocal-space map using spherical harmonics can adequately describe the measured data. The method enables the determination of nanostructure orientation and degree of orientation as demonstrated previously in a single momentum transfer q range. This article presents a reconstruction of the complete reciprocal-space map for the case of bone over extended ranges of q. In addition, it is shown that uniform angular sampling and advanced regularization strategies help to reduce the amount of data required.
Small-angle X-ray scattering tensor tomography, which allows reconstruction of the local three-dimensional reciprocal-space map within a three-dimensional sample as introduced by Liebi et al. [Nature (2015), 527, 349-352], is described in more detail with regard to the mathematical framework and the optimization algorithm. For the case of trabecular bone samples from vertebrae it is shown that the model of the three-dimensional reciprocal-space map using spherical harmonics can adequately describe the measured data. The method enables the determination of nanostructure orientation and degree of orientation as demonstrated previously in a single momentum transfer q range. This article presents a reconstruction of the complete reciprocal-space map for the case of bone over extended ranges of q. In addition, it is shown that uniform angular sampling and advanced regularization strategies help to reduce the amount of data required.
Nanoscale features can be probed in a spatially resolved fashion when scanning a sample through a focused X-ray beam and recording a small-angle X-ray scattering (SAXS) pattern at each location (Fratzl et al., 1997 ▸), a technique referred to as scanning SAXS. The real-space resolution is defined by the beam size and the scanning step size, which is typically chosen in the order of several to a few tens of micrometres, but can also be as small as some tens of nanometres or as large as millimetres. For each scanning point, nanoscale features are probed in reciprocal space by the SAXS pattern, typically measuring a spectrum of feature sizes in the range of a few nanometres to a few hundred nanometres. The capability to study the distribution of nanoscale structures over extended sample areas is of particular interest for hierarchically structured materials for which the length scales of interest span many orders of magnitude (Fratzl & Weinkamer, 2007 ▸; Meyers et al., 2008 ▸; Beniash, 2011 ▸; He et al., 2015 ▸; Van Opdenbosch et al., 2016 ▸).A two-dimensional SAXS pattern contains statistical information about the nanostructure within the illuminated sample volume. If a main direction of orientation of the nanostructure exists, it can be determined in a model-independent way. Since a single SAXS pattern probes only a two-dimensional section through the three-dimensional reciprocal space, it provides incomplete information if the nanostructure is anisotropic in three dimensions. The three-dimensional orientation can be retrieved from thin sections of a sample by measuring SAXS patterns at different rotation angles, as illustrated in Fig. 1 ▸(a) (Liu et al., 2010 ▸; Seidel et al., 2012 ▸; Georgiadis et al., 2015 ▸). To measure three-dimensional samples without sectioning, scanning SAXS has to be combined with computed tomography (CT) techniques. If the scattering is invariant with respect to sample rotation (Feldkamp et al., 2009 ▸), measurements taken at different angles for one rotation axis are enough and a standard reconstruction algorithm, such as filtered back-projection or simultaneous algebraic reconstruction technique (SART), can be used. Rotational invariance applies for isotropically scattering samples, i.e. with no preferred orientation of the nanostructure or for unidirectional orientation of the nanostructure parallel to the rotation axis (Schroer et al., 2006 ▸; Feldkamp et al., 2009 ▸; Jensen et al., 2011 ▸).
Figure 1
(a) Three-dimensional scanning SAXS setup to measure thinly sliced samples. The sample is scanned through the focused beam in x and y at different rotation angles β around y. (b) SAXS tensor tomography setup to measure three-dimensional samples. The sample is scanned through the focused beam in x and y at n orientations which are described by the rotation matrix .
Skjønsfjell et al. (2016 ▸) have shown that, with strict assumptions on the sample, the orientation distribution can be retrieved from measurements using a single rotation axis by fitting a model of the X-ray scattering to the experimental SAXS pattern. For more general anisotropically oriented scatterers, SAXS acquisition using two rotation axes is needed (see Fig. 1 ▸
b) in order to retrieve the full three-dimensional reciprocal-space map (Liebi et al., 2015 ▸; Schaff et al., 2015 ▸). Schaff et al. (2015 ▸) have extended the concept of the rotation invariance (Feldkamp et al., 2009 ▸) by the introduction of virtual tomographic axes. After sorting the two-dimensional SAXS patterns acquired at different rotations around two axes into over a thousand virtual tomography axes, standard reconstruction algorithms, here SART, are used to reconstruct the scattering parallel to each virtual tomographic axis independently.Liebi et al. (2015 ▸) introduced a method based on the modelling of the three-dimensional reciprocal-space map of each voxel, i.e. volume element, using spherical harmonics and minimizing the error between the measured and modelled intensity by an optimization algorithm. The reconstruction contains in each voxel not only a scalar value, such as the X-ray attenuation coefficient in standard CT, but a tensor representing the reciprocal-space map; thus the method is referred to as SAXS tensor tomography. We present here in more detail the mathematical framework of SAXS tensor tomography, as introduced by Liebi et al. (2015 ▸), and the experimental validation of the model demonstrated on trabecular bone samples. We further investigate the angular sampling and the number of projections required for the reconstruction. In addition, some advanced regularization strategies are introduced and discussed, which reduce the amount of data and measurement time needed.
