Literature DB >> 29201153

Poor glycaemic control is associated with reduced exercise performance and oxygen economy during cardio-pulmonary exercise testing in people with type 1 diabetes.

Othmar Moser1,2, Max L Eckstein1,2, Olivia McCarthy1,2, Rachel Deere1,2, Stephen C Bain1, Hanne L Haahr3, Eric Zijlstra4, Richard M Bracken1,2.   

Abstract

BACKGROUND: To explore the impact of glycaemic control (HbA1c) on functional capacity during cardio-pulmonary exercise testing in people with type 1 diabetes.
METHODS: Sixty-four individuals with type 1 diabetes (age: 34 ± 8 years; 13 females, HbA1c: 7.8 ± 1% (62 ± 13 mmol/mol), duration of diabetes: 17 ± 9 years) performed a cardio-pulmonary cycle ergometer exercise test until volitional exhaustion. Stepwise linear regression was used to explore relationships between HbA1c and cardio-respiratory data with p ≤ 0.05. Furthermore, participants were divided into quartiles based on HbA1c levels and cardio-respiratory data were analysed by one-way ANOVA. Multiple regression analysis was performed to explore the relationships between changes in time to exhaustion and cardio-respiratory data. Data were adjusted for confounder.
RESULTS: HbA1c was related to time to exhaustion and oxygen consumption at the power output elicited at the sub-maximal threshold of the heart rate turn point (r = 0.47, R2 = 0.22, p = 0.03). Significant differences were found at time to exhaustion between QI vs. QIV and at oxygen consumption at the power output elicited at the heart rate turn point between QI vs. QII and QI vs. QIV (p < 0.05). Changes in oxygen uptake, power output and in oxygen consumption at the power output elicited at the heart rate turn point and at maximum power output explained 55% of the variance in time to exhaustion (r = 0.74, R2 = 0.55, p < 0.01).
CONCLUSIONS: Poor glycaemic control is related to less economical use of oxygen at sub-maximal work rates and an earlier time to exhaustion during cardio-pulmonary exercise testing. However, exercise training could have the same potential to counteract the influence of poor glycaemic control on functional capacity. Trial registration NCT01704417. Date of registration: October 11, 2012.

Entities:  

Keywords:  Exercise performance; Glycaemic control; Heart rate turn point; Oxygen economy; Type 1 diabetes

Year:  2017        PMID: 29201153      PMCID: PMC5697085          DOI: 10.1186/s13098-017-0294-1

Source DB:  PubMed          Journal:  Diabetol Metab Syndr        ISSN: 1758-5996            Impact factor:   3.320


