Literature DB >> 29192887

A Feasibility Study of Low-Dose Single-Scan Dual-Energy Cone-Beam CT in Many-View Under-Sampling Framework.

Donghyeon Lee, Jiseoc Lee, Hyoyi Kim, Taewon Lee, Jeongtae Soh, Miran Park, Changhwan Kim, Yeon Ju Lee, Seungryong Cho.   

Abstract

A single-scan dual-energy low-dose cone-beam CT (CBCT) imaging technique that exploits a multi-slit filter is proposed in this paper. The multi-slit filter installed between the x-ray source and the scanned object is reciprocated during a scan. The x-ray beams through the slits would generate relatively low-energy x-ray projection data, while the filtered beams would make high-energy projection data. An iterative image reconstruction algorithm that uses an adaptive-steepest-descent method to minimize image total-variation under the constraint of data fidelity was applied to reconstructing the image from the low-energy projection data. Since the high-energy projection data suffer from a substantially high noise level due to the beam filtration, we have developed a new algorithm that exploits the joint sparsity between the low- and high-energy CT images for image reconstruction of the high-energy CT image. The proposed image reconstruction algorithm uses a gradient magnitude image (GMI) of the low-energy CT image by regularizing the difference of GMIs of the low- and high-energy CT images to be minimized. The feasibility of the proposed technique has been demonstrated by the use of various phantoms in the experimental CBCT setup. Furthermore, based on the proposed dual-energy imaging, a material differentiation was performed and its potential utility has been shown. The proposed imaging technique produced promising results for its potential application to a low-dose single-scan dual-energy CBCT.

Mesh:

Year:  2017        PMID: 29192887     DOI: 10.1109/TMI.2017.2765760

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  3 in total

1.  Image reconstruction for interrupted-beam x-ray CT on diagnostic clinical scanners.

Authors:  Matthew J Muckley; Baiyu Chen; Thomas Vahle; Thomas O'Donnell; Florian Knoll; Aaron D Sodickson; Daniel K Sodickson; Ricardo Otazo
Journal:  Phys Med Biol       Date:  2019-08-07       Impact factor: 3.609

2.  A prior image constraint robust principal component analysis reconstruction method for sparse segmental multi-energy computed tomography.

Authors:  Bin Li; Ning Luo; Anni Zhong; Yongbao Li; Along Chen; Linghong Zhou; Yuan Xu
Journal:  Quant Imaging Med Surg       Date:  2021-09

3.  Simultaneous Image Reconstruction and Element Decomposition for Iodine Contrast Agent Visualization in Multienergy Element-Resolved Cone Beam CT.

Authors:  Chao Wang; Hyunuk Jung; Ming Yang; Chenyang Shen; Xun Jia
Journal:  Front Oncol       Date:  2022-02-01       Impact factor: 6.244

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.