Model of the scattering signal using a three-dimensional reciprocal-space map
The ab initio characterization of the anisotropy of nanostrucure in a three-dimensional volume requires measurement of the sample from many possible orientations, not only around one rotation axis, but in a grid of two-dimensional orientation angles using two rotation axes. It is necessary to define a coordinate transformation from laboratory coordinates , with z pointing along the direction of the X-ray beam, to sample Cartesian coordinates , as illustrated in Fig. 2 ▸. This transformation is described for the nth sample orientation by a rotation matrix .
Figure 2
(a) Laboratory coordinate system and (b) object-coordinate system , which are related by the rotation matrix . In (a) the planar two-dimensional cut through the reciprocal-space map in the plane of the detector is illustrated in grey. The object-coordinate system defines the position of each voxel of the object. (c) In each voxel a series of spherical harmonics functions is used to describe the three-dimensional reciprocal-space map, from which the scattering signal can be obtained. The preferential orientation of the nanostructure in each voxel and each q is characterized by a unit vector defined by the polar and azimuthal angles.
The reconstruction aims to determine for each object-coordinate voxel, , a three-dimensional reciprocal-space map, , as a function of a reciprocal-space vector . The object-coordinate system can also be described in spherical coordinates , with being the polar angle and the azimuthal angle. In order to reach this objective, the reciprocal-space map is modelled using spherical harmonics of degree l and order m (Jackson, 1999 ▸) as where is the magnitude of the reciprocal-space vector, are the spherical harmonic coefficients, and and are the polar and azimuthal angles, respectively, which are arguments of the spherical harmonic function. The square of the sum is used to avoid non-physical negative intensities. Since spherical harmonics form a complete basis, higher orders can be used to model the scattering of arbitrarily complex nanostructures. For example, spherical harmonics were used in texture analysis of pole figures from X-ray diffraction measurements decades ago (Roe & Krigbaum, 1964 ▸; Bunge & Roberts, 1969 ▸) using orders up to (Van Houtte, 1983 ▸). When reconstructing a scattering model for a large number of voxels of an extended sample however, reducing the number of coefficients and thus minimizing the total number of optimization parameters is of great benefit. For cases where there is a preferential direction of ordering for the nanostructure it is useful to orient the zenith of the spherical harmonics to this direction independently for each voxel in each q range. This results in a sparser representation and reduces the number of coefficients needed to model the reciprocal-space map. This is a particularly good strategy in cases where the three-dimensional reciprocal-space map is not too far from spherical or ellipsoidal symmetry; thus only a few components are required in the decomposition of in equation (1). The local preferential orientation with respect to the object coordinates is characterized by a unit vector, (), as illustrated in Fig. 2 ▸(c), which is parameterized by the angles and . The arguments of the spherical harmonics, and , can be implicitly defined by where are the spherical coordinates of the object-coordinate system. Neglecting multiple-scattering effects, the contribution of each voxel to the intensity measured at the detector corresponds to a section through the three-dimensional reciprocal space along the Ewald sphere of radius . For the case of SAXS an expansion of zero order of the Ewald sphere leads to a planar two-dimensional cut through the reciprocal-space map, i.e.
, in the laboratory coordinate Cartesian system as illustrated in Fig. 2 ▸(a). The data in the plane correspond to the plane or in spherical coordinates. In order to calculate the total intensity at the detector for the nth sample orientation, the contribution from all voxels along the beam path z is summed up, where the measured intensity for the nth sample orientation, , is a function of the scanning position .
