Literature DB >> 29141750

Use of a Novel Portable Three-Dimensional Imaging System to Measure Limb Volume and Circumference in Patients with Filarial Lymphedema.

Channa Yahathugoda1, Michael J Weiler2, Ramakrishna Rao3, Lalindi De Silva1, J Brandon Dixon4, Mirani V Weerasooriya1, Gary J Weil3, Philip J Budge3.   

Abstract

The World Health Organization's Global Program to Eliminate Lymphatic Filariasis (LF) has reduced LF transmission worldwide, but millions remain affected by filarial lymphedema. Tools for clinically monitoring lymphedema in developing nations are limited. We tested a novel, portable, infrared three-dimensional imaging system (3DIS) against water displacement (WD) and tape measurement of limb circumference (TMLC) among patients with filarial leg lymphedema in Galle, Sri Lanka. Outcomes were accuracy and reproducibility of imaging system measurements. In parallel, we also tested the reproducibility of skin thickness ultrasound (STU) measurements. We examined 52 patients (104 limbs) with lymphedema of stages 0-6 (N = 28, 19, 20, 21, 2, 4, and 10, respectively). 3DIS measurements correlated nearly perfectly with WD (r2 = 0.9945) and TMLC values (r2 > 0.9801). The median time required to acquire imaging system measurements for both legs was 2.1 minutes, compared with 17, 7, and 29 minutes, respectively, for WD, TMLC, and STU. Median interexaminer coefficients of variation (CVs) for volume measurements were 1.1% (interquartile range [IQR] 0.5-2.1%) for WD and 1.7% (IQR 1.2-2.4%) for the 3DIS. CVs for circumference measurements were 1.4% (IQR 0.8-2.4%) by TMLC and 1.3% (0.8-1.9%) by 3DIS. Median interexaminer CV for STU was 13.7% (IQR 8.5-21.3%). The portable imaging system noninvasively provided accurate and reproducible limb volume and circumference measurements in approximately 2 minutes per patient. This portable technology has the potential to greatly improve assessment and monitoring of lymphedema in the clinic and in the field.

Entities:  

Mesh:

Year:  2017        PMID: 29141750      PMCID: PMC5805069          DOI: 10.4269/ajtmh.17-0504

Source DB:  PubMed          Journal:  Am J Trop Med Hyg        ISSN: 0002-9637            Impact factor:   2.345


  11 in total

1.  Lymphatic filariasis: the disease and its control. Fifth report of the WHO Expert Committee on Filariasis.

Authors: 
Journal:  World Health Organ Tech Rep Ser       Date:  1992

2.  489 Global programme to eliminate lymphatic filariasis: progress report, 2014.

Authors: 
Journal:  Wkly Epidemiol Rec       Date:  2015-09-18

3.  Limb circumference measurement for recording edema volume in patients with filarial lymphedema.

Authors:  S P Pani; P Vanamail; J Yuvaraj
Journal:  Lymphology       Date:  1995-06       Impact factor: 1.286

4.  Three-dimensional camera system for measuring arm volume in women with lymphedema following breast cancer treatment.

Authors:  Fredrik Ohberg; Adam Zachrisson; Åsa Holmner-Rocklöv
Journal:  Lymphat Res Biol       Date:  2014-12       Impact factor: 2.589

5.  3D stereophotogrammetry in upper-extremity lymphedema: An accurate diagnostic method.

Authors:  Marijn Hameeteman; Arico C Verhulst; Rinaldo D Vreeken; Thomas J J Maal; Dietmar J O Ulrich
Journal:  J Plast Reconstr Aesthet Surg       Date:  2015-10-22       Impact factor: 2.740

Review 6.  Lymphedema: a comprehensive review.

Authors:  Anne G Warren; Håkan Brorson; Loren J Borud; Sumner A Slavin
Journal:  Ann Plast Surg       Date:  2007-10       Impact factor: 1.539

7.  Measuring and representing peripheral oedema and its alterations.

Authors:  J R Casley-Smith
Journal:  Lymphology       Date:  1994-06       Impact factor: 1.286

8.  Doxycycline improves filarial lymphedema independent of active filarial infection: a randomized controlled trial.

Authors:  Sabine Mand; Alexander Yaw Debrah; Ute Klarmann; Linda Batsa; Yeboah Marfo-Debrekyei; Alexander Kwarteng; Sabine Specht; Aurea Belda-Domene; Rolf Fimmers; Mark Taylor; Ohene Adjei; Achim Hoerauf
Journal:  Clin Infect Dis       Date:  2012-05-18       Impact factor: 9.079

9.  Progress and impact of 13 years of the global programme to eliminate lymphatic filariasis on reducing the burden of filarial disease.