Introduction

Type 1 diabetes (T1D) is associated with an increased risk of cardio-vascular disease (CVD) compared to people without diabetes. Although regular physical activity is encouraged as a cornerstone of good diabetes management [1, 2], physical inactivity rates remain high [3]. Patients often cite low functional capacity and loss of metabolic control (short-term and/or long term glycaemic disturbances) as barriers to beginning or maintaining regular physical activity [4]. Functional capacity, defined as the ability to perform aerobic work during maximal exercise testing can be assessed by means of cardio-pulmonary exercise (CPX) testing. This non-invasive, sensitive test provides an assessment of integrative responses of cardiovascular, pulmonary and musculoskeletal systems across a sub-maximal to maximal continuum and can be utilised to identify fatigue of cardiovascular or respiratory origin [5]. Most reported studies in people with T1D have assessed maximum cardio-pulmonary values such as the peak oxygen uptake (VO2peak) [6-8]. VO2peak is the highest rate of oxygen that can be consumed during exercise involving the majority of muscle mass at sea-level and is defined by the Fick equation as the product of cardiac output and arteriovenous oxygen difference [5]. Achieving a true VO2peak requires strong motivation and physical fitness, but for people with T1D with ‘low exercise tolerance’ the perception of exercise-induced pain may encourage premature test termination. In addition, the presence of diabetes complications such as neuropathy, nephropathy and underlying CVD may exacerbate pain or damage during exercise and reduce the validity of CPX testing in detailing accurate maximum cardio-respiratory parameters e.g. VO2 plateau, maximum heart rate (HRmax). Most activities in daily life are performed at low-to moderate intensity and do not require maximum cardio-respiratory effort. It may be more relevant in people with T1D to explore cardio-respiratory data obtained during sub-maximal stages of CPX testing. The rate of oxygen use at sub-maximal exercise intensities provides an indication of the economy of use of oxygen for an individual to the work rate and has been shown to predict endurance performance in healthy individuals [9]. Furthermore, identification of the sub-maximal work rate at which there is an increase in use of non-oxidative fuel sources (i.e. cellular glycolysis) results in a greater production of carbon dioxide (CO2), pyruvate and lactic acid fermentation. Identification of such ‘thresholds’ involving ventilation, heart rate and/or blood lactate have been studied as sub-maximal predictors of endurance capacity in healthy cohorts and in people with chronic disease [5]. As an example the heart rate turn point (HRTP), which is based on findings from Conconi et al., was significantly associated with the second lactate threshold [10-13]. This heart rate derived threshold is defined as the intersection of two regression lines of the heart rate to performance curve between early stages of CPX testing [peri-first lactate turn point (LTP1)] and maximum power output (Pmax), determined from a second-degree polynomial representation satisfying the condition of least error squares [14]. However, there is a lack of information about their use in people with T1D in predicting functional capacity. Lower maximum cardio-respiratory variables have been reported in participants with T1D compared to healthy individuals in some studies but not in others [8, 15]. A review by Baldi et al. [16] shed some light on the influence of glycaemic control within people with T1D and when compared to healthy individuals. Patients with poor glycaemic control demonstrated a lower peak functional capacity than those patients with good glycaemic control. No information currently exists on the influence of glycaemic control on sub-maximal cardio-respiratory parameters obtained from a CPX test. Such information might reveal additional insights on the impact of glycaemia on the functioning of the cardio-vascular and respiratory system and provide further support for the use of moderate intensity exercise tests that reduce stress on the patient. The aim of this study was to examine the relationship of glycaemic control to sub-maximal and maximum cardio-pulmonary markers obtained during CPX testing in people with T1D.

Materials and methods

Participant characteristics

Adults (aged 18–45 years, both inclusive) with T1D eligible for the study had a body mass index (BMI) of 18–27 kg/m2, glycated haemoglobin (HbA1c) level ≤ 9.5% (80 mmol/mol) and were performing regular physical cardiorespiratory exercise during the last 3 months before screening. Exclusion criteria included cancer, cardiac diseases, supine blood pressure outside the range 90–140 mmHg for systolic blood pressure or 50–90 mmHg for diastolic blood pressure, recurrent severe hyperglycaemia or hypoglycaemia unawareness and smoking [17]. Sixty-four people with T1D were included for analyses (Table 1). Data were extracted from a clinical trial (NCT01704417) [17].
Table 1

Participant characteristics given as mean ± SD and percentage (%)

CharacteristicTotal (n = 64)
Age (years)34 ± 8
Gender
 Female (n; %)13 (20)
 Male (n; %)51 (80)
Body mass index (kg/m2)24 ± 2
Blood pressure (mmHg)124 ± 17/79 ± 12
Resting heart rate (b/min)81 ± 12
Duration of diabetes (years)17 ± 9
HbA1c [% (mmol/mol)]7.8 ± 1 (62 ± 13)
Total daily dose of insulin (U)51 ± 15
Type of therapy
 Multiple daily injections (n; %)47 (78)
 Insulin pump therapy (n; %)17 (22)
Co-morbidities14
 Arterial hypertension6
 Hypothyroidism5
 Hypercholesterolemia2
 Hashimoto thyroiditis1
Medication other than insulin
 ACE inhibitor6
 Levothyroxine6
 Statin2
 Diuretic medication1
 Calcium channel blocker1
Physical activity assessed via IPAQ (MET min week)3086 ± 2736
Participant characteristics given as mean ± SD and percentage (%)

