Literature DB >> 29191457

The physics of small megavoltage photon beam dosimetry.

Pedro Andreo1.   

Abstract

The increased interest during recent years in the use of small megavoltage photon beams in advanced radiotherapy techniques has led to the development of dosimetry recommendations by different national and international organizations. Their requirement of data suitable for the different clinical options available, regarding treatment units and dosimetry equipment, has generated a considerable amount of research by the scientific community during the last decade. The multiple publications in the field have led not only to the availability of new invaluable data, but have also contributed substantially to an improved understanding of the physics of their dosimetry. This work provides an overview of the most important aspects that govern the physics of small megavoltage photon beam dosimetry.
Copyright © 2017 Elsevier B.V. All rights reserved.

Keywords:  Detector design; Detector material; Dosimetry protocols; Small fields dosimetry

Mesh:

Year:  2017        PMID: 29191457     DOI: 10.1016/j.radonc.2017.11.001

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  12 in total

1.  Beam commissioning of the first clinical biology-guided radiotherapy system.

Authors:  Bin Han; Dante Capaldi; Nataliya Kovalchuk; Eric Simiele; John White; Daniel Zaks; Lei Xing; Murat Surucu
Journal:  J Appl Clin Med Phys       Date:  2022-04-28       Impact factor: 2.243

2.  A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in megavoltage photon beams.

Authors:  Božidar Casar; Eduard Gershkevitsh; Ignasi Mendez; Slaven Jurković; M Saiful Huq
Journal:  Med Phys       Date:  2018-12-24       Impact factor: 4.071

3.  SciFi detector and associated method for real-time determination of profile and output factor for small fields in stereotactic radiotherapy.

Authors:  P Pittet; J Esteves; J-M Galvan; G-N Lu; F Blanc; G Haefeli; P Hopchev; S Rit; L Desbat; J Ribouton; P Jalade
Journal:  Med Phys       Date:  2020-01-30       Impact factor: 4.071

4.  "Characterization of ELEKTA SRS cone collimator using high spatial resolution monolithic silicon detector array".

Authors:  Khalsa Al Shukaili; Stéphanie Corde; Marco Petasecca; Vladimir Pereveratylo; Michael Lerch; Michael Jackson; Anatoly Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2018-05-22       Impact factor: 2.102

5.  Two-dimensional solid-state array detectors: A technique for in vivo dose verification in a variable effective area.

Authors:  Kananan Utitsarn; Giordano Biasi; Nauljun Stansook; Ziyad A Alrowaili; Marco Petasecca; Martin Carolan; Vladimir L Perevertaylo; Wolfgang A Tomé; Tomas Kron; Michael L F Lerch; Anatoly B Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2019-10-14       Impact factor: 2.102

6.  A multi-center output factor intercomparison to uncover systematic inaccuracies in small field dosimetry.

Authors:  Stefania Clemente; Laura Masi; Christian Fiandra; Elisabetta Cagni; Elena Villaggi; Marco Esposito; Francesca Romana Giglioli; Carmelo Marino; Lidia Strigari; Cristina Garibaldi; Michele Stasi; Pietro Mancosu; Serenella Russo
Journal:  Phys Imaging Radiat Oncol       Date:  2018-03-26

7.  Investigation of Collapsed-cone Algorithm Accuracy in Small Fields and Heterogeneous Environments.

Authors:  Razieh Zaghian; Abdolazim Sedighi Pashaki; Abbas Haghparast; Mohammad Hadi Gholami; Mahdi Mohammadi
Journal:  J Biomed Phys Eng       Date:  2021-04-01

8.  Feasibility study evaluating arrhythmogenesis and cardiac damage after heart-base irradiation in mice: A brief communication.

Authors:  James Elliott; Keith Linder; Michael W Nolan
Journal:  Vet Med Sci       Date:  2020-06-10

9.  PRIMO Monte Carlo software benchmarked against a reference dosimetry dataset for 6 MV photon beams from Varian linacs.

Authors:  Marcelino Hermida-López; David Sánchez-Artuñedo; Juan Francisco Calvo-Ortega
Journal:  Radiat Oncol       Date:  2018-08-07       Impact factor: 3.481

10.  Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams.

Authors:  Attia Gul; Shigekazu Fukuda; Hideyuki Mizuno; Nakaji Taku; M Basim Kakakhel; Sikander M Mirza
Journal:  J Appl Clin Med Phys       Date:  2020-10-19       Impact factor: 2.243

View more