Literature DB >> 29171091

Internal fit of three-unit fixed dental prostheses produced by computer-aided design/computer-aided manufacturing and the lost-wax metal casting technique assessed using the triple-scan protocol.

Bjørn E Dahl1, Jon E Dahl2,3, Hans J Rønold1.   

Abstract

Suboptimal adaptation of fixed dental prostheses (FDPs) can lead to technical and biological complications. It is unclear if the computer-aided design/computer-aided manufacturing (CAD/CAM) technique improves adaptation of FDPs compared with FDPs made using the lost-wax and metal casting technique. Three-unit FDPs were manufactured by CAD/CAM based on digital impression of a typodont model. The FDPs were made from one of five materials: pre-sintered zirconium dioxide; hot isostatic pressed zirconium dioxide; lithium disilicate glass-ceramic; milled cobalt-chromium; and laser-sintered cobalt-chromium. The FDPs made using the lost-wax and metal casting technique were used as reference. The fit of the FDPs was analysed using the triple-scan method. The fit was evaluated for both single abutments and three-unit FDPs. The average cement space varied between 50 μm and 300 μm. Insignificant differences in internal fit were observed between the CAD/CAM-manufactured FDPs, and none of the FPDs had cement spaces that were statistically significantly different from those of the reference FDP. For all FDPs, the cement space at a marginal band 0.5-1.0 mm from the preparation margin was less than 100 μm. The milled cobalt-chromium FDP had the closest fit. The cement space of FDPs produced using the CAD/CAM technique was similar to that of FDPs produced using the conventional lost-wax and metal casting technique.
© 2017 Eur J Oral Sci.

Entities:  

Keywords:  CAD/CAM; cement space; dental crown; lithium disilicate glass-ceramic; zirconium dioxide

Mesh:

Substances:

Year:  2017        PMID: 29171091     DOI: 10.1111/eos.12394

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  3 in total

Review 1.  A systematic review on the accuracy of zirconia crowns and fixed dental prostheses.

Authors:  Per Svanborg
Journal:  Biomater Investig Dent       Date:  2020-01-07

2.  Comparison of internal fit of metal-ceramic crowns in CAD/CAM and lost-wax techniques in all fabrication stages through replica weighting, triple scanning, and scanning electron microscope.

Authors:  Sina Mohammadi Sadr; Elham Ahmadi; Masoumeh Hasani Tabatabaei; Saba Mohammadi; Faezeh Atri
Journal:  Clin Exp Dent Res       Date:  2022-02-20

3.  Marginal and internal fit of crowns based on additive or subtractive manufacturing.

Authors:  Yasser Haddadi; Bahram Ranjkesh; Flemming Isidor; Golnosh Bahrami
Journal:  Biomater Investig Dent       Date:  2021-06-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.