Study procedures

After the assessment of eligibility, patients were asked to fill in the International Physical Activity Questionnaire (IPAQ) to assess physical activity (MET min/week). Patients characteristics, medical history and medications were documented in a case report form (CRF). Afterwards, HbA1c was measured via a venous blood sample collected from the antecubital vein (Automated Glycohemoglobin Analyzer HLC-723G8, Tosoh Europe N.V, Belgium). Immediately before and after CPX testing, venous blood was collected to analyse blood glucose concentration to ensure euglycaemia during CPX testing (Super GL Glucose Analyzer, Dr. Müller Gerätebau GmbH, Germany). If pre-exercise venous blood glucose concentration was below 4.4 mmol/l carbohydrates were given (15–30 g) and if blood glucose concentration was above 13.9 mmol/l a small bolus correction dose was administered. No hypo- (< 3.9 mmol/l) or severe hyperglycaemia (> 19.4 mmol/l) occurred before or during CPX testing. The timing of bolus insulin injection was not exactly pre-defined, but participants were told to avoid the peak action of bolus insulin during CPX testing (this means avoiding bolus insulin injections less than 120 min prior to the start of CPX testing). Participants performed a CPX test until volitional exhaustion on a cycle ergometer (Ergospirometer PowerCube®-Ergo, Ganshorn Medizin Electronic, GER). Participants sat quietly on the cycle ergometer for 3 min (0 W) before they started the warm-up period of 3 min cycling at a workload of 30 W for females and 40 W for males. Then, the workload was increased by 30 W for females and 40 W for males every 3 min until maximum volitional exhaustion. Finally, a cool-down period was performed for 1 min.

Measurements

Pulmonary gas exchange variables were collected continuously by breath-by-breath measurement and then averaged over 10 s. VO2peak was defined as the 1 min average in oxygen (O2) consumption during the highest work rate. Heart rate and blood pressure were measured continuously via a 12-lead electrocardiogram and an automatic sphygmomanometer (Ergospirometer PowerCube®-Ergo, Ganshorn Medizin Electronic, GER). The non-invasive anaerobic threshold was defined by the HRTP [18]. HRTP was demarcated as the intersection of two regression lines of the heart rate to performance curve between post-warm-up and maximum power output (Pmax), determined from the second-degree polynomial representation satisfying the condition of least error squares [14]. Additionally, the second ventilatory threshold (VT2) was determined by means of the ventilation/carbon dioxide (VE/VCO2) slope [19] to control for the accuracy of HRTP.

Statistical analysis

Data (10 s average) were expressed as absolute values and relative to maximum physiological variables and Pmax. Data were tested for distribution via Shapiro-Wilks normality test and non-normal distributed data were log transformed. Stepwise linear regression was used to explore relationships between glycaemic control (HbA1c) and CPX obtained cardio-respiratory data and performance markers with p ≤ 0.05. Data were adjusted for sex, age, BMI, blood glucose concentration at the start of CPX testing and duration of diabetes. Post hoc power analysis for the primary outcome [stepwise linear regression: dependent variable HbA1c levels, independent variables time to exhaustion (Timemax) and oxygen economy at HRTP] resulted in a power (1-beta error probability) of 0.96. Participants were divided into quartiles (Q) based on HbA1c levels, and respective sub-maximal and maximal CPX derived cardio-respiratory data and performance markers were analysed by one-way analysis of variance (ANOVA) followed by a fishers least significant difference multiple comparison post hoc test (LSD). Multiple regression analysis was performed to explore relationships between changes in Timemax and independent variables, VO2peak and oxygen uptake at the heart rate turn point (VO2HRTP), body mass adjusted values of Pmax and power output at the heart rate turn point (PHRTP) as well as oxygen economy at Pmax [VO2peak/Pmax (ml/min/W)] and at HRTP [VO2HRTP/PHRTP (ml/min/W)]. All statistics were performed with a standard software package of SPSS software version 22 (IBM Corporation, USA) and Prism Software version 7.0 (GraphPad, USA).

