Literature DB >> 29182056

Lesion Segmentation in Automated 3D Breast Ultrasound: Volumetric Analysis.

Richa Agarwal1, Oliver Diaz1, Xavier Lladó1, Albert Gubern-Mérida2, Joan C Vilanova3, Robert Martí1.   

Abstract

Mammography is the gold standard screening technique in breast cancer, but it has some limitations for women with dense breasts. In such cases, sonography is usually recommended as an additional imaging technique. A traditional sonogram produces a two-dimensional (2D) visualization of the breast and is highly operator dependent. Automated breast ultrasound (ABUS) has also been proposed to produce a full 3D scan of the breast automatically with reduced operator dependency, facilitating double reading and comparison with past exams. When using ABUS, lesion segmentation and tracking changes over time are challenging tasks, as the three-dimensional (3D) nature of the images makes the analysis difficult and tedious for radiologists. The goal of this work is to develop a semi-automatic framework for breast lesion segmentation in ABUS volumes which is based on the Watershed algorithm. The effect of different de-noising methods on segmentation is studied showing a significant impact ([Formula: see text]) on the performance using a dataset of 28 temporal pairs resulting in a total of 56 ABUS volumes. The volumetric analysis is also used to evaluate the performance of the developed framework. A mean Dice Similarity Coefficient of [Formula: see text] with a mean False Positive ratio [Formula: see text] has been obtained. The Pearson correlation coefficient between the segmented volumes and the corresponding ground truth volumes is [Formula: see text] ([Formula: see text]). Similar analysis, performed on 28 temporal (prior and current) pairs, resulted in a good correlation coefficient [Formula: see text] ([Formula: see text]) for prior and [Formula: see text] ([Formula: see text]) for current cases. The developed framework showed prospects to help radiologists to perform an assessment of ABUS lesion volumes, as well as to quantify volumetric changes during lesions diagnosis and follow-up.

Entities:  

Keywords:  ABUS (Automated Breast Ultrasound); breast cancer; lesion segmentation; temporal; volumetric analysis; watershed

Mesh:

Year:  2017        PMID: 29182056     DOI: 10.1177/0161734617737733

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  4 in total

1.  Improved Inception V3 method and its effect on radiologists' performance of tumor classification with automated breast ultrasound system.

Authors:  Panpan Zhang; Zhaosheng Ma; Yingtao Zhang; Xiaodan Chen; Gang Wang
Journal:  Gland Surg       Date:  2021-07

2.  Fully automated lesion segmentation and visualization in automated whole breast ultrasound (ABUS) images.

Authors:  Chia-Yen Lee; Tzu-Fang Chang; Yi-Hong Chou; Kuen-Cheh Yang
Journal:  Quant Imaging Med Surg       Date:  2020-03

3.  False-negative results on computer-aided detection software in preoperative automated breast ultrasonography of breast cancer patients.

Authors:  Youngjune Kim; Jiwon Rim; Sun Mi Kim; Bo La Yun; So Yeon Park; Hye Shin Ahn; Bohyoung Kim; Mijung Jang
Journal:  Ultrasonography       Date:  2020-03-24

4.  Application of Convolution Neural Network Algorithm Based on Multicenter ABUS Images in Breast Lesion Detection.

Authors:  Jianxing Zhang; Xing Tao; Yanhui Jiang; Xiaoxi Wu; Dan Yan; Wen Xue; Shulian Zhuang; Ling Chen; Liangping Luo; Dong Ni
Journal:  Front Oncol       Date:  2022-07-04       Impact factor: 5.738

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.