Performance of a hybrid Monte Carlo-Pencil Beam dose algorithm for proton therapy inverse planning.

Ana María Barragán Montero1, Kevin Souris1, Daniel Sanchez-Parcerisa2, Edmond Sterpin1,3, John Aldo Lee1.   

Abstract

PURPOSE: Analytical algorithms have a limited accuracy when modeling very heterogeneous tumor sites. This work addresses the performance of a hybrid dose optimizer that combines both Monte Carlo (MC) and pencil beam (PB) dose engines to get the best trade-off between speed and accuracy for proton therapy plans.
METHODS: The hybrid algorithm calculates the optimal spot weights (w) by means of an iterative optimization process where the dose at each iteration is computed by using a precomputed dose influence matrix based on the conventional PB plus a correction term c obtained from a MC simulation. Updates of c can be triggered as often as necessary by calling the MC dose engine with the last corrected values of w as input. In order to analyze the performance of the hybrid algorithm against dose calculation errors, it was applied to a simplistic water phantom for which several test cases with different errors were simulated, including proton range uncertainties. Afterwards, the algorithm was used in three clinical cases (prostate, lung, and brain) and benchmarked against full MC-based optimization. The influence of different stopping criteria in the final results was also investigated.
RESULTS: The hybrid algorithm achieved excellent results provided that the estimated range in a homogeneous material is the same for the two dose engines involved, i.e., PB and MC. For the three patient cases, the hybrid plans were clinically equivalent to those obtained with full MC-based optimization. Only a single update of c was needed in the hybrid algorithm to fulfill the clinical dose constraints, which represents an extra computation time to obtain c that ranged from 1 (brain) to 4 min (lung) with respect to the conventional PB-based optimization, and an estimated average gain factor of 14 with respect to full MC-based optimization.
CONCLUSION: The hybrid algorithm provides an improved trade-off between accuracy and speed. This algorithm can be immediately considered as an option for improving dose calculation accuracy of commercial analytical treatment planning systems, without a significant increase in the computation time (≪5 min) with respect to current PB-based optimization.
© 2017 American Association of Physicists in Medicine.

Entities:  

Keywords:  dose engine; inverse planning; proton therapy

Mesh:

Year:  2017        PMID: 29159915     DOI: 10.1002/mp.12688

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

Review 1.  Adaptive proton therapy.

Authors:  Harald Paganetti; Pablo Botas; Gregory C Sharp; Brian Winey
Journal:  Phys Med Biol       Date:  2021-11-15       Impact factor: 3.609

2.  Investigation on Patient/Compensator Scatter Factor for Monitor Unit Calculation in Proton Therapy.

Authors:  Michael T Prusator; Salahuddin Ahmad; Yong Chen
Journal:  Int J Part Ther       Date:  2018-11-30

3.  Teaching treatment planning for protons with educational open-source software: experience with FoCa and matRad.

Authors:  Daniel Sanchez-Parcerisa; Jose Udías
Journal:  J Appl Clin Med Phys       Date:  2018-05-12       Impact factor: 2.102

4.  Linear Energy Transfer Incorporated Spot-Scanning Proton Arc Therapy Optimization: A Feasibility Study.

Authors:  Xiaoqiang Li; Xuanfeng Ding; Weili Zheng; Gang Liu; Guillaume Janssens; Kevin Souris; Ana M Barragán-Montero; Di Yan; Craig Stevens; Peyman Kabolizadeh
Journal:  Front Oncol       Date:  2021-07-12       Impact factor: 6.244

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.