Optimization algorithm
For the reconstruction of the three-dimensional reciprocal-space map in one specific q range, an iterative optimization algorithm is used to minimize the error metric between the modelled intensity, as calculated in equation (3), with respect to the measured data , for all scanning positions and sample orientations, Minimizing this error metric is a first-order approximation to a maximum-likelihood estimation for photon-counting Poisson noise (Thibault & Guizar-Sicairos, 2012 ▸). The measured intensity at each point and each orientation is divided by the transmitted intensity to compensate for absorption of the sample (Schroer et al., 2006 ▸). The parameters to optimize are the spherical harmonic coefficients, , and their orientation through and . A binary mask, , is used to denote valid data regions. It is equal to one for all valid data points and can be set to zero for bad detector angular sectors, φ, or where the scattering of the sample is obstructed, for example by the sample mount.To compute we first evaluate the sum of the different spherical harmonic terms and compute the modulus squared. The resulting quantity is then projected along the direction of the X-ray beam. The projection operation is calculated using bilinear interpolation. The resulting image is convolved with a pyramidal kernel, which emulates the effect of up- and subsequent down-sampling, to reduce artifacts associated with the discrete volume grid. For the minimization of the error metric, given in equation (4), a conjugate gradient algorithm was used (Press et al., 2007 ▸). As the number of optimization parameters is very large, the gradient of the error metric with respect to the optimization parameters is calculated analytically (see Appendix A
). In each iteration step the gradient is computed according to equations (10), (11) and (14), followed by a line search in a conjugate direction induced by the local curvature of the function to be optimized [equation (4)].In order to accelerate convergence, the optimization is performed in four steps as illustrated in Fig. 3 ▸. First, the isotropic component of the reciprocal-space map is optimized by using only the isotropic spherical harmonic term with and and averaging the data over φ. Secondly, only the angles are optimized and the coefficients for , are kept constant at a factor s times the obtained in the first step. For the bone measurements shown in this paper the coefficients were set to for , for and for . These coefficients were chosen to approximate the anisotropy which was observed in similar samples. Alternatively, symmetries in the three-dimensional reciprocal-space map, which help in determining the number of spherical harmonics functions needed, can be estimated from the shape of the scattering object studied. Without previous knowledge of the sample, by repeating the optimization procedure with different constant values of the coefficients in the second step and comparing the results, one can avoid a solution being obtained which is just a local minimum of the error metric. It is also possible to gain knowledge about the three-dimensional reciprocal-space map by studying a flat sample at different sample rotations as outlined in §4. In the third step the coefficients , and were optimized while the angles and from the first step were kept constant. Finally, in the last step all coefficients and angles were optimized simultaneously.
Figure 3
Flowchart of the optimization procedure. The output of the optimization is for each object-coordinate voxel the three-dimensional reciprocal-space map parameterized by the preferential orientation and the coefficients of the spherical harmonics . The optimization is performed in four steps to accelerate convergence. Red dotted lines indicate starting values of the modelled intensity in each step, whereas solid red lines indicate the resulting after the corresponding optimization step. The measured intensity is shown as black dots; in the first step the optimization is performed using the data averaged over φ.
A support constraint on the object was used in order to optimize only the part of the object three-dimensional grid volume which contains the sample. For this a three-dimensional binary support mask, , is introduced, denoting with zeros the regions without sample. This can be obtained, for example, using a threshold after the first optimization step where a first estimate of is obtained. The mask, , is then used when computing the gradients to set the gradients outside the object to zero, as shown in equations (10), (11) and (14). Boundary conditions on the values of the coefficients can be introduced either using constrained optimization algorithms or by introducing a smooth penalty term to the error metric. This can be used for example to enforce symmetries if it is known that they are present in the sample. For example, for the case of
where Here λ controls the strength of the penalty term. In the reconstructions shown in the article, no such penalty term was used. The regularization term, , in equation (5) will be explained in §5.2.
Experimental validation of the reciprocal-space model for trabecular bone
To validate the suitability of a series of spherical harmonics as a model to describe the three-dimensional reciprocal-space map, we used data from a 20 µm-thin section of trabecular bone (sample A). The data were taken with a beam size of 20 × 20 µm at different rotation angles β around the y axis of the beamline coordinate system as illustrated in Fig. 1 ▸(a). Further experimental details can be found in Appendix B
. As the lateral resolution matches the thickness, the measurements give an adequate representation of imaging a planar arrangement of voxels and it has been shown that for thin samples a single rotation axis provides sufficient information on the three-dimensional arrangement of nanostructures (Georgiadis et al., 2015 ▸). Image registration (Guizar-Sicairos et al., 2008 ▸) of the transmission images, recorded simultaneously to the SAXS data, was used to assign the scattering from multiple orientations to individual voxels. This procedure is described in more detail by Georgiadis et al. (2015 ▸).Fig. 4 ▸ shows a single scattering pattern from one scan point of the measurement. Since the nanostructure causing the scattering has a preferential orientation, the recorded SAXS pattern is anisotropic. Furthermore, since the nanostructure anisotropy is three dimensional, the scattering pattern depends on the sample orientation, β (Georgiadis et al., 2015 ▸). The scattering from bone originates mainly from the electron-density contrast between hydroxyapatite mineral crystal platelets and the surrounding material with lower electron density, such as collagen and water (Fratzl et al., 1997 ▸). The main characteristics of the two-dimensional SAXS signal from bone are the distinct Bragg reflections from the periodic gaps in the collagen fibrils which are filled by hydroxyapatite crystals (Fratzl et al., 1991 ▸). The repeat distance of these gaps is approximately 65 nm and they produce characteristic arcs in the scattering pattern (Wilkinson & Hukins, 1999 ▸). The first and third harmonic of this signal are indicated by white triangles in Fig. 4 ▸. In the direction perpendicular to these arcs a fan-shaped scattering profile can be seen, which arises from the shape, size and lateral arrangement of the mineral platelets in and around the collagen fibrils (Norio et al., 1982 ▸). At high q values, q > 0.125 nm−1, primarily the mineral platelets with an approximate size of 3 × 25 × 50 nm can be probed. At low q values, q < 0.1 nm−1, the scattering contains mainly information on the lateral arrangement of the collagen fibrils and the diameter of the fibrils, which is typically in the range of 50–200 nm (Fratzl & Weinkamer, 2007 ▸; Gourrier et al., 2010 ▸; Pabisch et al., 2013 ▸; Giannini et al., 2014 ▸). The organization of bone is hierarchical: the orientation of the mineral crystals, the collagen fibrils, the fibril bundles, the fibres and the macroscopic bone organization are closely related to each other (Rinnerthaler et al., 1999 ▸; Fratzl & Weinkamer, 2007 ▸; Seidel et al., 2012 ▸; Granke et al., 2013 ▸; Georgiadis et al., 2015 ▸, 2016 ▸).