Results

Exercise performance data

Maximum physiological parameters were found at HRmax of 185 ± 11 b/min, VO2peak 37 ± 5 ml/kg/min, respiratory exchange ratio (RER) 1.22 ± 0.09 and Pmax 231 ± 47 W. No significant differences were found between the HRTP and the VT2 as well as for the comparison of pre- and post-exercise blood glucose concentration as given in Table 2.
Table 2

Comparison of the anaerobic thresholds derived from HRTP and VT2 as well as pre- and post-exercise blood glucose levels

HRTPVT2 p value
VO2 (l/min)2.09 ± 0.502.17 ± 0.500.41
HR (b/min)158 ± 14157 ± 170.63
P (W)169 ± 39172 ± 380.45
VE (l/min)55 ± 1358 ± 140.26

Results are given as mean ± SD

Comparison of the anaerobic thresholds derived from HRTP and VT2 as well as pre- and post-exercise blood glucose levels Results are given as mean ± SD

Glycaemic control and functional capacity

As shown in Fig. 1, sex-, age-, BMI-, blood glucose concentration at the start of CPX testing- and duration of diabetes-adjusted stepwise linear regression model revealed that HbA1c was related to Timemax and oxygen consumption at the power output elicited at the sub-maximal threshold of the heart rate turn point (VO2HRTP/PHRTP) (r = 0.47, R2 = 0.22, p = 0.03).
Fig. 1

Relationships between HbA1c and a Timemax and b VO2HRTP/PHRTP, n = 64

Relationships between HbA1c and a Timemax and b VO2HRTP/PHRTP, n = 64

Grouped HbA1c levels and functional capacity

Grouping participants based on quartiles of glycaemic control resulted in HbA1c levels of 6.7 ± 0.5% (49 ± 6 mmol/mol) for quartile I, 7.6 ± 0.1% (60 ± 1 mmol/mol) for quartile II, 8.0 ± 0.1% (63 ± 1 mmol/mol) for quartile III and 9.1 ± 0.6% (76 ± 7 mmol/mol) for quartile IV (p < 0.01). No significant differences were found for physical activity (p = 0.68), resting HR (p = 0.42), systolic blood pressure (p = 0.18) and diastolic blood pressure (p = 0.83) between groups. Significant differences were found at Timemax between QI vs. QIV (mean difference 2.5 ± 1.0 min, p = 0.02) and at VO2HRTP/PHRTP between QI vs. QII (− 1.5 ± 0.6 ml/min/W, p = 0.02) and QI vs QIV (− 1.6 ± 0.71 ml/min/W, p = 0.01) (Fig. 2).
Fig. 2

HbA1c quartiles for a Timemax and b VO2HRTP/PHRTP

HbA1c quartiles for a Timemax and b VO2HRTP/PHRTP White bar = QI (HbA1c 6. ± 0.5%; 4 ± 6 mmol/mol), bright-grey bar = QII (HbA1c 7. ± 0.1%; 60 ± 1 mmol/mol), dark-grey bar = QIII (HbA1c 8. ± 0.1%; 6 ± 1 mmol/mol) and black bar = QIV (HbA1c 9.1 ± 0.6%; 7 ± 7 mmol/mol). Values are given as mean and SD. “*” represents p ≤ 0.05.

Relationships of time to exhaustion and cardio-pulmonary responses during CPX testing

Multiple regression analysis revealed that changes in VO2peak, VO2HRTP, Pmax, PHRTP, VO2 /PHRTP as well as VO2peak/Pmax constitute independent predictors of Timemax (r = 0.74, p < 0.01) and those variables could explain 55% of the alteration in Timemax.

