Effect of Distal Implant Inclination on Dislodging Forces of Different Locator Attachments Used for Mandibular Overdentures: An In Vitro Study.

Moustafa Abdou ELsyad1, Radwa Mohsen Emera1, Tarek Mohy Ashmawy2.   

Abstract

PURPOSE: To evaluate the effect of distal implant inclination on axial and nonaxial retentive forces of different Locator attachments used to retain mandibular overdentures.
MATERIALS AND METHODS: Four duplicate mandibular edentulous acrylic models received 2 implants in the canine areas with 0°, 5°, 10°, and 20° distal inclinations. Experimental overdentures were connected to the implants with Locator extra light retention (Le), Locator light retention (Ll), and Locator medium retention (Lm). For the 20° model, extended range Locator extra-light retention (Lee) and Locator medium retention (Lem) were used. Axial and nonaxial (anterior, posterior, lateral) retentive forces were measured initially and after 540 cycles of denture insertion and removal. Three-way mixed ANOVA was used to analyze axial and nonaxial retentive forces
RESULTS: After wear simulation, 20° angulation showed the highest axial retention for Le and Ll while 5° showed the highest retention for Lm; 0° and 5° showed the highest anterior and posterior retention for Lm; 20° showed the highest lateral retention for Le and Ll. For all implant inclinations, Lm showed the highest axial and nonaxial retention, and Le and Lee showed the lowest retention for 10° and 20° inclined implants, respectively.
CONCLUSIONS: Axial and nonaxial retention of Locator attachments for implant-retained overdentures are significantly affected by the degree of distal implant inclination and the type of nylon inserts. Lm is recommended to retain overdentures when implants have 5° or 10° distal inclination, and Le and Ll are recommended with 20° inclination to maintain high axial and nonaxial retention after wear.
© 2017 by the American College of Prosthodontists.

Entities:  

Keywords:  Attachment; Locator; implant inclinations; overdenture; retention

Mesh:

Year:  2017        PMID: 29143403     DOI: 10.1111/jopr.12710

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  2 in total

Review 1.  Evaluation of Retention, Wear, and Maintenance of Attachment Systems for Single- or Two-Implant-Retained Mandibular Overdentures: A Systematic Review.

Authors:  Raphaël Wakam; Aurélie Benoit; Kwamivi Bernardin Mawussi; Caroline Gorin
Journal:  Materials (Basel)       Date:  2022-03-04       Impact factor: 3.623

2.  Effect of Implant Positions and Angulations on Retentive Strength of 2-Implant Mandibular Overdentures: An In Vitro Study with the New 3D-Printed Simulation Method.

Authors:  Pravinkumar G Patil; Liang Lin Seow; Rashmi Uddanwadikar; Allan Pau; Piyush D Ukey
Journal:  Int J Dent       Date:  2022-09-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.