Figure 4
Two-dimensional scattering pattern in logarithmic scale obtained from a thin slice of trabecular bone and a zoom-in to the low-q range. The 16 segments in which the radial integration is performed are indicated by white lines and two circles that mark a range of q values. White triangles point at the pronounced first and the faint third diffraction orders of mineralized collagen fibres.
The intensity of each scattering pattern was integrated in 16 azimuthal segments, shown by white lines in Fig. 4 ▸, for each momentum transfer q. Increasing the number of azimuthal segments was found to have no significant influence on the results while increasing the amount of data and calculation time. Black dots in Fig. 5 ▸ show the measured intensity at the detector versus azimuthal angle φ in one q range, 0.0379–0.0758 nm−1, indicated by concentric circles in Fig. 4 ▸ in the 16 azimuthal segments. Symmetries, such as point symmetry, are very common in SAXS and can be easily enforced in our model by choosing the appropriate degrees and orders of the spherical harmonics. For the case of trabecular bone we assume a point symmetry around and a rotational symmetry around one axis. Thus, using only even degree l and zero order m is enough to model the scattering signal retrieved from the three-dimensional reciprocal-space map. If the mineral platelets did not point in all directions perpendicular to the fibril axis with equal probability, the resulting reciprocal-space map would not be a ring with cylindrical rotational symmetry. For this case in which the rotational symmetry is not given, higher azimuthal orders, m, of spherical harmonics are needed to capture this feature. Fig. 5 ▸ shows for one sample orientation, β = 20°, the intensity at the detector versus azimuthal angle φ, for the measured and modelled data. The azimuthal orientation of the scattering pattern can already be described well using only degrees . However the only functional dependence allowed for these small orders is a sine or cosine function (blue line in Fig. 5 ▸), which is insufficient to quantitatively model the scattering profile, as can be seen in Fig. 5 ▸. Using and (red line) the sharpness of the peak is not yet described fully, and an artificial increase in the low-intensity region appears. Using spherical harmonics of degree and order (green line) it is possible to reproduce reliably the measured data. Adding yet a higher degree (yellow line) does not improve the model significantly.
Figure 5
SAXS measurements from a single voxel for q = (0.0379–0.0758 nm−1) for one sample rotation angle β = 20° are shown with black dots. The corresponding modelled data (lines) with different degrees l and zero order m of spherical harmonics are shown as a function of the azimuthal angle φ in the detector plane.
Consequently, the model was applied with and to reconstruct the q-resolved three-dimensional reciprocal-space map from the data set from sample A. The optimization was performed at 32 q values between 0.0303 and 0.984 nm−1, each with a radial width of 0.0061 nm−1. Fig. 6 ▸ shows a good agreement of the fit (points and dashed lines) with the data (solid lines) for the full q range covered by the two-dimensional detector. For selected q values the modelled three-dimensional reciprocal-space map is shown. The characteristic reciprocal-space footprint of the mineral platelets, which appears as a fan-shaped profile in a two-dimensional pattern as seen in Fig. 4 ▸, appears in the three-dimensional reciprocal-space map as a ring perpendicular to the direction of the fibril axis and with angular spread related to the fibrils’ degree of orientation. This ring can be observed in the whole investigated q range in Fig. 6 ▸. The Bragg reflection, which is associated with the collagen periodic gaps, appears in the three-dimensional reciprocal-space map as a cap. It is visible for the first and third harmonic of the reflection (see triangle in Fig. 6 ▸). Using and is enough to capture both features typical for the scattering from bone. Reconstructing the full q-resolved three-dimensional reciprocal-space map opens up the possibility of retrieving the size and shape of the scattering object from fitting, as done in standard small-angle scattering analysis (Bressler et al., 2015 ▸).
Figure 6
Plots for measured (solid lines) and modelled (circles and dashed lines) intensity from a single voxel in two of the 16 azimuthal segments on the detector plane. The optimization was performed in 32 q values separately. For some q values the three-dimensional reciprocal-space maps are shown mapped onto a sphere. A black triangle points towards the intensity cap characteristic of the 65 nm collagen repeat distance.