Discussion

This study demonstrated an important relationship between glycaemic control and the cardio-respiratory responses to CPX testing in people with T1D. Exercise economy is defined as the rate of oxygen use at a given workload. We found that individuals with poorer glycaemic control (higher HbA1c values) displayed a higher rate of O2 use at a sub-maximal work rate (HRTP) and earlier Timemax. This result is confirmed by the findings from Tagougui et al. in which the increase in deoxyhemoglobin (reflection of relative tissue deoxygenation) in the vastus lateralis was blunted in patients with T1D and with poor glycaemic control during CPX testing [20]. Interestingly, the maximum oxygen consumption was negatively correlated with changes in deoxyhemoglobin. Our findings are in contrast to recent studies evaluating the association between glycaemic control and functional capacity [6, 8]. Stubbe et al. could not find an association between HbA1c levels and the O2 uptake at the anaerobic lactate threshold [8]. This contrast in comparison to our results might explained by lower and more homogeneous HbA1c levels as observed in our cohort. The variation in glycaemic control and its upper and lower extremes clearly contributed to the association between HbA1c levels and rates of O2 use at the HRTP. Turinese et al. also did not find significant relationships between the glycaemic control and CPX derived markers [6]. However, the lack of associations might be originated by the low number of participants (N = 17). There may be several postulated reasons for our findings. During exercise, skeletal muscle consumes most of the inhaled O2 and a greater O2 cost for a given exercise intensity might indicate fibre atrophy and/or morphological abnormalities in the mitochondria [21]. Reduced skeletal muscle mitochondrial ATP production rates have also been associated with poor glycaemic control [22]. Furthermore, the capillary density surrounding skeletal muscle has been shown to be lower in individuals with T1D [23]. A reduced oxidative capacity within prime mover muscles increases dependence on supporting muscles, and increases the overall oxygen cost of the activity for a given workload. Furthermore, an earlier limit on O2 use within a muscle shifts energy metabolism towards non-oxidative glycolysis and an earlier lowered pH [24]. Alternatively, oxygen supply systems may be compromised more in individuals with poorer glycaemic control. Red blood cell dynamics have been shown to be altered in T1D rats [25] with velocity and flux reduced in comparison to non-diabetics, albeit with a similar haematocrit. People with T1D may display cardiomyopathy and this seems dependent on the HbA1c value which has been hypothesised to alter cardiac structure, e.g. increased left ventricular wall thickness and mass, and impaired diastolic function. Interestingly, poor glycaemic control was associated with reduced stroke volume and cardiac output in athletes with T1D compared with non-diabetic individuals, despite an equivalent amount of training [26]. This reduction in stroke volume might be caused by earlier diastolic dysfunction, which reduces the atrioventricular pressure gradient and causes early diastolic left ventricular filling [16]. The decreased economy at early stages during CPX testing translated to shorter exercise test duration. Indeed, approximately 55% of the shorter total exercise time could be accounted for lowered O2 uptake, decreased power output and less economical use of O2 for both at the HRTP and maximum power. Taken this into account, it might be that regular exercise training, which increases these physiological parameters, might have similar potential to neutralise the negative influence of glycaemic control on functional capacity [27] and even on cardiovascular autonomic regulation [28]. This study is limited by the heterogeneity and the wide range in the duration of diabetes, age, blood glucose concentration at the start of CPX testing and sex distribution. However, we addressed this limitation as we have adjusted for these factors. Additionally, it might be that different levels of blood glucose influenced catecholamine response which in turn altered cardiac function during CPX testing.

Conclusions

In conclusion, in this well-characterised study, individuals with T1D and poorer glycaemic control displayed less economical use of oxygen at sub-maximal work rates and an earlier time to exhaustion during CPX testing. Nevertheless, exercise training could have the same potential to counteract the influence of poor glycaemic control on functional capacity.
  28 in total

Review 1.  Effects of type 1 diabetes mellitus on skeletal muscle: clinical observations and physiological mechanisms.

Authors:  Matthew P Krause; Michael C Riddell; Thomas J Hawke
Journal:  Pediatr Diabetes       Date:  2010-09-22       Impact factor: 4.866

Review 2.  Why should people with type 1 diabetes exercise regularly?

Authors:  Roberto Codella; Ileana Terruzzi; Livio Luzi
Journal:  Acta Diabetol       Date:  2017-03-14       Impact factor: 4.280

3.  Heart rate threshold related to lactate turn point and steady-state exercise on a cycle ergometer.

Authors:  P Hofmann; V Bunc; H Leitner; R Pokan; G Gaisl
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1994

4.  Heart rate break point may coincide with the anaerobic and not the aerobic threshold.

Authors:  J P Ribeiro; R A Fielding; V Hughes; A Black; M A Bochese; H G Knuttgen
Journal:  Int J Sports Med       Date:  1985-08       Impact factor: 3.118

Review 5.  Exercise management in type 1 diabetes: a consensus statement.

