Literature DB >> 2917832

Contrast and accuracy of relaxation time measurements in acquired and synthesized multislice magnetic resonance images.

S Majumdar1, H D Sostman, J R MacFall.   

Abstract

The effects of interslice spacing, the number of data points and other factors on the accuracy of relaxation time measurements and contrast have been investigated for both acquired and synthesized multislice MR images using experiments and computer simulations. The cross-excitation between adjacent slices in multislice imaging affects both contrast and derived relaxation times. Such measurements also are affected by the T1 and T2 of the materials imaged, the pulse sequence timing parameters, and the number of data points used to estimate the relaxation times. Errors in T1 and T2 may be severe, particularly for slice spacings less than 0.5 slice thickness and for long T1 and T2 materials. Consequently, the difference in signal intensities between two materials with different relaxation times also varies with slice spacing and between acquired and synthetic images, particularly for strongly T1-weighed images.

Mesh:

Year:  1989        PMID: 2917832     DOI: 10.1097/00004424-198902000-00007

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  4 in total

1.  Near-contiguous spin echo imaging using matched-phase RF and its application in velocity-selective arterial spin labeling.

Authors:  Zungho Zun; Brian A Hargreaves; John Pauly; Greg Zaharchuk
Journal:  Magn Reson Med       Date:  2013-07-15       Impact factor: 4.668

2.  A synthetic cartilage extracellular matrix model: hyaluronan and collagen hydrogel relaxivity, impact of macromolecular concentration on dGEMRIC.

Authors:  Ediuska Laurens; Erika Schneider; Carl S Winalski; Anthony Calabro
Journal:  Skeletal Radiol       Date:  2011-12-15       Impact factor: 2.199

3.  Gray matter-white matter contrast on spin-echo T1-weighted images at 3 T and 1.5 T: a quantitative comparison study.

Authors:  Yasutaka Fushimi; Yukio Miki; Shin-Ichi Urayama; Tsutomu Okada; Nobuyuki Mori; Takashi Hanakawa; Hidenao Fukuyama; Kaori Togashi
Journal:  Eur Radiol       Date:  2007-07-07       Impact factor: 5.315

4.  Heat Modulation of Intrinsic MR Contrasts for Tumor Characterization.

Authors:  Matthew Tarasek; Oguz Akin; Jeannette Roberts; Thomas Foo; Desmond Yeo
Journal:  Cancers (Basel)       Date:  2022-01-14       Impact factor: 6.639

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.