SAXS tensor tomography
In order to extend this method to volumetric samples we combine SAXS with CT. In standard CT a scalar quantity, such as the sample absorption, is measured for each point within two-dimensional projections and the reconstruction is three dimensional. In such a case it is sufficient to measure projections at different sample orientations around a single rotation axis which is perpendicular to the X-ray beam propagation direction. For the case of SAXS one needs a reconstruction of the three-dimensional reciprocal-space map for each voxel, as described by the six-dimensional function in equation (3). Using the principles of invariant scattering along the direction of sample rotation (Feldkamp et al., 2009 ▸), Schaff et al. (2015 ▸) showed that for an ab initio reconstruction it is sufficient to measure SAXS patterns from all points of the sample, while sampling object orientations in the full steradians. To achieve this in the experiment a second rotation axis was introduced as schematically shown in Fig. 1 ▸(b). Raster scans of the whole sample, here also referred to as projections, are measured at different angles α and different tilt angles of this rotation axis, β. The object rotation matrix in each sample orientation n can be calculated by a rotation around y by an angle followed by a rotation around x by an angle , resulting in Because the sample is not perfectly aligned in the rotation centre of both rotation axes, the translational alignment of the measured projections has to be refined. For this purpose an X-ray absorption tomogram is reconstructed from the measured transmission images at β = 0°, using standard filtered back-projection algorithms. The sample transmission is measured simultaneously to the SAXS pattern using a photo-diode mounted on the beamstop, which blocks the direct unscattered beam and avoids damage to the detector. For each object orientation, (α, β), a projection from this absorption tomogram was calculated and used as a reference for alignment of the measured transmission images at the corresponding orientation. For this an efficient image registration approach based on selective up-sampling of the cross-correlation (Guizar-Sicairos et al., 2008 ▸) was used. If the sample has little contrast in the absorption measurement, alternatively the scattering intensity, averaged over φ in a chosen q range, can be used for this step.A human trabecular bone cylinder (sample B, Appendix B
) of about 1 mm3 was measured with a scanning step size in x and y of 25 µm. In total projections, i.e. different sample orientations , were measured with an angular step of = 4.5° between 0 and 180° and = 15° between −30 and 45°. The analysis was carried out following the procedure as described in §3 using a q range between 0.0379 and 0.0758 nm−1.In Fig. 7 ▸ the resulting main orientation of the bone ultrastructure is indicated by the direction of cylinders, the strength of the isotropic component by the length of cylinders, and the degree of orientation ρ by the colour. The latter is calculated by the ratio of the anisotropic component of to , namely For the reconstruction shown in Fig. 7 ▸, 830 000 SAXS patterns were used, which were acquired in 8 h total exposure time and an overall measurement time of 20.3 h including overhead from motor movements. More details about the measurement are given in Appendix B
. Minimizing measurement time can be tackled by changes in the hardware, e.g. reducing motor scanning overhead and faster detectors (Tinti et al., 2015 ▸). Another important aspect is to optimize spatial and angular sampling, as discussed in the following section.
Figure 7
Human trabecular bone (sample B). (a) Standard tomographic reconstruction based on the sample X-ray absorption. (b) Orientation of the bone ultrastructure as retrieved from SAXS tensor tomography. Colour, length and direction represent degree of orientation, isotropic component and main orientation of the collagen fibrils, respectively.
Dependence of reconstruction quality on angular sampling
In order to study the effect of the angular sampling of object orientations on the reconstruction, the optimization procedure for sample B was repeated using different subsets of the measured angular projections n. Whereas a smaller number of projections are used during these reconstructions, to compare the final quality of the reconstruction Fig. 8 ▸ shows the error with respect to all 240 projections. Therefore, the full data set is used as a ‘gold standard’ even when only a subset of the data is available in these test reconstructions. The whole data set is schematically shown in Fig. 8 ▸ (in red), where each point on the sphere represents a sample orientation and the measurements at the six values for β are shown as six meridional rows. For comparison, the projections from the full data set have been removed, keeping either the original = 4.5° (in blue), or = 15° (in black).
Figure 8
The error according to equation (4) between the modelled intensity and all measured projections (= 240) as a function of the number of projections used in the optimization. The two curves show the error metric for data sets where the projections are reduced by keeping constant either (blue) or (black). The spherical insets show the angular sampling schematically drawn on a sphere, where each object orientation (α, β) can be represented by a point on the hemisphere.