Authors:  Michael C Riddell; Ian W Gallen; Carmel E Smart; Craig E Taplin; Peter Adolfsson; Alistair N Lumb; Aaron Kowalski; Remi Rabasa-Lhoret; Rory J McCrimmon; Carin Hume; Francesca Annan; Paul A Fournier; Claudia Graham; Bruce Bode; Pietro Galassetti; Timothy W Jones; Iñigo San Millán; Tim Heise; Anne L Peters; Andreas Petz; Lori M Laffel
Journal:  Lancet Diabetes Endocrinol       Date:  2017-01-24       Impact factor: 32.069

6.  "Metabolic and cardiovascular response to exercise in patients with type 1 diabetes".

Authors:  I Turinese; P Marinelli; M Bonini; M Rossetti; G Statuto; T Filardi; A Paris; A Lenzi; S Morano; P Palange
Journal:  J Endocrinol Invest       Date:  2017-04-06       Impact factor: 4.256

7.  Exercise might improve cardiovascular autonomic regulation in adolescents with type 1 diabetes.

Authors:  Daniela Lucini; Gian Vincenzo Zuccotti; Andrea Scaramuzza; Mara Malacarne; Federico Gervasi; Massimo Pagani
Journal:  Acta Diabetol       Date:  2012-09-01       Impact factor: 4.280

8.  Diastolic function is reduced in adolescents with type 1 diabetes in response to exercise.

Authors:  Silmara Gusso; Teresa E Pinto; James C Baldi; Elizabeth Robinson; Wayne S Cutfield; Paul L Hofman
Journal:  Diabetes Care       Date:  2012-07-06       Impact factor: 19.112

9.  Barriers to physical activity among patients with type 1 diabetes.

Authors:  Anne-Sophie Brazeau; Rémi Rabasa-Lhoret; Irene Strychar; Hortensia Mircescu
Journal:  Diabetes Care       Date:  2008-08-08       Impact factor: 17.152

10.  Similar risk of exercise-related hypoglycaemia for insulin degludec to that for insulin glargine in patients with type 1 diabetes: a randomized cross-over trial.

Authors:  T Heise; S C Bain; R M Bracken; E Zijlstra; L Nosek; K Stender-Petersen; R Rabøl; E Rowe; H L Haahr
Journal:  Diabetes Obes Metab       Date:  2015-11-27       Impact factor: 6.577

View more
  5 in total

Review 1.  The Potential of Current Noninvasive Wearable Technology for the Monitoring of Physiological Signals in the Management of Type 1 Diabetes: Literature Survey.

Authors:  Elena Daskalaki; Anne Parkinson; Nicola Brew-Sam; Md Zakir Hossain; David O'Neal; Christopher J Nolan; Hanna Suominen
Journal:  J Med Internet Res       Date:  2022-04-08       Impact factor: 7.076

Review 2.  Exercise Testing in Individuals With Diabetes, Practical Considerations for Exercise Physiologists.

Authors:  Christophe Kosinski; Cyril Besson; Francesca Amati
Journal:  Front Physiol       Date:  2019-09-27       Impact factor: 4.566

3.  Pre-Exercise Blood Glucose Levels Determine the Amount of Orally Administered Carbohydrates during Physical Exercise in Individuals with Type 1 Diabetes-A Randomized Cross-Over Trial.

Authors:  Othmar Moser; Max L Eckstein; Alexander Mueller; Philipp Birnbaumer; Felix Aberer; Gerd Koehler; Caren Sourij; Harald Kojzar; Peter Pferschy; Pavel Dietz; Richard M Bracken; Peter Hofmann; Harald Sourij
Journal:  Nutrients       Date:  2019-06-06       Impact factor: 5.717

Review 4.  Resistance Isn't Futile: The Physiological Basis of the Health Effects of Resistance Exercise in Individuals With Type 1 Diabetes.

Authors:  Olivia McCarthy; Othmar Moser; Max L Eckstein; Rachel Deere; Steve C Bain; Jason Pitt; Richard M Bracken
Journal:  Front Endocrinol (Lausanne)       Date:  2019-08-02       Impact factor: 5.555

Review 5.  Cardiovascular and systemic determinants of exercise capacity in people with type 2 diabetes mellitus.

Authors:  Joanna M Bilak; Gaurav S Gulsin; Gerry P McCann
Journal:  Ther Adv Endocrinol Metab       Date:  2021-01-27       Impact factor: 3.565

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.