BACKGROUND: Extensive past work showed that noninvasive continuous glucose monitoring with a wearable multisensor device worn on the upper arm provides useful information about glucose trends to improve diabetes therapy in controlled and semicontrolled conditions.
METHOD: To test previous findings also in uncontrolled conditions, a long term at home study has been organized to collect multisensor and reference glucose data in a population of 20 type 1 diabetes subjects. A total of 1072 study days were collected and a fully on-line compatible algorithmic routine linking multisensor data to glucose applied to estimate glucose levels noninvasively.
RESULTS: The algorithm used here calculates glucose values from sensor data and adds a constant obtained by a daily calibration. It provides point inaccuracy measured by a MARD of 35.4 mg/dL on test data. This is higher than current state-of-the-art minimally invasive devices, but still 86.9% of glucose rate points fall within the zone AR+BR.
CONCLUSIONS: The multisensor device and the algorithmic routine used earlier in controlled conditions tracks glucose changes also in uncontrolled conditions, although with lower accuracy. The examination of learning curves suggests that obtaining more data would not improve the results. Therefore, further efforts would focus on the development of more complex algorithmic routines able to compensate for environmental and physiological confounders better.

Entities:  

Keywords:  T1DM; algorithm; diabetes; dielectric spectroscopy; multisensor

Mesh:

Substances:

Year:  2017        PMID: 29145749      PMCID: PMC6154230          DOI: 10.1177/1932296817740591

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  40 in total

1.  The effect of blood content on the optical and dielectric skin properties.

Authors:  P Zakharov; F Dewarrat; A Caduff; M S Talary
Journal:  Physiol Meas       Date:  2010-12-08       Impact factor: 2.833

2.  Non-invasive continuous glucose monitoring: improved accuracy of point and trend estimates of the Multisensor system.

Authors:  Mattia Zanon; Giovanni Sparacino; Andrea Facchinetti; Michela Riz; Mark S Talary; Roland E Suri; Andreas Caduff; Claudio Cobelli
Journal:  Med Biol Eng Comput       Date:  2012-06-22       Impact factor: 2.602

3.  Development of a high-sensitivity and portable cell using Helmholtz resonance for noninvasive blood glucose-level measurement based on photoacoustic spectroscopy.

Authors:  K Tachibana; K Okada; R Kobayashi; Y Ishihara
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2016-08

4.  Depth-selective photothermal IR spectroscopy of skin: potential application for non-invasive glucose measurement.

Authors:  Otto Hertzberg; Alexander Bauer; Arne Küderle; Miguel A Pleitez; Werner Mäntele
Journal:  Analyst       Date:  2017-01-26       Impact factor: 4.616

5.  Evaluating clinical accuracy of systems for self-monitoring of blood glucose.

Authors:  W L Clarke; D Cox; L A Gonder-Frederick; W Carter; S L Pohl
Journal:  Diabetes Care       Date:  1987 Sep-Oct       Impact factor: 19.112

6.  Closing the Loop in Adults, Children and Adolescents With Suboptimally Controlled Type 1 Diabetes Under Free Living Conditions: A Psychosocial Substudy.

Authors:  Katharine D Barnard; Timothy Wysocki; Vanessa Ully; Julia K Mader; Thomas R Pieber; Hood Thabit; Martin Tauschmann; Lalantha Leelarathna; Sara Hartnell; Carlo L Acerini; Malgorzata E Wilinska; Sibylle Dellweg; Carsten Benesch; Sabine Arnolds; Manuel Holzer; Harald Kojzar; Fiona Campbell; James Yong; Jennifer Pichierri; Peter Hindmarsh; Lutz Heinemann; Mark L Evans; Roman Hovorka
Journal:  J Diabetes Sci Technol       Date:  2017-04-03

7.  Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy.

Authors:  Rishikesh Pandey; Santosh Kumar Paidi; Tulio A Valdez; Chi Zhang; Nicolas Spegazzini; Ramachandra Rao Dasari; Ishan Barman
Journal:  Acc Chem Res       Date:  2017-01-10       Impact factor: 22.384

8.  Use of continuous glucose monitoring as an outcome measure in clinical trials.

Authors:  Roy W Beck; Peter Calhoun; Craig Kollman
Journal:  Diabetes Technol Ther       Date:  2012-10       Impact factor: 6.118

9.  Reconstruction of glucose in plasma from interstitial fluid continuous glucose monitoring data: role of sensor calibration.

Authors:  Andrea Facchinetti; Giovanni Sparacino; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2007-09

Review 10.  Continuous Glucose Monitoring Sensors: Past, Present and Future Algorithmic Challenges.

Authors:  Andrea Facchinetti
Journal:  Sensors (Basel)       Date:  2016-12-09       Impact factor: 3.576

View more
  6 in total

Review 1.  Continuous noninvasive glucose monitoring; water as a relevant marker of glucose uptake in vivo.

Authors:  Andreas Caduff; Paul Ben Ishai; Yuri Feldman
Journal:  Biophys Rev       Date:  2019-11-18

2.  The first survey on patient needs for remote monitoring of cardiac implantable electronic device in South Korea.

Authors:  You Mi Hwang; Ji-Hoon Kim
Journal:  Medicine (Baltimore)       Date:  2022-06-10       Impact factor: 1.817

Review 3.  Sense and Learn: Recent Advances in Wearable Sensing and Machine Learning for Blood Glucose Monitoring and Trend-Detection.

Authors:  Ahmad Yaser Alhaddad; Hussein Aly; Hoda Gad; Abdulaziz Al-Ali; Kishor Kumar Sadasivuni; John-John Cabibihan; Rayaz A Malik
Journal:  Front Bioeng Biotechnol       Date:  2022-05-12

Review 4.  Review of Non-invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone.

Authors:  Maryamsadat Shokrekhodaei; Stella Quinones
Journal:  Sensors (Basel)       Date:  2020-02-25       Impact factor: 3.576

5.  Smart-watch-programmed green-light-operated percutaneous control of therapeutic transgenes.

Authors:  Maysam Mansouri; Marie-Didiée Hussherr; Tobias Strittmatter; Peter Buchmann; Shuai Xue; Gieri Camenisch; Martin Fussenegger
Journal:  Nat Commun       Date:  2021-06-07       Impact factor: 14.919

Review 6.  Commercial and Scientific Solutions for Blood Glucose Monitoring-A Review.

Authors:  Yirui Xue; Angelika S Thalmayer; Samuel Zeising; Georg Fischer; Maximilian Lübke
Journal:  Sensors (Basel)       Date:  2022-01-06       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.