Literature DB >> 29255745

Diagnostic Accuracy of Controlled Attenuation Parameter for Detecting Hepatic Steatosis in Patients with Chronic Liver Disease.

Patrícia Andrade1, Susana Rodrigues1, Eduardo Rodrigues-Pinto1, Rui Gaspar1, Joanne Lopes2, Susana Lopes1, Guilherme Macedo1.   

Abstract

INTRODUCTION: Controlled attenuation parameter (CAP), measured by transient elastography, has been suggested as a noninvasive method for the detection and quantification of steatosis. We aimed to assess the accuracy of CAP to detect steatosis in patients with chronic liver disease (CLD) compared with liver histology and to evaluate factors that correlate with the CAP value.
METHODS: Patients with CLD who underwent liver biopsy and simultaneous CAP determination were consecutively enrolled. CAP was measured using the M probe of FibroScan® (Echosens, Paris, France). Histologically, steatosis was categorized as absent (S0: <5%), mild (S1: 5-33%), moderate (S2: 34-66%) and severe (S3: >66% of all hepatocytes).
RESULTS: We analyzed 159 patients with CLD (61% men, mean age 47.9 ± 12.9 years). We found a positive correlation between CAP and steatosis in histology (rs = 0.869, p < 0.001), arterial hypertension (rs = 0.222, p = 0.005), type 2 diabetes mellitus (rs = 0.279, p < 0.001), body mass index (BMI; rs = 0.533, p < 0.001), total cholesterol (rs = 0.442, p < 0.001), triglycerides (rs = 0.272, p = 0.001), and non-alcoholic fatty liver disease (NAFLD; rs = 0.588, p < 0.001). In the multivariate analysis, BMI >25 (odds ratio [OR] 48.4, 95% confidence interval [CI] 23.78-72.95, p < 0.001), serum total cholesterol (OR 3.803, 95% CI 2.203-13.889, p = 0.008), and NAFLD etiology (OR 40.8, 95% CI 15.01-66.66, p = 0.002) were independently associated with higher CAP values. We did not find any significant correlation between CAP and the grade of necroinflammatory activity (rs = 0.063, p = 0.808) or fibrosis (rs = 0.071, p = 0.713) in histology and with alanine aminotransferase (rs = 0.190, p = 0.356) or aspartate aminotransferase (rs = 0.117, p = 0.142). Optimal CAP cutoff values for detecting steatosis ≥S1, ≥S2, and ≥S3 were 206.5, 232.5, and 282.5 dB/m, respectively. CAP performance was 0.822, 0.956, and 0.976 for diagnosing steatosis ≥S1, ≥S2, and ≥S3, respectively.
CONCLUSIONS: CAP had an excellent diagnostic accuracy for the detection of steatosis in diverse CLD patients. A CAP value cutoff of <282.5 dB/m excludes severe steatosis ≥S3 with an accuracy of 98%.

Entities:  

Keywords:  Chronic liver disease; Controlled attenuation parameter; Liver biopsy; Steatosis; Transient elastography

Year:  2016        PMID: 29255745      PMCID: PMC5729946          DOI: 10.1159/000453364

Source DB:  PubMed          Journal:  GE Port J Gastroenterol        ISSN: 2387-1954


  31 in total

1.  Novel controlled attenuation parameter for noninvasive assessment of steatosis using Fibroscan(®): validation in chronic hepatitis C.

Authors:  M Sasso; I Tengher-Barna; M Ziol; V Miette; C Fournier; L Sandrin; R Poupon; A-C Cardoso; P Marcellin; C Douvin; V de Ledinghen; J-C Trinchet; M Beaugrand
Journal:  J Viral Hepat       Date:  2011-10-13       Impact factor: 3.728

2.  A position statement on NAFLD/NASH based on the EASL 2009 special conference.

Authors:  Vlad Ratziu; Stefano Bellentani; Helena Cortez-Pinto; Chris Day; Giulio Marchesini
Journal:  J Hepatol       Date:  2010-05-07       Impact factor: 25.083

3.  Controlled attenuation parameter (CAP): a novel VCTE™ guided ultrasonic attenuation measurement for the evaluation of hepatic steatosis: preliminary study and validation in a cohort of patients with chronic liver disease from various causes.

Authors:  Magali Sasso; Michel Beaugrand; Victor de Ledinghen; Catherine Douvin; Patrick Marcellin; Raoul Poupon; Laurent Sandrin; Véronique Miette
Journal:  Ultrasound Med Biol       Date:  2010-09-27       Impact factor: 2.998

4.  Prevalence of and risk factors for hepatic steatosis in Northern Italy.

Authors:  S Bellentani; G Saccoccio; F Masutti; L S Crocè; G Brandi; F Sasso; G Cristanini; C Tiribelli
Journal:  Ann Intern Med       Date:  2000-01-18       Impact factor: 25.391

5.  Diagnostic accuracy of controlled attenuation parameter measured by transient elastography for the non-invasive assessment of liver steatosis: a prospective study.

