Literature DB >> 29267522

Three-Dimensional Finite Element Analysis of Varying Diameter and Connection Type in Implants with High Crown-Implant Ratio.

Sandra Lúcia Dantas de Moraes1, Fellippo Ramos Verri2, Joel Ferreira Santiago3, Daniel Augusto de Faria Almeida4, Cleidiel Aparecido Araujo Lemos2, Jéssica Marcela de Luna Gomes2, Eduardo Piza Pellizzer2.   

Abstract

The aim of this study was to evaluate the effect of varying the diameter, connection type and loading on stress distribution in the cortical bone for implants with a high crown-implant ratio. Six 3D models were simulated with the InVesalius, Rhinoceros 3D 4.0 and SolidWorks 2011 software programs. Models were composed of bone from the posterior mandibular region; they included an implant of 8.5 mm length, diameter Ø 3.75 mm or Ø 5.00 mm and connection types such as external hexagon (EH), internal hexagon (IH) and Morse taper (MT). Models were processed using the Femap 11.2 and NeiNastran 11.0 programs and by using an axial force of 200 N and oblique force of 100 N. Results were recorded in terms of the maximum principal stress. Oblique loading showed high stress in the cortical bone compared to that shown by axial loading. The results showed that implants with a wide diameter showed more favorable stress distribution in the cortical bone region than regular diameter, regardless of the connection type. Morse taper implants showed better stress distribution compared to other connection types, especially in the oblique loading. Thus, oblique loading showed higher stress concentration in cortical bone tissue when compared with axial loading. Wide diameter implant was favorable for improved stress distribution in the cortical bone region, while Morse taper implants showed lower stress concentration than other connections.

Mesh:

Substances:

Year:  2018        PMID: 29267522     DOI: 10.1590/0103-6440201801746

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  4 in total

1.  Complete mechanical characterization of an external hexagonal implant connection: in vitro study, 3D FEM, and probabilistic fatigue.

Authors:  María Prados-Privado; Sérgio A Gehrke; Rosa Rojo; Juan Carlos Prados-Frutos
Journal:  Med Biol Eng Comput       Date:  2018-06-11       Impact factor: 2.602

2.  Comparative analysis of stress distribution in one-piece and two-piece implants with narrow and extra-narrow diameters: A finite element study.

Authors:  Fabricia Teixeira Barbosa; Luiz Carlos Silveira Zanatta; Edélcio de Souza Rendohl; Sergio Alexandre Gehrke
Journal:  PLoS One       Date:  2021-02-04       Impact factor: 3.240

3.  Comparison of stresses in monoblock tilted implants and conventional angled multiunit abutment-implant connection systems in the all-on-four procedure.

Authors:  Özge Özdal Zincir; Ateş Parlar
Journal:  BMC Oral Health       Date:  2021-12-16       Impact factor: 2.757

4.  Biomechanical finite element analysis of short-implant-supported, 3-unit, fixed CAD/CAM prostheses in the posterior mandible.

Authors:  Lana Zupancic Cepic; Martin Frank; Andreas Reisinger; Dieter Pahr; Werner Zechner; Andreas Schedle
Journal:  Int J Implant Dent       Date:  2022-02-11
  4 in total