Use of an antimicrobial pouch/envelope in the treatment of Twiddler's syndrome.

Moses Osoro1, William Lorson1, Jeffrey B Hirsh2, William Jeremy Mahlow2.   

Abstract

BACKGROUND: "Twiddler's syndrome" occurs when a patient consciously or subconsciously manipulates their pacemaker/defibrillator pulse generator, often resulting in lead dislodgement and device system malfunction. Once dislodgement has occurred, corrective measures include resecuring the system to the pectoralis fascia with redundant anchoring sutures. Unfortunately, patients with Twiddler's syndrome tend to have a high rate of recurrence. This study presents a case series of patients with Twiddler's syndrome and evaluates the strategy of using a nonabsorbable antimicrobial pouch to prevent recurrent lead dislodgement events.
METHODS: Pacemaker and defibrillator operative reports were reviewed at a single institution over a time period of 16 years. Historical, fluoroscopic, and intraoperative findings were used to identify 21 patients with strong evidence for Twiddler's syndrome. Patient charts were retrospectively analyzed, and a cohort of 13 patients who received a nonabsorbable antimicrobial pouch was compared to a cohort of eight patients who received other corrective measures.
RESULTS: The rate of "retwiddling" events was 0% in the antimicrobial pouch group versus 50% in the suture-only group (P < 0.05).
CONCLUSIONS: Among patients requiring device system revision for Twiddler's syndrome, the use of nonabsorbable antimicrobial pouches was associated with significantly fewer recurrences of lead dislodgement events.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  CRT; Twiddler's syndrome; complications; defibrillation-ICD; pacing

Mesh:

Substances:

Year:  2018        PMID: 29266324     DOI: 10.1111/pace.13259

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  7 in total

1.  Erosive Twiddler's Syndrome: A Severe Case with Externalization of the Pacemaker.

Authors:  Ryan Stuart; Zachary Gilbert; Damian N Valencia
Journal:  Cureus       Date:  2020-03-29

2.  Delayed management of atrial lead dislodgment after pacemaker implantation: a case report.

Authors:  Fu Guan; Guangping Li; Yong Liu; Xing Gao; Rui Zhou
Journal:  J Med Case Rep       Date:  2021-01-14

3.  Absorbable antibacterial envelope in the surgical management of Twiddler's syndrome in a patient with gastric electric stimulator: a case report.

Authors:  Miranda Haslam; Henry P Parkman; Roman V Petrov
Journal:  Dig Med Res       Date:  2020-12

Review 4.  Surgical management of "Twiddler syndrome" in patients with deep brain stimulation: a technical note and review of the literature.

Authors:  Z Krause Molle; P Slotty; J Vesper
Journal:  Acta Neurochir (Wien)       Date:  2022-02-25       Impact factor: 2.216

5.  A case of twiddler's syndrome with a subcutaneous implantable cardioverter-defibrillator.

Authors:  Chengyue Jin; Sei Iwai; Jason Jacobson; Aileen Ferrick
Journal:  HeartRhythm Case Rep       Date:  2022-08-15

6.  Risk Mitigation of Pacemaker Pocket Erosion in Thin Patients.

Authors:  Bert Vandenberk; Kyle Murray; Jacques Rizkallah
Journal:  CJC Open       Date:  2022-03-09

7.  Twiddler's Syndrome: An Unusual Cause of Repeated Shocks by Implantable Cardioverter-Defibrillator in an Asymptomatic Patient.

Authors:  Ahmad Jabri; Zenab Laiq; Yassar Nabeel
Journal:  Heart Views       Date:  2019 Jul-Sep
  7 in total