Literature DB >> 2926463

Sampling intervals for clinical monitoring of variables during anesthesia.

J S Gravenstein1, A de Vries, J E Beneken.   

Abstract

Although five minutes is the sampling interval mentioned by the American Society of Anesthesiologists for monitoring blood pressure and heart rate during anesthesia, most patients are monitored more closely by continuous auscultation and with the help of automated instruments. Yet this difference between the interval recommended and that actually used indicates that sampling intervals are not defined clearly enough. Therefore, we present three methods with which to determine sampling intervals during monitoring. To explore the feasibility of these methods we examined data gathered every 7.5 seconds during three typical, noncatastrophic physiologic perturbations induced in an anesthetized dog. We chose hypercapnia secondary to rebreathing, hypotension secondary to deep anesthesia, and hypoxemia secondary to a low concentration of inspired oxygen as realistic examples of what can occur during operation and anesthesia. We studied three variables: respired carbon dioxide, femoral arterial blood pressure, and oxygen saturation of hemoglobin (pulse oximeter). The data obtained during monitoring were subjected to three methods of analysis: (1) recording of sets of data, with various starting times, at five-minute intervals only (moving grid); (2) Fourier analysis; and (3) analysis of slopes. For the data of the experiment, the Fourier analysis yielded, on average, longer sampling intervals than did the analysis of slopes.

Entities:  

Mesh:

Year:  1989        PMID: 2926463     DOI: 10.1007/BF01618365

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  1 in total

1.  Apneic oxygenation in man.

Authors:  M J FRUMIN; R M EPSTEIN; G COHEN
Journal:  Anesthesiology       Date:  1959 Nov-Dec       Impact factor: 7.892

  1 in total
  9 in total

1.  Real time data acquisition: experience with the Medical Information Bus (MIB).

Authors:  R M Gardner; W L Hawley; T D East; T A Oniki; H F Young
Journal:  Proc Annu Symp Comput Appl Med Care       Date:  1991

2.  Computerization of anesthesia information management.

Authors:  J H Eichhorm; D W Edsall
Journal:  J Clin Monit       Date:  1991-01

3.  A new system to record reliable pulse oximetry data from the Nellcor N-200 and its applications in studies of variability in infant oxygenation.

Authors:  D Sprague; M S Richardson; J W Baish; J S Kemp
Journal:  J Clin Monit       Date:  1996-01

4.  Lack of documentation of severe transient bradycardia by an automated anesthesia record.

Authors:  A Feingold; A Galindo; H E Feingold
Journal:  J Clin Monit       Date:  1994-11

5.  What is heart rate, anyway?

Authors:  F E Block
Journal:  J Clin Monit       Date:  1994-11

6.  Comparison of four methods of automated recording of physiologic data at one minute intervals.

Authors:  P Gregorini
Journal:  J Clin Monit       Date:  1996-07

Review 7.  Patient data management systems in anaesthesia: an emerging technology.

Authors:  Y G Weiss; S Cotev; B Drenger; R Katzenelson
Journal:  Can J Anaesth       Date:  1995-10       Impact factor: 5.063

8.  Sampling intervals to record severe hypotensive and hypoxic episodes in anesthetised patients.

Authors:  J L Derrick; D J Bassin
Journal:  J Clin Monit Comput       Date:  1998-07       Impact factor: 2.502

9.  Adequate interval for the monitoring of vital signs during endotracheal intubation.

Authors:  J Y Min; H I Kim; S J Park; H Lim; J H Song; H J Byon
Journal:  BMC Anesthesiol       Date:  2017-08-22       Impact factor: 2.217

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.