Jian Zhong1, Zhenqing Ye2, Samuel W Lenz1, Chad R Clark1, Adil Bharucha3, Gianrico Farrugia4, Keith D Robertson5,6,7, Zhiguo Zhang8, Tamas Ordog3,4,7,9, Jeong-Heon Lee10,11,12.
Abstract
BACKGROUND: Chromatin immunoprecipitation-sequencing (ChIP-seq) is a widely used epigenetic approach for investigating genome-wide protein-DNA interactions in cells and tissues. The approach has been relatively well established but several key steps still require further improvement. As a part of the procedure, immnoprecipitated DNA must undergo purification and library preparation for subsequent high-throughput sequencing. Current ChIP protocols typically yield nanogram quantities of immunoprecipitated DNA mainly depending on the target of interest and starting chromatin input amount. However, little information exists on the performance of reagents used for the purification of such minute amounts of immunoprecipitated DNA in ChIP elution buffer and their effects on ChIP-seq data. Here, we compared DNA recovery, library preparation efficiency, and ChIP-seq results obtained with several commercial DNA purification reagents applied to 1 ng ChIP DNA and also investigated the impact of conditions under which ChIP DNA is stored. <br> RESULTS: We compared DNA recovery of ten commercial DNA purification reagents and phenol/chloroform extraction from 1 to 50 ng of immunopreciptated DNA in ChIP elution buffer. The recovery yield was significantly different with 1 ng of DNA while similar in higher DNA amounts. We also observed that the low nanogram range of purified DNA is prone to loss during storage depending on the type of polypropylene tube used. The immunoprecipitated DNA equivalent to 1 ng of purified DNA was subject to DNA purification and library preparation to evaluate the performance of four better performing purification reagents in ChIP-seq applications. Quantification of library DNAs indicated the selected purification kits have a negligible impact on the efficiency of library preparation. The resulting ChIP-seq data were comparable with the dataset generated by ENCODE consortium and were highly correlated between the data from different purification reagents. <br> CONCLUSIONS: This study provides comparative data on commercial DNA purification reagents applied to nanogram-range immunopreciptated ChIP DNA and evidence for the importance of storage conditions of low nanogram-range purified DNA. We verified consistent high performance of a subset of the tested reagents. These results will facilitate the improvement of ChIP-seq methodology for low-input applications.Entities:
Keywords: ChIP-seq; DNA purification; DNA storage; Nanogram DNA
Mesh:
Substances:
Year: 2017 PMID: 29268714 PMCID: PMC5740926 DOI: 10.1186/s12864-017-4371-5
Source DB: PubMed Journal: BMC Genomics ISSN: 1471-2164 Impact factor: 3.969
Fig. 1DNA purification reagents vary in their ability to recover low amounts of DNA from de-crosslinked chromatin. a Recovered DNA amount by different DNA purification reagents from de-crosslinked chromatin. De-crosslinked chromatin estimated to include 1 ng range DNA in ChIP elution buffer was purified following the manufacturer’s instructions. The data were generated from triplicate DNA samples derived from three independent preparations. Zy, ChIP DNA Clean & Concentrator™ (Zymo Research); Pr, Wizard® SV Gel and PCR Clean-Up System (Promega); Th, GeneJET PCR Purification Kit (Thermo Fisher Scientific); In, PureLink® PCR Purification Kit (Invitrogen); Ne, Monarch® PCR & DNA Cleanup Kit (New England Biolabs); Am, Chromatin IP DNA Purification Kit (Active Motif); Qp, QIAquick PCR Purification Kit (Qiagen); Qm, MinElute PCR Purification Kit (Qiagen); Ba, Agencourt AMPure XP kit (Beckman, chromatin to beads ratio from 1:1.25 to 1:2); Br, RNAClean™ XP kit (Beckman, chromatin to beads ratio from 1:1.25 to 1:2); PC, phenol/chloroform extraction. b Interference of PCR amplification by purified eluent of purification reagents. 9 μL eluent was mixed with 1 μL 166 bp of Drosophila probe DNA (0.0001 ng), and the resulting mixture was used as the template in 20 μl of real-time PCR reaction. The Ct value for Drosophila probe DNA from TE buffer was set as 100%. The experiment was repeated 3 times using de-crosslinked chromatin estimated to include 1 ng of DNA. c Size profiles of DNA purified by different reagents. The DNAs purified from de-crosslinked chromatin estimated to include 50 ng range DNA was analyzed by AATI Fragment Analyzer. DNA size (bp) is shown
Fig. 2Storage condition of purified ChIP DNA is important. Purified ChIP DNA was adjusted to a concentration of 1 ng/μL (a) or 0.1 ng/μL (b), aliquoted into 4 different types of microcentrifuge tubes in 15 μL volume, and stored at −20 °C. DNA was quantified using Qubit dsDNA High Sensitivity assay at the indicated time points and expressed as a percentage of the amount measured at day 0. Three independent DNA samples were used in the experiment and DNA concentration from five tubes were measured at each time point. MaxyClear, Axygen® 1.7 mL MaxyClear Snaplock Microcentrifuge Tube; LoBind, Eppendorf DNA LoBind Snap Cap PCR Tube; Siliconized, Fisherbrand™ Siliconized Low-Retention Microcentrifuge Tube; Premium, Fisherbrand™ Premium Microcentrifuge Tube
Fig. 3Highly correlated ChIP-seq data are generated from the DNAs purified by different purification reagents. a Schematic diagram of the experimental design. b Snapshot image of ChIP-seq results generated with different purification reagents as identified in Fig. 1. ChIP-seq results were visualized in a 542 kb genomic region using the Integrative Genomics Viewer [8, 9]. ENB and ENW indicate the ENCODE dataset from Broad Institute and University of Washington, respectively. St, data generated by our standard ChIP-seq protocol. c Scatter plots showing the correlation between the internal reference ChIP-seq data obtained with standard protocol for the lab (St) and the corresponding datasets generated with different purification reagents. The genome was divided into bins of 5 kb for H3K4me3 and 100 kb for H3K27me3, and the number of mapped reads in the individual bins was calculated. r, Pearson correlation coefficient. Top and bottom panels show H3K4me3 and H3K27me3 ChIP-seq data, respectively