For the blue curve, we obtain 120 projections by taking a subset of the data corresponding to = 4.5° and = 30°. Furthermore, 40 projections were obtained by removing completely the tilt of the rotation angles and keeping = 4.5°. In contrast, for the curve in black we label the result with 120 projections for which we increased to 9° and kept the original = 15°, and furthermore tested 44 projections by increasing to 22.5° while keeping the original = 15°. That means the 40 projections (in blue) correspond to the sampling along only one rotation axis, similar to standard absorption-based CT, while the 44 projections (in black) correspond to an almost isotropic angular sampling ().The black curve with a more isotropic angular sampling results in a lower error compared with the corresponding points on the blue curve. The error using 120 projections around three tilt angles of the rotation axis in blue is even higher than for the 44-projection reconstruction with isotropic angular sampling (black), even though the latter has close to 60% fewer projections. This difference can be attributed to the angular distribution of these projections, where the 44-projection tomogram has almost isotropic angular sampling in α and β, and emphasizes the importance of adequate angular sampling of the full hemisphere of sample orientations.Following the black line, it is evident that the error metric with respect to the full data set remains constant for an extended range of sample rotations n, which means that the fit to the complete data set does not change much by reducing the number of projections, even to a fraction close to one third. This indicates that the data set was taken with significantly more projections than needed. One reason is that the choice of = 4.5° was based on the full diameter of the sample, not taking into account any sparsity of the sample, which could reduce angular sampling requirements. The spatial sparsity of the sample is actively used in the tensor tomography reconstruction through the mask . Another form of sparsity may arise from the fact that the bone ultrastructure exhibits domains in the order of a few hundred micrometres. In these reconstructions we did not use corresponding constraints. However this domain structure is evident even from the SAXS projections in Fig. 9 ▸. In §5.2 we show an approach to take advantage of this knowledge through regularization.
Figure 9
Comparison between measured two-dimensional scanning SAXS projections and the equivalent projection obtained from the reconstruction using subsets of the data corresponding to and 44 sample orientations. The colour wheel represents the main scattering orientation, the hue the scattering intensity, and the degree of orientation the colour saturation.
As a validation of the reconstruction, the two-dimensional projections from SAXS tensor reconstruction were computed and compared with the data; in other words we compared the measured scanning SAXS data for a projection in a given orientation of the sample, , with the corresponding projected intensity of the reconstruction, . The first column in Fig. 9 ▸ shows a representation of a scanning SAXS projection where the scattering intensity, degree of orientation and main scattering orientation are mapped to the image intensity, colour saturation and hue, respectively (Bunk et al., 2009 ▸). The colour-wheel inset relates the direction of the main scattering orientation to the particular hue. As already mentioned, it is evident that the trabecular bone sample exhibits domains within which the nanostructure orientation is spatially correlated. The projected intensity of the reconstructions is computed using equation (3) and shown in Fig. 9 ▸ for the case of the full data set () and for 44 projections. By examining Fig. 9 ▸ it can be seen that the experimental projections could be reliably reproduced with as few as projections for this sample, which would effectively have allowed for a reduction to one fifth of the scanning time and the deposited dose.
Regularization strategies
In some cases there is a tendency during a reconstruction to exacerbate high-spatial-frequency noise both in the coefficients as well as in the direction . To alleviate this problem a regularization method was implemented. Regularization is often used in optimization to better constrain ill posed or ill conditioned problems. The chosen approach for the coefficients follows a method akin to Grenander’s method of sieves (Grenander, 1981 ▸) by spatially convolving the gradient with respect to the spherical harmonics coefficients [equation (10)] with a three-dimensional Hamming window. We use windows of either or voxels. With this method the optimization solves first for the low and middle spatial frequencies while the high spatial frequencies are introduced last.For the regularization of the local preferential orientation, , the gradient convolution approach is not suitable because the direction is jointly represented by two parameters, and . In addition, the representation of an orientation using a vector has the inherent ambiguity that and would represent the same local orientation for a reciprocal-space map with a point symmetry. These characteristics do not pair well with a convolution. To penalize spurious variations of the orientation from neighbouring voxels a regularization term, , to the error metric was introduced in equation (5). The regularization term is based on the absolute value of the dot product between neighbouring , namely where are the Cartesian coordinate unit vectors, pointing in , respectively. μ is a free parameter that controls the relative strength of the regularization.The effect of this regularization on the orientation is shown in Fig. 10 ▸. A trabecular bone sample (sample C) of approximately 250 µm diameter was measured with a beam of 5 × 1.4 µm and a scan step size of 5 µm with a total of 333 angular projections, with an even distribution of projection angles = 7.5° and = 7.5° according to the discussion in §5.1. Fig. 10 ▸(a) shows an axial slice through the reconstruction of without regularization of the direction in which high-spatial-frequency fluctuations of the direction between neighbouring voxels are observed. Increasing the value of μ, Figs. 10 ▸(b)–10 ▸(f) demonstrate an increasing smoothness of the reconstruction of .
Figure 10
A cross section through the three-dimensional reconstruction of the local orientation, , is shown for (a) a reconstruction without regularization and (b)–(f) with different values of the regularization parameter μ. The three-dimensional orientation of was encoded through both hue and saturation, as indicated by the inset colour sphere.
In order to select an appropriate regularization parameter μ the L-curve technique was applied (Hansen, 1992 ▸; Li et al., 2003 ▸; Belge et al., 2002 ▸; Santos & Bassrei, 2007 ▸). The L-curve is a plot of the data error, , versus the regularization penalty term, , where each point corresponds to different values of the regularization strength, μ (see Fig. 11 ▸
a). The corner of the L-curve corresponds to a trade-off between a smooth solution with a high error metric and a solution with a small error but more high-frequency noise (Hansen, 1992 ▸). Fig. 11 ▸(b) shows the two terms of the error metric
versus the regularization parameter μ. The regularization parameter should be selected around the inflection point combined with a visual quality inspection of the solution (Fig. 10 ▸). Here we chose . This point is on the left side corner of the L-curve (red arrow in Fig. 11 ▸
a) because we prioritize a small error over a smooth solution.
