Literature DB >> 29140644

Evaluation of Low-Cost Hydrogen Sulfide Monitors for Use in Livestock Production.

Jessica M Beswick-Honn1, Thomas M Peters1, T Renée Anthony1.   

Abstract

Direct-reading gas monitors warn workers of the risk of potentially fatal hydrogen sulfide (H2S) exposures that may arise during manure handling. Low-cost, low-maintenance H2S monitors are available from many manufacturers, but differences in their features and performance make selection challenging for farmers. Moreover, little information is available on the practical maintenance and performance of these devices in agricultural environments. The objective of this study was to provide information to agricultural workers to aid in the selection, maintenance, and use of low-cost H2S monitors. This laboratory study evaluated the performance of several low-cost monitors over a simulated period of use of one year in a swine barn. Four models were exposed to H2S concentrations of 1 to 10 ppm over 18 weeks to examine the drift in reported concentration and changes in the alarm reaction time. Over the simulated barn year, the performance of alarm-only monitors declined faster than that of monitors displaying the H2S concentration. Of concern was the high-level (20 ppm) alarm failures after an equivalent of 139 days (Altair) and 289 days (BW Clip) in a swine barn, well within the monitor's reported shelf-life. Models displaying concentration exhibited fewer failures but were inaccurate in the displayed concentration when challenged with 20 ppm of H2S. The T40 Rattler provided consistently higher readings (+2.3 ppm), and the Pac 3500 showed consistently lower readings (-3.4 ppm) when challenged with 20 ppm. This study confirms the need for routine bump tests for these low-cost monitors to ensure that the monitor reacts to the presence of H2S, even if the manufacturer does not recommend this procedure. Most importantly, agricultural workers should inspect and bump test these monitors prior to any potentially high-risk activity, such as manure agitation, pumping, or pressure washing, to ensure that the monitor appropriately detects and warns users. Copyright© by the American Society of Agricultural Engineers.

Entities:  

Keywords:  Calibration; Direct-reading monitors; H2S; Hydrogen sulfide monitors; Manure gas; Safety, Sensors

Mesh:

Substances:

Year:  2017        PMID: 29140644      PMCID: PMC5704997          DOI: 10.13031/jash.12530

Source DB:  PubMed          Journal:  J Agric Saf Health        ISSN: 1074-7583


  12 in total

1.  Fatal harmful substances or environmental exposures in agriculture, 1992 to 1996.

Authors:  N Adekoya; J R Myers
Journal:  J Occup Environ Med       Date:  1999-08       Impact factor: 2.162

2.  Monitoring H2S to meet new exposure standards.

Authors:  Rick Wanek
Journal:  Occup Health Saf       Date:  2011-09

3.  Summation of the frequency, severity, and primary causative factors associated with injuries and fatalities involving confined spaces in agriculture.

Authors:  S M Riedel; W E Field
Journal:  J Agric Saf Health       Date:  2013-04

4.  Amperometric gas sensor response times.

Authors:  P R Warburton; M P Pagano; R Hoover; M Logman; K Crytzer; Y J Warburton
Journal:  Anal Chem       Date:  1998-03-01       Impact factor: 6.986

5.  Confined space manure storage and facilities safety assessment.

Authors:  D J Murphy; H B Manbeck
Journal:  J Agric Saf Health       Date:  2014-07

6.  Operator Exposure to Hydrogen Sulfide from Dairy Manure Storages Containing Gypsum Bedding.

Authors:  Eileen E Fabian-Wheeler; Michael L Hile; Dennis J Murphy; Davis E Hill; Robert Meinen; Robin C Brandt; Hershel A Elliott; Daniel Hofstetter
Journal:  J Agric Saf Health       Date:  2017-01-26

7.  Wintertime factors affecting contaminant distribution in a swine farrowing room.

Authors:  Kelsie A Reeve; Thomas M Peters; T Renée Anthony
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

8.  Acute toxic exposure to gases from liquid manure.

Authors:  K J Donham; L W Knapp; R Monson; K Gustafson
Journal:  J Occup Med       Date:  1982-02

9.  Summary of documented fatalities in livestock manure storage and handling facilities--1975-2004.

Authors:  Randy L Beaver; William E Field
Journal:  J Agromedicine       Date:  2007       Impact factor: 1.675

10.  Use of Recirculating Ventilation With Dust Filtration to Improve Wintertime Air Quality in a Swine Farrowing Room.

Authors:  T Renée Anthony; Ralph Altmaier; Samuel Jones; Rich Gassman; Jae Hong Park; Thomas M Peters
Journal:  J Occup Environ Hyg       Date:  2015       Impact factor: 2.155

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.