Literature DB >> 2919563

Efficacy of intraoperative transesophageal echocardiography in children with congenital heart disease.

S E Cyran1, T R Kimball, R A Meyer, W W Bailey, E Lowe, W F Balisteri, S Kaplan.   

Abstract

The feasibility and potential adverse effects of using intraoperative transesophageal echocardiography (TEE) in 19 children ages 7.5 to 16 years undergoing surgical repair of a variety of congenital heart defects were evaluated. The ability of TEE to assess the adequacy of surgical repair as well as left ventricular function and wall motion abnormalities in this setting was also examined. Intraoperative transesophageal 2-dimensional and Doppler evaluation, and, in selected patients, echo-contrast and color flow imaging, were performed with either a 3.5- or 5.0-MHz phased array probe mounted within the tip of a flexible gastroscope. Probe insertion was successful in 18 of 19 patients. Fiberoptic endoscopy (9 patients) and autopsy (1 patient--cardiac donor) performed within 24 hours of surgery demonstrated no significant esophageal abnormalities. Intraoperative wall motion abnormalities were identified in 8 patients but did not persist after the operation. An adequate surgical repair was demonstrated by contrast and color flow imaging in most patients. Microcavitation was detected in 6 patients for greater than 5 minutes after a standard debubbling procedure. No patient displayed any adverse neurologic effects. It is concluded that, with the currently available probes, intraoperative TEE can be performed safely and reliably in children as young as 7.5 years of age. The procedure provides valuable information regarding wall motion abnormalities, cardiac function and the adequacy of surgical repair.

Entities:  

Mesh:

Year:  1989        PMID: 2919563     DOI: 10.1016/0002-9149(89)90905-3

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

1.  Intraoperative transesophageal echocardiography for congenital heart disease.

Authors:  T F Feltes
Journal:  Tex Heart Inst J       Date:  1992

2.  First in vivo use of a capacitive micromachined ultrasound transducer array-based imaging and ablation catheter.

Authors:  Douglas N Stephens; Uyen T Truong; Amin Nikoozadeh; Omer Oralkan; Chi Hyung Seo; Jonathan Cannata; Aaron Dentinger; Kai Thomenius; Alan de la Rama; Tho Nguyen; Feng Lin; Pierre Khuri-Yakub; Aman Mahajan; Kalyanam Shivkumar; Matt O'Donnell; David J Sahn
Journal:  J Ultrasound Med       Date:  2012-02       Impact factor: 2.153

3.  Intraoperative transesophageal echocardiography in congenital heart surgery. The Texas Children's Hospital experience.

Authors:  L I Bezold; R Pignatelli; C A Altman; T F Feltes; R J Gajarski; G W Vick; N A Ayres
Journal:  Tex Heart Inst J       Date:  1996

4.  Assessment of anomalous systemic and pulmonary venous connections by transoesophageal echocardiography in infants and children.

Authors:  O Stümper; J Vargas-Barron; M Rijlaarsdam; A Romero; J R Roelandt; J Hess; G R Sutherland
Journal:  Br Heart J       Date:  1991-12

5.  Transoesophageal echocardiography in neonates, infants and children: applicability and diagnostic value in everyday practice of a cardiothoracic unit.

Authors:  P J Scott; M E Blackburn; G A Wharton; N Wilson; D F Dickinson; J L Gibbs
Journal:  Br Heart J       Date:  1992-11

6.  Accuracy of Intraoperative Epicardial Echocardiography in the Assessment of Surgical Repair of Congenital Heart Defects confirmed.

Authors:  Veeresh F Manvi; Mahadev Dixit; Kini Srinivas; Anand Vagarali; Sharan Patil; Nidhi Goel Manvi
Journal:  J Cardiovasc Echogr       Date:  2013 Apr-Jun

7.  Prospective evaluation of complications associated with transesophageal echocardiography in dogs with congenital heart disease.

Authors:  Caitlin H Stoner; Ashley B Saunders; Johanna C Heseltine; Audrey K Cook; Jonathan A Lidbury
Journal:  J Vet Intern Med       Date:  2022-01-08       Impact factor: 3.333

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.