Figure 11
(a) L-curve used to find an appropriate regularization parameter μ. (b) shows the dependence of the penalty term (left black axis) and of the of error metric (right blue axis) on the regularization parameter μ. These two values are combined in the L-curve. The red arrow and red dashed line indicate the regularization parameter selected for this trabecular bone sample as explained in the text.
A three-dimensional visualization of the resulting SAXS tensor tomography reconstruction, corresponding to Fig. 10 ▸(a), is shown in Fig. 12 ▸(b). The reconstruction using both regularization of the coefficients, with a Hamming window, and of the orientation with is shown in Fig. 12 ▸(c). The reconstruction without regularization shows substantial noise particularly in the orientations, and no clear domains are visible. This variation is not supported by the measured data, as shown in projections from different sample orientations () in Fig. 12 ▸(a). The regularization with as shown in Fig. 12 ▸(c) reduced the high-frequency noise without suppressing the different orientations found in the sample and leads to better defined regions of a higher degree of orientation (light green). The sample contains different domains of orientation, each spanning some tens of micrometres, similar to the sample shown in Figs. 7 ▸ and 9 ▸. The higher resolution obtained here with a smaller beam size of 5 × 1.4 µm enables us to resolve the transition region between the domains.
Figure 12
Orientation of the bone ultrastructure from a human trabecular bone (sample C). Four two-dimensional SAXS projections at different sample orientations are shown in (a), where the colour wheel represents the main scattering orientation, the hue the scattering intensity and the degree of orientation the colour saturation. The orientation of the bone ultrastructure retrieved from SAXS tensor tomography is shown in (b) and (c), where the colour represents the degree of orientation and the length of the isotropic component . (b) Reconstruction without regularization applied and (c) with regularization of the spherical harmonics coefficients and on the direction as described in the text.
Conclusion
SAXS tensor tomography aims at reconstructing the local three-dimensional reciprocal-space map for each volume element within a three-dimensional sample. This can be achieved through gradient-based optimization. An adequate numerical representation of the three-dimensional reciprocal-space map, for which only a few quantities or coefficients have to be recovered for each voxel, can be critical towards developing an approach that is efficient both in computational and measurement time. Liebi et al. (2015 ▸) introduced this reconstruction approach using spherical harmonics as a base to represent the reciprocal-space map and demonstrated it with a millimetre-sized sample of trabecular bone. The three-dimensional reciprocal-space map comprises information on the main orientation of the nanostructure for different q ranges and also its degree of orientation. The reciprocal-space map could further be used as input for fitting the underlying nanostructure, similarly to what has been done on two-dimensional SAXS data, for example to retrieve size parameters of the mineralized platelets in bone (Fratzl et al., 2005 ▸; Turunen et al., 2016 ▸).In this article we present a detailed description of the algorithm as well as a validation study to confirm the suitability of spherical harmonic coefficients to represent the three-dimensional reciprocal-space map of trabecular bone where the features of the mineralized collagen fibrils can be recovered. In order to reduce the number of coefficients that need to be optimized we provide for each voxel a parameterization of the spherical harmonic zenith direction, which provides directly the orientation of the main symmetry axis of the nanostructure in three dimensions and subsequently allows us to impose reciprocal-space symmetry constraints. Regularization strategies for both the coefficients and the orientation are introduced and described in detail. An important consideration is the distribution of projection angles for the measurements. By selectively removing angles the effect on the reconstruction is shown, which confirms that a uniform distribution of sample orientations is of significant benefit for the reconstruction quality.SAXS tensor tomography provides a technique that can probe three-dimensional nanostructure information in relatively large volumes, offering the unique chance to correlate spatial nanoscale features over several millimetres, i.e. separated over five or six orders of magnitude. The technique is applicable to a wide range of specimens in biology and materials science and also scalable. While the original demonstration was with 20 µm voxel size, by using microfocusing optics and improved scanning hardware this article demonstrated the technique to a spatial resolution of 5 µm. By suitable changes in optics and hardware the resolution can be adjusted to the application of interest.
