Literature DB >> 29232026

Noncontrast-enhanced time-resolved 4D dynamic intracranial MR angiography at 7T: A feasibility study.

Fei Cong1,2, Yan Zhuo1, Songlin Yu3, Xianchang Zhang1,2, Xinyuan Miao1, Jing An4, Shuo Wang3, Yong Cao3, Yan Zhang3, Hee Kwon Song5, Danny Jj Wang6, Lirong Yan6.   

Abstract

BACKGROUND: Arterial spin labeling (ASL) based-noncontrast-enhanced 4D MR angiography (NCE 4D MRA) shows potential in characterizing cerebrovascular hemodynamics in cerebrovascular disorders. Ultrahigh-field theoretically benefits ASL signal with increased inherent signal-to-noise ratio (SNR) and prolonged blood T1 , which may provide improved delineation of vasculature in 4D MRA.
PURPOSE: To investigate the feasibility of NCE 4D MRA using 3D Cartesian trajectory and stack-of-stars (SOS) golden angle radial trajectory at 7T. STUDY TYPE: A prospective study.
SUBJECTS: Six normal volunteers and eight patients with arteriovenous malformation (AVM). FIELD STRENGTH/SEQUENCE: NCE 4D MRA with Cartesian and radial trajectories were performed at 3T and 7T. ASSESSMENT: Subjective image quality of 4D MRA was evaluated using a 4-point scale by two experienced neuroradiologists. The characterization of AVM components with 4D MRA and DSA was also graded using the Spetzler-Martin grading scale. STATISTICAL TESTS: Cohen's kappa coefficient was calculated to evaluate the agreement between two readers within each 4D MRA technique (Cartesian and Radial). A Wilcoxon signed-rank test was performed to compare the subjective image quality scores of 4D MRA between Cartesian and radial trajectories, and between 7T and 3T, respectively.
RESULTS: Good-to-excellent image quality was achieved in 4D MRA with both Cartesian (3.83 ± 0.41) and radial (3.42 ± 0.49) acquisitions in healthy volunteers at 7T. However, markedly reduced scan time was needed with radial acquisition. 4D MRA at 7T (3.31 ± 0.59) shows better delineation of AVM lesion features, especially the vein drainage, compared with that of 3T (2.83 ± 0.75), although no statistical significance was achieved (P = 0.180). DATA
CONCLUSION: The feasibility of ASL based 4D MRA at 7T with Cartesian and SOS golden angle radial acquisition was demonstrated. The clinical evaluation of 4D MRA in AVMs between 3T and 7T suggested 7T 4D MRA images acquired with radial acquisition demonstrate excellent delineation of AVM features, especially the draining veins. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage 2 J. Magn. Reson. Imaging 2017.
© 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  4-dimensional MRA; 7T; KWIC; arterial spin labeling; arteriovenous malformation; golden-angle radial

Mesh:

Substances:

Year:  2017        PMID: 29232026     DOI: 10.1002/jmri.25923

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  7 in total

1.  Validation of Zero TE-MRA in the Characterization of Cerebrovascular Diseases: A Feasibility Study.

Authors:  S Shang; J Ye; W Dou; X Luo; J Qu; Q Zhu; H Zhang; J Wu
Journal:  AJNR Am J Neuroradiol       Date:  2019-09       Impact factor: 3.825

2.  Acceleration of pCASL-Based Cerebral 4D MR Angiography Using Compressed SENSE: A Comparison With SENSE.

Authors:  Maoxue Wang; Yiming Ma; Fei Chen; Fei Zhou; Jilei Zhang; Bing Zhang
Journal:  Front Neurol       Date:  2022-03-21       Impact factor: 4.003

Review 3.  High-Resolution Neurovascular Imaging at 7T: Arterial Spin Labeling Perfusion, 4-Dimensional MR Angiography, and Black Blood MR Imaging.

Authors:  Xingfeng Shao; Lirong Yan; Samantha J Ma; Kai Wang; Danny J J Wang
Journal:  Magn Reson Imaging Clin N Am       Date:  2020-11-02       Impact factor: 1.376

Review 4.  A Systematic Review Comparing Digital Subtraction Angiogram With Magnetic Resonance Angiogram Studies in Demonstrating the Angioarchitecture of Cerebral Arteriovenous Malformations.

Authors:  Aishwarya Raman; Manish Uprety; Maria Jose Calero; Maria Resah B Villanueva; Narges Joshaghani; Nicole Villa; Omar Badla; Raman Goit; Samia E Saddik; Sarah N Dawood; Ahmad M Rabih; Ahmad Mohammed; Tharun Yadhav Selvamani; Jihan Mostafa
Journal:  Cureus       Date:  2022-06-09

5.  A rapid micro-magnetic resonance imaging scanning for three-dimensional reconstruction of peripheral nerve fascicles.

Authors:  Zhi Yao; Li-Wei Yan; Tao Wang; Shuai Qiu; Tao Lin; Fu-Lin He; Ru-Heng Yuan; Xiao-Lin Liu; Jian Qi; Qing-Tang Zhu
Journal:  Neural Regen Res       Date:  2018-11       Impact factor: 5.135

6.  The advantages of radial trajectories for vessel-selective dynamic angiography with arterial spin labeling.

Authors:  Eleanor S K Berry; Peter Jezzard; Thomas W Okell
Journal:  MAGMA       Date:  2019-08-17       Impact factor: 2.310

7.  Application Value of Contrast-Enhanced Ultrasound Combined with Enhanced MR Scanning in Patients with Intrahepatic Cholangiocarcinoma.

Authors:  Mingming Zhang; Yan Liu; Lei Han; Guixiang Zhang
Journal:  J Healthc Eng       Date:  2022-03-31       Impact factor: 2.682

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.