Necessary additional steps in ultrasound guided central venous catheter placement: getting to the heart of the matter.

Thei S Steenvoorden1, Jasper M Smit2, Mark E Haaksma2, Pieter R Tuinman2.   

Abstract

Entities:  

Keywords:  Central venous catheter; Intensive care; Ultrasound; Ultrasound guidance

Mesh:

Year:  2017        PMID: 29258614      PMCID: PMC5735926          DOI: 10.1186/s13054-017-1900-1

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


× No keyword cloud information.
With great interest we read the recent article on ultrasound (US)-guided central venous catheter (CVC) placement by Saugel et al. [1] and we completely agree with the authors on the importance of US guidance in CVC placement. However, we do believe that their protocol is incomplete. The authors’ recommendations rely solely on wire, needle, and CVC position confirmation in the entry vein, which does not provide the physician with information regarding correct CVC position or placement-associated complications. First of all, the procedure’s success rate can be increased by adding guidewire confirmation in the right atrium. Research has shown that US confirmation of the guidewire’s position in the right atrium via the subcostal acoustic window is a reliable tool for assuring correct CVC placement. The guidewire should be moved into the right atrium until the tip can be visualized as a hyperechogenic line on the US image. The wire should then be pulled back until the tip is no longer visible through this acoustic window. Inserting the CVC after these steps results in a very reliable position [2, 3]. Secondly, even though it is beyond the scope of the research, we would like to emphasize that ultrasonography can also be used to accurately diagnose CVC misplacement and related complications such as pneumothorax. The CVC can unwantedly loop or migrate into various veins, for example, contra- or ipsilateral situated veins such as the subclavian or internal jugular veins [4]. Thus, in order to accurately determine malposition after the procedure, bilateral subclavian views should be integrated in the diagnostic US protocol as well. Furthermore, US signs, including “lung sliding”, “B-lines”, “seashore sign”, and the “lung point”, can help in the diagnosis of pneumothorax. Thereby, US imaging has been shown to be an even more accurate tool than chest X-ray in confirming this diagnosis [5]. A complete and thorough US protocol, including guidewire confirmation in the right atrium and post-procedural scanning for complications, will not only contribute to reducing periprocedural complications but will also make the still obligatory follow-up through chest X-ray obsolete, resulting in lower costs and less exposure to radiation for the patient.
  5 in total

1.  Guidewire localization by transthoracic echocardiography during central venous catheter insertion: a periprocedural method to evaluate catheter placement.

Authors:  Jerome Bedel; Fabrice Vallée; Arnaud Mari; Beatrice Riu; Benjamin Planquette; Thomas Geeraerts; Michèle Génestal; Vincent Minville; Olivier Fourcade
Journal:  Intensive Care Med       Date:  2013-09-20       Impact factor: 17.440

2.  The utility of transthoracic echocardiography to confirm central line placement: an observational study.

Authors:  Ramiro Arellano; Aliya Nurmohamed; Amir Rumman; Andrew G Day; Brian Milne; Rachel Phelan; Robert Tanzola
Journal:  Can J Anaesth       Date:  2014-01-23       Impact factor: 5.063

3.  Ultrasound-Guided Placement of Central Venous Port Systems via the Right Internal Jugular Vein: Are Chest X-Ray and/or Fluoroscopy Needed to Confirm the Correct Placement of the Device?

Authors:  Michelangelo Miccini; Diletta Cassini; Matteo Gregori; Sergio Gazzanelli; Simone Cassibba; Daniele Biacchi
Journal:  World J Surg       Date:  2016-10       Impact factor: 3.352

Review 4.  Ultrasound-guided central venous catheter placement: a structured review and recommendations for clinical practice.

Authors:  Bernd Saugel; Thomas W L Scheeren; Jean-Louis Teboul
Journal:  Crit Care       Date:  2017-08-28       Impact factor: 9.097

Review 5.  Pleural ultrasonography versus chest radiography for the diagnosis of pneumothorax: review of the literature and meta-analysis.

Authors:  Saadah Alrajab; Asser M Youssef; Nuri I Akkus; Gloria Caldito
Journal:  Crit Care       Date:  2013-09-23       Impact factor: 9.097

  5 in total
  1 in total

Review 1.  Bedside ultrasound to detect central venous catheter misplacement and associated iatrogenic complications: a systematic review and meta-analysis.

Authors:  Jasper M Smit; Reinder Raadsen; Michiel J Blans; Manfred Petjak; Peter M Van de Ven; Pieter R Tuinman
Journal:  Crit Care       Date:  2018-03-13       Impact factor: 9.097

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.