Simulation studies of dual-energy x-ray absorptiometry.

J A Sorenson1, P R Duke, S W Smith.   

Abstract

Computer simulations were performed to predict the performance characteristics of dual-energy x-ray absorptiometry. K-edge filter techniques were analyzed in detail and compared to 153Gd sources in terms of output intensity, precision, patient dose, image contrast, beam hardening, and marrow fat effects. Similar analyses were performed for two dual-kV techniques that have been reported in the literature. The simulations indicate that K-edge filter techniques, or a dual-kV technique combined with K-edge filtering, can provide performance capabilities that equal or exceed those achievable with 153Gd systems. A (70/140) dual-kV technique with conventional (Al or Cu) filtration also has advantages in terms of source output intensity, but is 2-3 X inferior to the K-edge techniques and 153Gd in terms of patient dose and beam-hardening effects.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2921984     DOI: 10.1118/1.596405

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Measurements of bone mineral density of the proximal femur by two commercially available dual energy X-ray absorptiometric systems.

Authors:  O L Svendsen; U Marslew; C Hassager; C Christiansen
Journal:  Eur J Nucl Med       Date:  1992

2.  Modulator design for x-ray scatter correction using primary modulation: material selection.

Authors:  Hewei Gao; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

3.  A comparison of two dual-energy X-ray absorptiometry systems for spinal bone mineral measurement.

Authors:  K C Lai; M M Goodsitt; R Murano; C H Chesnut
Journal:  Calcif Tissue Int       Date:  1992-03       Impact factor: 4.333

4.  The accuracy of volumetric bone density measurements in dual x-ray absorptiometry.

Authors:  M A Sabin; G M Blake; S M MacLaughlin-Black; I Fogelman
Journal:  Calcif Tissue Int       Date:  1995-03       Impact factor: 4.333

5.  Recent advances in bone densitometry.

Authors:  G M Blake; I Fogelman
Journal:  Eur J Nucl Med       Date:  1993-09

6.  Long-term experiment to study the development, interaction, and influencing factors of DEXA parameters.

Authors:  Helmut Fuchs; Christine Gau; Wolfgang Hans; Valerie Gailus-Durner; Martin Hrabě de Angelis
Journal:  Mamm Genome       Date:  2013-10-06       Impact factor: 2.957

Review 7.  Bone density measurements.

Authors:  E M Alhava
Journal:  Calcif Tissue Int       Date:  1991       Impact factor: 4.333

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.