Alessandro Scotti1,2,3, Rong-Wen Tain1,2, Weiguo Li4,5, Victoria Gil6, Chong Wee Liew6, Kejia Cai1,2. 1. Department of Radiology, University of Illinois at Chicago, Illinois, USA. 2. Center for MR Research, University of Illinois at Chicago, Illinois, USA. 3. Department of Bioengineering, University of Illinois at Chicago, Illinois, USA. 4. Research Resources Center, University of Illinois at Chicago, Illinois, USA. 5. Department of Radiology, Northwestern University, Chicago, Illinois, USA. 6. Department of Physiology and Biophysics, University of Illinois at Chicago, Illinois, USA.
Abstract
BACKGROUND: Brown adipose tissue (BAT) has a great relevance in metabolic diseases and has been shown to be reduced in obesity and insulin resistance patients. Currently, Dixon MRI is used to calculate fat-water fraction (FWF) and differentiate BAT from white adipose tissue (WAT). However, it may fail in areas of phase wrapping and introduce fat-water swapping artifacts. PURPOSE: To investigate the capacity of the Z-spectrum imaging (ZSI) for the identification of BAT in vivo. STUDY TYPE: Retrospective study. SPECIMENS: WAT, BAT, and lean tissue from healthy mice. ANIMALS: Four C57BL/6 healthy mice. POPULATION: Five healthy volunteers. FIELD STRENGTH: 9.4T, 3T for volunteers. SEQUENCE: Z-Spectra data were fitted to a model with three Lorentzian peaks reflecting the direct saturation of tissue water (W) and methylene fat (F), and the magnetization transfer from the semi-solid tissues. The peak amplitudes of water and fat were used to map the FWF. The novel FWF metric was calibrated with an oil and water mixture phantom and validated in specimens, mice and human subjects. ASSESSMEMT: FWF distribution was compared with published works and values compared with Dixon's MRI results. STATISTICAL TESTS: Comparisons were performed by t-tests. RESULTS: ZSI clearly differentiated WAT, BAT, and lean tissues by having FWF = 1, 0.5, and 0, respectively. Calibration with oil mixture phantoms revealed a linear relationship between FWF and the actual fat fraction (R2 = 0.98). In vivo experiments in mice confirmed in vitro results by showing FWF = 0.6 in BAT. FWF maps of human subjects showed the same FWF distribution as Dixon's MRI (P > 0.05). ZSI is independent from B0 field inhomogeneity and fat-water swapping because both lipid and water frequency offsets are determined simultaneously during Z-spectral fitting. DATA CONCLUSION: ZSI can derive artifact-free FWF maps, which can be used to identify BAT distribution in vivo noninvasively. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1527-1533.
BACKGROUND: Brown adipose tissue (BAT) has a great relevance in metabolic diseases and has been shown to be reduced in obesity and insulin resistance patients. Currently, Dixon MRI is used to calculate fat-water fraction (FWF) and differentiate BAT from white adipose tissue (WAT). However, it may fail in areas of phase wrapping and introduce fat-water swapping artifacts. PURPOSE: To investigate the capacity of the Z-spectrum imaging (ZSI) for the identification of BAT in vivo. STUDY TYPE: Retrospective study. SPECIMENS: WAT, BAT, and lean tissue from healthy mice. ANIMALS: Four C57BL/6 healthy mice. POPULATION: Five healthy volunteers. FIELD STRENGTH: 9.4T, 3T for volunteers. SEQUENCE: Z-Spectra data were fitted to a model with three Lorentzian peaks reflecting the direct saturation of tissue water (W) and methylene fat (F), and the magnetization transfer from the semi-solid tissues. The peak amplitudes of water and fat were used to map the FWF. The novel FWF metric was calibrated with an oil and water mixture phantom and validated in specimens, mice and human subjects. ASSESSMEMT: FWF distribution was compared with published works and values compared with Dixon's MRI results. STATISTICAL TESTS: Comparisons were performed by t-tests. RESULTS:ZSI clearly differentiated WAT, BAT, and lean tissues by having FWF = 1, 0.5, and 0, respectively. Calibration with oil mixture phantoms revealed a linear relationship between FWF and the actual fat fraction (R2 = 0.98). In vivo experiments in mice confirmed in vitro results by showing FWF = 0.6 in BAT. FWF maps of human subjects showed the same FWF distribution as Dixon's MRI (P > 0.05). ZSI is independent from B0 field inhomogeneity and fat-water swapping because both lipid and water frequency offsets are determined simultaneously during Z-spectral fitting. DATA CONCLUSION:ZSI can derive artifact-free FWF maps, which can be used to identify BAT distribution in vivo noninvasively. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1527-1533.
Authors: Samuel Fuller; Scott Reeder; Ann Shimakawa; Huanzhou Yu; Jane Johnson; Christopher Beaulieu; Garry E Gold Journal: AJR Am J Roentgenol Date: 2006-12 Impact factor: 3.959
Authors: Thorsten A Bley; Oliver Wieben; Christopher J François; Jean H Brittain; Scott B Reeder Journal: J Magn Reson Imaging Date: 2010-01 Impact factor: 4.813