Literature DB >> 2926044

Pacemaker-implantation complication rates: an analysis of some contributing factors.

V Parsonnet1, A D Bernstein, B Lindsay.   

Abstract

An examination of 632 consecutive pacemaker implantations performed at a single institution by 29 implanting physicians over a 5 year period was made to determine which factors affected the 37 perioperative complications experienced. The introducer method of vein access contributed significantly to the complication rate, which was also related to the number of physician implanters on the staff and the makeup of the implantation teams. Of greatest interest was the substantially large incidence of complications experienced by implanters who performed fewer than 12 implantations per year, and particularly the incidence of lead-related complications.

Mesh:

Year:  1989        PMID: 2926044     DOI: 10.1016/0735-1097(89)90236-2

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  19 in total

1.  Complications of dual chamber pacemaker implantation in the elderly. Pacemaker Selection in the Elderly (PASE) Investigators.

Authors:  M S Link; N A Estes; J J Griffin; P J Wang; J D Maloney; J B Kirchhoffer; G F Mitchell; J Orav; L Goldman; G A Lamas
Journal:  J Interv Card Electrophysiol       Date:  1998-06       Impact factor: 1.900

Review 2.  Clinical competence in electrophysiological techniques.

Authors:  R W Campbell; R Charles; J C Cowan; C Garratt; J M McComb; J Morgan; E Rowland; R Sutton
Journal:  Heart       Date:  1997-10       Impact factor: 5.994

Review 3.  Radiology of cardiac devices and their complications.

Authors:  J Dipoce; A Bernheim; H Spindola-Franco
Journal:  Br J Radiol       Date:  2014-11-20       Impact factor: 3.039

4.  Piercing the left lung with a pacemaker lead, an uncommon complication.

Authors:  A A Hassan; J Widdershoven; M A Molenaar; J Winter
Journal:  Neth Heart J       Date:  2004-12       Impact factor: 2.380

Review 5.  Subcutaneous chronic implantable defibrillation systems in humans.

Authors:  Riccardo Cappato; Warren M Smith; Margaret A Hood; Ian G Crozier; Luc Jordaens; Stefan G Spitzer; Andrey V Ardashev; Lucas Boersma; Pierpaolo Lupo; Andrew A Grace; Gust H Bardy
Journal:  J Interv Card Electrophysiol       Date:  2012-03-17       Impact factor: 1.900

6.  Pacemaker insertion.

Authors:  Maria Kotsakou; Ioannis Kioumis; George Lazaridis; Georgia Pitsiou; Sofia Lampaki; Antonis Papaiwannou; Anastasia Karavergou; Kosmas Tsakiridis; Nikolaos Katsikogiannis; Ilias Karapantzos; Chrysanthi Karapantzou; Sofia Baka; Ioannis Mpoukovinas; Vasilis Karavasilis; Aggeliki Rapti; Georgia Trakada; Athanasios Zissimopoulos; Konstantinos Zarogoulidis; Paul Zarogoulidis
Journal:  Ann Transl Med       Date:  2015-03

7.  Use of a coronary sinus guiding sheath for placement of right ventricular lead in abnormal venous anatomy: a report of 2 cases.

Authors:  G Vivek; Ranjan K Shetty; Umesh M Pai; Krishnananda Nayak
Journal:  BMJ Case Rep       Date:  2012-11-15

8.  Implantable electrophysiologic cardiac device infections: a risk factor analysis.

Authors:  D Raad; J Irani; E G Akl; S Choueiri; E Azar; J Abboud; C Afif
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2012-08-25       Impact factor: 3.267

9.  Pacemaker implantation in the extreme elderly.

Authors:  Robert T Stevenson; David Lugg; Robert Gray; Douglas Hollis; Michelle Stoner; Jeffrey L Williams
Journal:  J Interv Card Electrophysiol       Date:  2011-09-23       Impact factor: 1.900

10.  Long term complications in single and dual chamber pacing are influenced by surgical experience and patient morbidity.

Authors:  F Eberhardt; F Bode; H Bonnemeier; F Boguschewski; M Schlei; W Peters; U K H Wiegand
Journal:  Heart       Date:  2005-04       Impact factor: 5.994

View more