Authors:  Monica Lupșor-Platon; Diana Feier; Horia Stefănescu; Attila Tamas; Emil Botan; Zeno Sparchez; Anca Maniu; Radu Badea
Journal:  J Gastrointestin Liver Dis       Date:  2015-03       Impact factor: 2.008

6.  Diagnostic performance of controlled attenuation parameter for predicting steatosis grade in chronic hepatitis B.

Authors:  Ana C Cardoso; Michel Beaugrand; Victor de Ledinghen; Catherine Douvin; Raoul Poupon; Jean-Claude Trinchet; Marianne Ziol; Pierre Bedossa; Patrick Marcellin
Journal:  Ann Hepatol       Date:  2015 Nov-Dec       Impact factor: 2.400

7.  Nonalcoholic steatohepatitis is the second leading etiology of liver disease among adults awaiting liver transplantation in the United States.

Authors:  Robert J Wong; Maria Aguilar; Ramsey Cheung; Ryan B Perumpail; Stephen A Harrison; Zobair M Younossi; Aijaz Ahmed
Journal:  Gastroenterology       Date:  2014-11-25       Impact factor: 22.682

Review 8.  Non-invasive assessment and quantification of liver steatosis by ultrasound, computed tomography and magnetic resonance.

Authors:  Nina F Schwenzer; Fabian Springer; Christina Schraml; Norbert Stefan; Jürgen Machann; Fritz Schick
Journal:  J Hepatol       Date:  2009-06-11       Impact factor: 25.083

9.  The diagnostic accuracy of US, CT, MRI and 1H-MRS for the evaluation of hepatic steatosis compared with liver biopsy: a meta-analysis.

Authors:  Anneloes E Bohte; Jochem R van Werven; Shandra Bipat; Jaap Stoker
Journal:  Eur Radiol       Date:  2010-07-31       Impact factor: 5.315

10.  Factors affecting the accuracy of controlled attenuation parameter (CAP) in assessing hepatic steatosis in patients with chronic liver disease.

Authors:  Kyu Sik Jung; Beom Kyung Kim; Seung Up Kim; Young Eun Chon; Kyeong Hyeon Chun; Kyung Hyun Cheon; Sung Bae Kim; Sang Hoon Lee; Sung Soo Ahn; Jun Yong Park; Do Young Kim; Sang Hoon Ahn; Young Nyun Park; Kwang-Hyub Han
Journal:  PLoS One       Date:  2014-06-05       Impact factor: 3.240

View more
  5 in total

1.  Effect of silibinin capsules combined with lifestyle modification on hepatic steatosis in patients with chronic hepatitis B.

Authors:  Duo-Duo Lv; You-Juan Wang; Meng-Lan Wang; En-Qiang Chen; Ya-Chao Tao; Dong-Mei Zhang; Hong Tang
Journal:  Sci Rep       Date:  2021-01-12       Impact factor: 4.379

2.  Correlation Between Psoriasis Severity and Nonalcoholic Fatty Liver Disease Degree Measured Using Controlled Attenuation Parameter.

Authors:  Nico Gandha; Larisa Paramitha Wibawa; Tjut Nurul Alam Jacoeb; Andri Sanityoso Sulaiman
Journal:  Psoriasis (Auckl)       Date:  2020-10-20

3.  Effect of Meal Ingestion on Liver Stiffness and Controlled Attenuation Parameter.

Authors:  Marco Silva; Pedro Costa Moreira; Armando Peixoto; Ana Luísa Santos; Susana Lopes; Regina Gonçalves; Pedro Pereira; Hélder Cardoso; Guilherme Macedo
Journal:  GE Port J Gastroenterol       Date:  2018-04-20

4.  New diagnostic technique to evaluate hepatic steatosis using the attenuation coefficient on ultrasound B mode.

Authors:  Yohei Koizumi; Masashi Hirooka; Nobuharu Tamaki; Norihisa Yada; Osamu Nakashima; Namiki Izumi; Masatoshi Kudo; Yoichi Hiasa
Journal:  PLoS One       Date:  2019-08-27       Impact factor: 3.240

5.  Performance of Controlled Attenuation Parameter in Patients with Advanced Chronic Liver Disease and Portal Hypertension.

Authors:  Georg Semmler; Judith Stift; Bernhard Scheiner; Katharina Wöran; Philipp Schwabl; Rafael Paternostro; Theresa Bucsics; Albert Friedrich Stättermayer; Matthias Pinter; Arnulf Ferlitsch; Michael Trauner; Thomas Reiberger; Mattias Mandorfer
Journal:  Dig Dis Sci       Date:  2019-06-17       Impact factor: 3.199

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.