[Bruch's membrane opening minimum rim width : Correlation and diagnostic accuracy in comparison to peripapillary retinal nerve fiber layer thickness].

M Awe1, S Khalili-Amiri2, I R Volkmann2, B Junker2, C Framme2, K Hufendiek3.   

Abstract

BACKGROUND: Glaucoma is one of the main causes of blindness in the Western hemisphere. Because the disease often painlessly progresses it remains unnoticed until major optic nerve head damage occurs in many cases. That is why new, more sensitive diagnostic methods are needed. Bruch's membrane opening minimum rim width (BMO-MRW), measured with the new glaucoma module premium edition (GMPE) was recently introduced as a more accurate tool to detect glaucomatous changes. The purpose of this study was to assess the correlation of SPECTRALIS® spectral domain optical coherence tomography (SD-OCT) and the GMPE anatomic positioning module (APS module) for retinal nerve fiber layer thickness (RNFLT) measurements. The second aim was to assess the diagnostic accuracy of BMO-MRW.
METHODS: Prospective study of 41 eyes (41 patients) with glaucoma and 26 eyes from 26 healthy controls. Scans were obtained using SPECTRALIS® SD-OCT and RNFLT was measured with both modules and compared using Spearman's rank test. The BMO-MRW was assessed by GMPE. Sensitivity, specificity and area under receiver operating characteristics curves (AUROC) of each sector of the optic nerve were calculated and compared using the method of Delong et al.
RESULTS: We found a positive correlation (0.694-0.955, p < 0.0001) between RNFLT measurements by standard SD-OCT and all diameters of RNFLT of APS module within all sectors. The AUROC of RNFLT in standard SD-OCT was 0.693 for the inferior nasal sector (NI) and BMO-MRW was 0.85 in NI. The difference in AUROC was statistically significant (p = 0.0049). No other sector showed statistically significant differences.
CONCLUSION: The RNFLT measurements of both modules showed a positive correlation and appear to be comparable. The BMO-MRW in one sector (NI) showed a significantly higher accuracy of measurement than standard RNFLT. All other sectors showed a comparable accuracy of measurement.

Entities:  

Keywords:  Bruch’s Membrane Opening; Glaucoma; Glaucoma diagnostics; Minimum rim width; Optical coherence tomography

Mesh:

Year:  2019        PMID: 29177702     DOI: 10.1007/s00347-017-0616-6

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  25 in total

1.  Basic principles of ROC analysis.

Authors:  C E Metz
Journal:  Semin Nucl Med       Date:  1978-10       Impact factor: 4.446

2.  Influence of clinically invisible, but optical coherence tomography detected, optic disc margin anatomy on neuroretinal rim evaluation.

Authors:  Alexandre S C Reis; Neil O'Leary; Hongli Yang; Glen P Sharpe; Marcelo T Nicolela; Claude F Burgoyne; Balwantray C Chauhan
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-04-18       Impact factor: 4.799

Review 3.  Retinal optical coherence tomography: past, present and future perspectives.

Authors:  Wolfgang Geitzenauer; Christoph K Hitzenberger; Ursula M Schmidt-Erfurth
Journal:  Br J Ophthalmol       Date:  2010-07-31       Impact factor: 4.638

4.  Automated segmentation of neural canal opening and optic cup in 3D spectral optical coherence tomography volumes of the optic nerve head.

Authors:  Zhihong Hu; Michael D Abràmoff; Young H Kwon; Kyungmoo Lee; Mona K Garvin
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-06-16       Impact factor: 4.799

Review 5.  Spectral domain optical coherence tomography: a better OCT imaging strategy.

Authors:  Zahid Yaqoob; Jigang Wu; Changhuei Yang
Journal:  Biotechniques       Date:  2005-12       Impact factor: 1.993

6.  On some Points in the Pathology and Morbid Anatomy of Glaucoma.

Authors:  J W Hulke
Journal:  Med Chir Trans       Date:  1858

Review 7.  Pathophysiology of human glaucomatous optic nerve damage: insights from rodent models of glaucoma.

Authors:  John C Morrison; William O Cepurna Ying Guo; Elaine C Johnson
Journal:  Exp Eye Res       Date:  2010-08-11       Impact factor: 3.467

8.  Optic disc margin anatomy in patients with glaucoma and normal controls with spectral domain optical coherence tomography.

Authors:  Alexandre S C Reis; Glen P Sharpe; Hongli Yang; Marcelo T Nicolela; Claude F Burgoyne; Balwantray C Chauhan
Journal:  Ophthalmology       Date:  2012-01-04       Impact factor: 12.079

9.  Estimation and Comparison of Receiver Operating Characteristic Curves.

Authors:  Margaret Pepe; Gary Longton; Holly Janes
Journal:  Stata J       Date:  2009-03-01       Impact factor: 2.637

10.  Spectral domain optical coherence tomography in glaucoma: qualitative and quantitative analysis of the optic nerve head and retinal nerve fiber layer (an AOS thesis).

Authors:  Teresa C Chen
Journal:  Trans Am Ophthalmol Soc       Date:  2009-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.