Literature DB >> 29224048

Comparison between whole-body and head and neck neurovascular coils for 3-T magnetic resonance proton resonance frequency shift thermography guidance in the head and neck region.

Daniel Thomas Ginat1, Gregory J Anthony2, Gregory Christoforidis2, Aytekin Oto2, Leonard Dalag2, Steffen Sammet2.   

Abstract

The purpose of this study is to compare the image quality of magnetic resonance (MR) treatment planning images and proton resonance frequency (PRF) shift thermography images and inform coil selection for MR-guided laser ablation of tumors in the head and neck region. Laser ablation was performed on an agar phantom and monitored via MR PRF shift thermography on a 3-T scanner, following acquisition of T1-weighted (T1W) planning images. PRF shift thermography images and T2-weighted (T2W) planning images were also performed in the neck region of five normal human volunteers. Signal-to-noise ratios (SNR) and temperature uncertainty were calculated and compared between scans acquired with the quadrature mode body integrated coil and a head and neck neurovascular coil. T1W planning images of the agar phantom produced SNRs of 4.0 and 12.2 for the quadrature mode body integrated coil and head and neck neurovascular coil, respectively. The SNR of the phantom MR thermography magnitude images obtained using the quadrature mode body integrated coil was 14.4 versus 59.6 using the head and neck coil. The average temperature uncertainty for MR thermography performed on the phantom with the quadrature mode body integrated coil was 1.1 versus 0.3 °C with the head and neck coil. T2W planning images of the neck in five human volunteers produced SNRs of 28.3 and 91.0 for the quadrature mode body integrated coil and head and neck coil, respectively. MR thermography magnitude images of the neck in the volunteers obtained using the quadrature mode body integrated coil had a signal-to-noise ratio of 8.3, while the SNR using the head and neck coil was 16.1. The average temperature uncertainty for MR thermography performed on the volunteers with the body coil was 2.5 versus 1.6 °C with the head and neck neurovascular coil. The quadrature mode body integrated coil provides inferior image quality for both basic treatment planning sequences and MR PRF shift thermography compared with a neurovascular coil, but may nevertheless be adequate for clinical purposes.

Entities:  

Keywords:  Head and neck; MRI proton resonance frequency shift thermography; Phantom; Quadrature body integrated coil; Signal-to-noise ratio; Thermal ablation

Mesh:

Substances:

Year:  2017        PMID: 29224048     DOI: 10.1007/s10103-017-2397-1

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  21 in total

1.  Temperature Measurement Using Echo-Shifted FLASH at Low Field for Interventional MRI.

Authors: 
Journal:  J Magn Reson Imaging       Date:  1999-07       Impact factor: 4.813

Review 2.  Magnetic resonance temperature imaging for guidance of thermotherapy.

Authors:  B Quesson; J A de Zwart; C T Moonen
Journal:  J Magn Reson Imaging       Date:  2000-10       Impact factor: 4.813

3.  MR-guided ablation of head and neck tumors.

Authors:  Martin G Mack; Thomas J Vogl
Journal:  Neuroimaging Clin N Am       Date:  2004-11       Impact factor: 2.264

4.  Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters.

Authors:  Olaf Dietrich; José G Raya; Scott B Reeder; Maximilian F Reiser; Stefan O Schoenberg
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

Review 5.  MR thermometry.

Authors:  Viola Rieke; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

6.  Laser thermal therapy: real-time MRI-guided and computer-controlled procedures for metastatic brain tumors.

Authors:  Alexandre Carpentier; Roger J McNichols; R Jason Stafford; Jean-Pierre Guichard; Daniel Reizine; Suzette Delaloge; Eric Vicaut; Didier Payen; Ashok Gowda; Bernard George
Journal:  Lasers Surg Med       Date:  2011-11-22       Impact factor: 4.025

7.  Ultrasound-guided percutaneous laser ablation in treating symptomatic solid benign thyroid nodules: Our experience in 45 patients.

Authors:  Gaetano Achille; Stefania Zizzi; Enrico Di Stasio; Alberto Grammatica; Luciano Grammatica
Journal:  Head Neck       Date:  2015-06-24       Impact factor: 3.147

8.  Laser-induced thermal therapy and cisplatin for recurrent head and neck cancer: a case characterized by an unusually long disease-free survival.

Authors:  Jayne Joo; Joel A Sercarz; Ana Amélia Paolini; Dan J Castro; Marcos B Paiva
Journal:  Ear Nose Throat J       Date:  2009-11       Impact factor: 1.697

9.  Real-time magnetic resonance-guided laser thermal therapy for focal metastatic brain tumors.

Authors:  Alexandre Carpentier; Roger J McNichols; R Jason Stafford; Julian Itzcovitz; Jean-Pierre Guichard; Daniel Reizine; Suzette Delaloge; Eric Vicaut; Didier Payen; Ashok Gowda; Bernard George
Journal:  Neurosurgery       Date:  2008-07       Impact factor: 4.654

10.  Quality of MR thermometry during palliative MR-guided high-intensity focused ultrasound (MR-HIFU) treatment of bone metastases.

Authors:  Mie K Lam; Merel Huisman; Robbert J Nijenhuis; Maurice Aaj van den Bosch; Max A Viergever; Chrit Tw Moonen; Lambertus W Bartels
Journal:  J Ther Ultrasound       Date:  2015-03-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.