Authors:  K D Ramaiah; Eric A Ottesen
Journal:  PLoS Negl Trop Dis       Date:  2014-11-20

10.  Limb volume measurements: comparison of accuracy and decisive parameters of the most used present methods.

Authors:  Adam Chromy; Ludek Zalud; Petr Dobsak; Igor Suskevic; Veronika Mrkvicova
Journal:  Springerplus       Date:  2015-11-19
View more
  9 in total

1.  Volumetric Assessment of Pediatric Vascular Malformations Using a Rapid, Hand-Held Three-Dimensional Imaging System.

Authors:  Ethan J Speir; C Matthew Hawkins; Michael J Weiler; Michael Briones; Rachel Swerdlin; Solomon Park; J Brandon Dixon
Journal:  J Digit Imaging       Date:  2019-04       Impact factor: 4.056

Review 2.  Use of technology to facilitate a prospective surveillance program for breast cancer-related lymphedema at the Massachusetts General Hospital.

Authors:  Lauren M Havens; Cheryl L Brunelle; Tessa C Gillespie; Madison Bernstein; Loryn K Bucci; Yara W Kassamani; Alphonse G Taghian
Journal:  Mhealth       Date:  2021-01-20

3.  Assessment of clinical measures of total and regional body composition from a commercial 3-dimensional optical body scanner.

Authors:  Jonathan P Bennett; Yong En Liu; Brandon K Quon; Nisa N Kelly; Michael C Wong; Samantha F Kennedy; Dominic C Chow; Andrea K Garber; Ethan J Weiss; Steven B Heymsfield; John A Shepherd
Journal:  Clin Nutr       Date:  2021-12-07       Impact factor: 7.643

4.  Subclinical Lymphedema After Treatment for Breast Cancer: Risk of Progression and Considerations for Early Intervention.

Authors:  Loryn K Bucci; Cheryl L Brunelle; Madison C Bernstein; Amy M Shui; Tessa C Gillespie; Sacha A Roberts; George E Naoum; Alphonse G Taghian
Journal:  Ann Surg Oncol       Date:  2021-06-11       Impact factor: 5.344

5.  Podoconiosis: key priorities for research and implementation.

Authors:  Kebede Deribe; Charles D Mackenzie; Melanie J Newport; Daniel Argaw; David H Molyneux; Gail Davey
Journal:  Trans R Soc Trop Med Hyg       Date:  2020-12-16       Impact factor: 2.184

6.  Alternative approaches to lymphoedema care in lymphatic filariasis.

Authors:  Suma Krishnasastry; Charles D Mackenzie
Journal:  PLoS Negl Trop Dis       Date:  2021-04-29

7.  Caring for patients in the global programme to eliminate lymphatic filariasis.

Authors:  Charles D Mackenzie; Sunny Mante
Journal:  Int Health       Date:  2020-12-22       Impact factor: 2.473

8.  Portable infrared imaging for longitudinal limb volume monitoring in patients with lymphatic filariasis.

Authors:  Celia Zhou; Channa Yahathugoda; Lalindi De Silva; Upeksha Rathnapala; Grant Owen; Mirani Weerasooriya; Ramakrishna U Rao; Gary J Weil; Philip J Budge
Journal:  PLoS Negl Trop Dis       Date:  2019-10-04

9.  An infrared 3D scanning device as a novel limb volume measurement tool in breast cancer patients.

Authors:  Bernadette N White; Iris M Lu; LeslieAnn S Kao; J Brandon Dixon; Michael J Weiler; Nathan D Frank; Jill Binkley; Preeti Subhedar; Joel Okoli; Karen Buhariwalla; Adriana Suarez-Ligon; Sheryl G A Gabram-Mendola
Journal:  World J Surg Oncol       Date:  2020-10-27       Impact factor: 2.754

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.