Literature DB >> 29195844

Leaflet thrombosis following transcatheter aortic valve implantation.

M Marwan1, N Mekkhala2, M Göller2, J Röther2, D Bittner3, A Schuhbaeck2, M Hell2, G Muschiol2, J Kolwelter2, R Feyrer4, C Schlundt2, S Achenbach2, M Arnold2.   

Abstract

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being offered to high-risk patients with symptomatic aortic valve stenosis. Recent reports have suggested a high incidence of subclinical leaflet thrombosis following bioprosthestic aortic valve replacement. We report the frequency and clinical presentation of leaflet thrombosis identified by cardiac CT in patients referred for follow-up contrast enhanced CT angiography following TAVI.
METHODS: 91 consecutive patients referred for follow-up contrast-enhanced CT angiography following TAVI were screened for inclusion in this analysis. Out of these, 13 patients were excluded. All CT examinations were performed using a 2nd or a 3rd generation dual-source system (Somatom Definition Flash/Force, Forchheim, Germany). In all patients, retrospectively ECG-gated spiral acquisition with tube modulation was performed to allow for assessment of leaflet motion. All prostheses were analyzed for presence of leaflet thrombosis defined as hypo-attenuated leaflet thickening with or without leaflet restriction. Post-procedural antithrombotic regimen as well as symptom status was documented in all patients.
RESULTS: 78 consecutive patients (35 males, 81 ± 4 years) were analyzed. TAVI had been performed in all patients (76 transfemoral access, 2 transapical access) with either balloon-expandable prostheses (4 Sapien XT, 64 Sapien 3) or self-expandable prostheses (5 SJM Portico, 5 Symetis Acurate). Follow-up CT angiography was performed at a median of 4 months following index procedure (Interquartile range 1 month). Leaflet thrombosis was detected in 18 patients (23%, 14 Sapien 3, 1 Sapien XT, 2 SJM Portico, 1 Symetis Acurate). In patients with leaflet thickening on CT, only 11% were on either oral anticoagulation or new oral anticoagulants versus 50% for patients with no leaflet thickening (p 0.002). In patients with leaflet thrombosis, 3 leaflets were affected in 5 patients, 2 leaflets in 5 patients and in 8 patient only 1 leaflet was affected. Clinical symptoms (angina, dyspnea or both) were reported in 2/18 patients with leaflet thrombosis (11%) and in both patients a significant increase of the mean echocardiographic gradient over the prosthesis was documented. The peak and mean echocardiographic gradients obtained at the day of CT examination was significantly higher in symptomatic patients versus asymptomatic patients (peak 46 ± 7 vs. 23 ± 11 mmHg, mean 29 ± 7 vs. 12 ± 6 mmHg, p = 0.01 and 0.002, respectively). Follow-up CT was available for 4 patients with complete resolution of the hypo-attenuated leaflet thickening following treatment.
CONCLUSION: Leaflet thrombosis following TAVI is a relatively frequent finding in patients referred for contrast enhanced CT angiography following TAVI. In the majority of patients it follows a subclinical course and is substantially more frequent in individuals who are not on oral anticoagulation. However, in patients with relevant increase in prosthetic gradients, symptomatic presentations are possible.
Copyright © 2018 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Computed tomography; Leaflet thrombosis; Transcatheter aortic valve replacement / implantation (TAVR / TAVI)

Mesh:

Substances:

Year:  2017        PMID: 29195844     DOI: 10.1016/j.jcct.2017.11.002

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  10 in total

Review 1.  The Use of Biological Heart Valves.

Authors:  Sami Kueri; Fabian A Kari; Rafael Ayala Fuentes; Hans-Hinrich Sievers; Friedhelm Beyersdorf; Wolfgang Bothe
Journal:  Dtsch Arztebl Int       Date:  2019-06-21       Impact factor: 5.594

Review 2.  How to Image and Manage Prosthesis-Related Complications After Transcatheter Aortic Valve Replacement.

Authors:  Nina C Wunderlich; Jörg Honold; Martin J Swaans; Robert J Siegel
Journal:  Curr Cardiol Rep       Date:  2021-07-01       Impact factor: 2.931

Review 3.  Principles of TAVR valve design, modelling, and testing.

Authors:  Oren M Rotman; Matteo Bianchi; Ram P Ghosh; Brandon Kovarovic; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2018-10-29       Impact factor: 3.166

4.  Leaflet thrombosis after valve-in-valve transcatheter aortic valve implantation: a case series.

Authors:  Dincer Aktuerk; Saeed Mirsadraee; Cesare Quarto; Simon Davies; Alison Duncan
Journal:  Eur Heart J Case Rep       Date:  2020-09-16

Review 5.  Transcatheter Aortic Valve Leaflet Thrombosis: Prevalence, Management, and Future Directions.

Authors:  Makoto Nakashima; Hasan Jilaihawi
Journal:  Curr Cardiol Rep       Date:  2021-11-11       Impact factor: 2.931

6.  In Vitro Durability and Stability Testing of a Novel Polymeric Transcatheter Aortic Valve.

Authors:  Oren M Rotman; Brandon Kovarovic; Matteo Bianchi; Marvin J Slepian; Danny Bluestein
Journal:  ASAIO J       Date:  2020-02       Impact factor: 3.826

7.  A Novel Sensorized Heart Valve Prosthesis: Preliminary In Vitro Evaluation.

Authors:  Emanuela Marcelli; Barbara Bortolani; Ivan Corazza; Laura Cercenelli
Journal:  Sensors (Basel)       Date:  2018-11-13       Impact factor: 3.576

8.  Cusp thrombosis of a self-expandable sutureless aortic valve treated by valve-in-valve transcatheter aortic valve implantation procedure: case report.

Authors:  Ulvi Cenk Oezpeker; Gudrun Feuchtner; Nikolaos Bonaros
Journal:  Eur Heart J Case Rep       Date:  2018-12-07

9.  Impact of leaflet thrombosis on hemodynamics and clinical outcomes after bioprosthetic aortic valve replacement: A meta-analysis.

Authors:  Zixin Tian; Tiejun Li; Shumei Ma
Journal:  Clin Cardiol       Date:  2020-01-20       Impact factor: 2.882

Review 10.  Clinical Valve Thrombosis and Subclinical Leaflet Thrombosis Following Transcatheter Aortic Valve Replacement: Is There a Need for a Patient-Tailored Antithrombotic Therapy?

Authors:  Liesbeth Rosseel; Ole De Backer; Lars Søndergaard
Journal:  Front Cardiovasc Med       Date:  2019-04-18
  10 in total