Jun Wang 1,2 , Jan Vargas 2 , Alejandro Spiotta 2 , Imran Chaudry 2 , Raymond D Turner 2 , Jonathan Lena 2 , Aquilla Turk 2 . Show Affiliations »
Abstract
OBJECTIVE: This study retrospectively compared the clinical and angiographic outcomes of treating cerebral aneurysms with Neuroform (NEU), Enterprise (EP), and Low-profile Visualized Intraluminal Support (LVIS/LVIS Jr) stents. MATERIALS AND METHODS: We conducted a retrospective analysis of a procedural database. All aneurysm procedures using any of the three types of self-expanding nitinol stents (NEU, EP and LVIS/LVIS Jr) were included. Intra-procedure complications, post-procedure complications, and angiographic results (Raymond-Roy grade scale, RRGS) were analyzed retrospectively. A multivariate logistic regression analysis was conducted to identify predictors of intra-procedure and post-procedure complications. RESULTS: Two hundred and forty-three aneurysms in 229 patients treated with stent-assisted coiling were included (NEU group: 109 aneurysms; EP group: 61 aneurysms; LVIS/LVIS Jr: 73 aneurysms). The LVIS/LVIS Jr group was associated with the lowest rate of initial complete occlusion (RRGS I: 47.9%; 35/73). Follow-up showed the proportion of RRGS I increased for all stent groups but was greatest in the LVIS/LVIS Jr group. Overall, 17 intra-procedural complications were seen in 229 patients (7.4%) and 15 post-procedural complications were found in 198 patients at follow-up (7.6%), with no differences between stent groups. Thrombotic events were the most common complications and occurred in 13 patients (13/229, 5.7%). CONCLUSIONS: All three types of stents used to treat cerebral aneurysms with unfavorable neck were safe and effective, providing suitable support for the coil mass. LVIS/LVIS Jr promotes better progressive aneurysm complete occlusion than the other two stents but seems to cause more common intra-procedural stent-related thrombotic events and fewer post-procedural complications. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
OBJECTIVE: This study retrospectively compared the clinical and angiographic outcomes of treating cerebral aneurysms with Neuroform (NEU ), Enterprise (EP), and Low-profile Visualized Intraluminal Support (LVIS/LVIS Jr) stents. MATERIALS AND METHODS: We conducted a retrospective analysis of a procedural database. All aneurysm procedures using any of the three types of self-expanding nitinol stents (NEU , EP and LVIS/LVIS Jr) were included. Intra-procedure complications, post-procedure complications, and angiographic results (Raymond-Roy grade scale, RRGS) were analyzed retrospectively. A multivariate logistic regression analysis was conducted to identify predictors of intra-procedure and post-procedure complications. RESULTS: Two hundred and forty-three aneurysms in 229 patients treated with stent-assisted coiling were included (NEU group: 109 aneurysms ; EP group: 61 aneurysms ; LVIS/LVIS Jr: 73 aneurysms ). The LVIS/LVIS Jr group was associated with the lowest rate of initial complete occlusion (RRGS I: 47.9%; 35/73). Follow-up showed the proportion of RRGS I increased for all stent groups but was greatest in the LVIS/LVIS Jr group. Overall, 17 intra-procedural complications were seen in 229 patients (7.4%) and 15 post-procedural complications were found in 198 patients at follow-up (7.6%), with no differences between stent groups. Thrombotic events were the most common complications and occurred in 13 patients (13/229, 5.7%). CONCLUSIONS: All three types of stents used to treat cerebral aneurysms with unfavorable neck were safe and effective, providing suitable support for the coil mass. LVIS/LVIS Jr promotes better progressive aneurysm complete occlusion than the other two stents but seems to cause more common intra-procedural stent-related thrombotic events and fewer post-procedural complications. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Entities: Chemical
Disease
Species
Keywords:
aneurysm
Mesh: See more »
Year: 2017
PMID: 29146831 DOI: 10.1136/neurintsurg-2017-013272
Source DB: PubMed Journal: J Neurointerv Surg ISSN: 1759-8478 Impact factor: 5.836