Literature DB >> 29185835

Biometric Differences between Unilateral Chronic Primary Angle Closure Glaucoma and Fellow Non-Glaucomatous Eyes.

Wei Wang1, Xinyi Li1, Shida Chen1, Wenbin Huang1, Xiulan Zhang1.   

Abstract

PURPOSE: To compare biometric differences between eyes with unilateral chronic primary angle-closure glaucoma (PACG) and fellow non-glaucomatous eyes in the same patient.
METHODS: Clinical data and imaging records of 17 patients with unilateral PACG were retrospectively reviewed. The fellow eyes with primary angle-closure (PAC) or primary angle-closure suspected (PACS) were grouped in Group 1. The PACG eyes were set as Group 2. The biometric parameters of both eyes were measured by IOL-Master, anterior segment optical coherence tomography (AS-OCT), and swept source OCT.
RESULTS: The iris area in Group 1 was significantly thicker than that in Group 2 (1.590 ± 0.267 versus 1.365 ± 0.352, P = 0.016). Choroidal thickness in the macular region was thicker in Group 1 than in Group 2, with statistical significance at inner temporal grid (282.7 ± 121.1 versus 191.6 ± 90.3, P = 0.036), central field (297.4 ± 130.6 versus 200.1 ± 96.3, P = 0.029), inner nasal grid (283.1 ± 128.3 versus 194.8 ± 91.8, P = 0.040), and average value (265.3 ± 105.6 versus 191.1 ± 87.0, P = 0.049). Group 1 also had thicker peripapillary choroidal thickness at 1 o'clock (141.4 ± 68.4 versus 101.8 ± 39.0, P = 0.025) and 12 o'clock (141.5 ± 82.3 versus 104.5 ± 44.6, P = 0.037) compared to Group 2. The multivariate logistic regression analyses showed that only intraocular pressure was independently associated with PACG and explained 58.3% variance of PACG.
CONCLUSIONS: In unilateral PACG, there was significant inter-eye difference in anterior and posterior segment parameters. Longitudinal comparisons are required to further understand the differences in pathology of angle closures.

Entities:  

Keywords:  AS-OCT; biometry; glaucoma/angle-closure; optical coherence tomography; swept-source OCT

Mesh:

Year:  2017        PMID: 29185835     DOI: 10.1080/08820538.2017.1375121

Source DB:  PubMed          Journal:  Semin Ophthalmol        ISSN: 0882-0538            Impact factor:   1.975


  2 in total

1.  Ocular biometry through fully refocused steady-state magnetic resonance imaging sequence: reliability and agreement with the IOLMaster® 500.

Authors:  Lorenzo Ismael Perez-Sanchez; Julia Gutierrez-Vazquez; Maria Satrustegui-Lapetra; Francisco Ferreira-Manuel; Juan Jose Arevalo-Manso; Juan Jesus Gomez-Herrera; Juan Jose Criado-Alvarez
Journal:  Int Ophthalmol       Date:  2021-02-23       Impact factor: 2.031

2.  EDI-OCT choroidal thickness in Posner-Schlossman syndrome.

Authors:  Xiujuan Guo; Di Chen; Shuke Luo; Jinfei Huang; Yanhao Li
Journal:  Int Ophthalmol       Date:  2020-01-02       Impact factor: 2.031

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.