Authors: Ang Li; Eric L Miller; Misha E Kilmer; Thomas J Brukilacchio; Tina Chaves; Jonathan Stott; Quan Zhang; Tao Wu; MaryAnn Chorlton; Richard H Moore; Daniel B Kopans; David A Boas Journal: Appl Opt Date: 2003-09-01 Impact factor: 1.980
Authors: Torben H Jensen; Martin Bech; Oliver Bunk; Maria Thomsen; Andreas Menzel; Audrey Bouchet; Géraldine Le Duc; Robert Feidenhans'l; Franz Pfeiffer Journal: Phys Med Biol Date: 2011-02-23 Impact factor: 3.609
Authors: Marios Georgiadis; Manuel Guizar-Sicairos; Alexander Zwahlen; Andreas J Trüssel; Oliver Bunk; Ralph Müller; Philipp Schneider Journal: Bone Date: 2014-10-13 Impact factor: 4.398
Authors: Carlos Sanchez-Cano; Ramon A Alvarez-Puebla; John M Abendroth; Tobias Beck; Robert Blick; Yuan Cao; Frank Caruso; Indranath Chakraborty; Henry N Chapman; Chunying Chen; Bruce E Cohen; Andre L C Conceição; David P Cormode; Daxiang Cui; Kenneth A Dawson; Gerald Falkenberg; Chunhai Fan; Neus Feliu; Mingyuan Gao; Elisabetta Gargioni; Claus-C Glüer; Florian Grüner; Moustapha Hassan; Yong Hu; Yalan Huang; Samuel Huber; Nils Huse; Yanan Kang; Ali Khademhosseini; Thomas F Keller; Christian Körnig; Nicholas A Kotov; Dorota Koziej; Xing-Jie Liang; Beibei Liu; Sijin Liu; Yang Liu; Ziyao Liu; Luis M Liz-Marzán; Xiaowei Ma; Andres Machicote; Wolfgang Maison; Adrian P Mancuso; Saad Megahed; Bert Nickel; Ferdinand Otto; Cristina Palencia; Sakura Pascarelli; Arwen Pearson; Oula Peñate-Medina; Bing Qi; Joachim Rädler; Joseph J Richardson; Axel Rosenhahn; Kai Rothkamm; Michael Rübhausen; Milan K Sanyal; Raymond E Schaak; Heinz-Peter Schlemmer; Marius Schmidt; Oliver Schmutzler; Theo Schotten; Florian Schulz; A K Sood; Kathryn M Spiers; Theresa Staufer; Dominik M Stemer; Andreas Stierle; Xing Sun; Gohar Tsakanova; Paul S Weiss; Horst Weller; Fabian Westermeier; Ming Xu; Huijie Yan; Yuan Zeng; Ying Zhao; Yuliang Zhao; Dingcheng Zhu; Ying Zhu; Wolfgang J Parak Journal: ACS Nano Date: 2021-03-02 Impact factor: 15.881
Authors: Weijie Tao; Yongjin Sung; Sally Ji Who Kim; Qiu Huang; Grant T Gullberg; Youngho Seo; Michael Fuller Journal: Med Phys Date: 2021-08-18 Impact factor: 4.506
Authors: Els Fieremans; Markus Rudin; Marios Georgiadis; Aileen Schroeter; Zirui Gao; Manuel Guizar-Sicairos; Marianne Liebi; Christoph Leuze; Jennifer A McNab; Aleezah Balolia; Jelle Veraart; Benjamin Ades-Aron; Sunglyoung Kim; Timothy Shepherd; Choong H Lee; Piotr Walczak; Shirish Chodankar; Phillip DiGiacomo; Gergely David; Mark Augath; Valerio Zerbi; Stefan Sommer; Ivan Rajkovic; Thomas Weiss; Oliver Bunk; Lin Yang; Jiangyang Zhang; Dmitry S Novikov; Michael Zeineh Journal: Nat Commun Date: 2021-05-19 Impact factor: 14.919
Authors: Tilman A Grünewald; Marianne Liebi; Nina K Wittig; Andreas Johannes; Tanja Sikjaer; Lars Rejnmark; Zirui Gao; Martin Rosenthal; Manuel Guizar-Sicairos; Henrik Birkedal; Manfred Burghammer Journal: Sci Adv Date: 2020-06-12 Impact factor: 14.136
Authors: Fredrik K Mürer; Basab Chattopadhyay; Aldritt Scaria Madathiparambil; Kim Robert Tekseth; Marco Di Michiel; Marianne Liebi; Magnus B Lilledahl; Kristin Olstad; Dag W Breiby Journal: Sci Rep Date: 2021-01-25 Impact factor: 4.379
Authors: Paolino De Falco; Richard Weinkamer; Wolfgang Wagermaier; Chenghao Li; Tim Snow; Nicholas J Terrill; Himadri S Gupta; Pawan Goyal; Martin Stoll; Peter Benner; Peter Fratzl Journal: J Appl Crystallogr Date: 2021-03-03 Impact factor: 4.868
Authors: V Lutz-Bueno; C Arboleda; L Leu; M J Blunt; A Busch; A Georgiadis; P Bertier; J Schmatz; Z Varga; P Villanueva-Perez; Z Wang; M Lebugle; C David; M Stampanoni; A Diaz; M Guizar-Sicairos; A Menzel Journal: J Appl Crystallogr Date: 2018-09-10 Impact factor: 3.304
Authors: Sheetal R Inamdar; Ettore Barbieri; Nicholas J Terrill; Martin M Knight; Himadri S Gupta Journal: Acta Biomater Date: 2019-07-30 Impact factor: 8.947