Literature DB >> 29139034

Vessel centerline reconstruction from non-isocentric and non-orthogonal paired monoplane angiographic images.

Mie Kunio1, Caroline C O'Brien2, Augusto C Lopes2, Lynn Bailey3, Pedro A Lemos4,5, Guillermo J Tearney6, Elazer R Edelman2.   

Abstract

PURPOSE: Three-dimensional reconstruction of a vessel centerline from paired planar coronary angiographic images is critical to reconstruct the complex three-dimensional structure of the coronary artery lumen and the relative positioning of implanted devices. In this study, a new vessel centerline reconstruction method that can utilize non-isocentric and non-orthogonal pairs of angiographic images was developed and tested.
METHODS: Our new method was developed in in vitro phantom models of bifurcated coronary artery with and without stent, and then tested in in vivo swine models (twelve coronary arteries). This method was also validated using data from six patients.
RESULTS: Our new method demonstrated high accuracy (root mean square error = 0.27 mm or 0.76 pixel), and high reproducibility across a broad imaging angle (20°-130°) and between different cardiac cycles in vitro and in vivo. Use of this method demonstrated that the vessel centerline in the stented segment did not deform significantly over a cardiac cycle in vivo. In addition, the total movement of the isocenter in each image could be accurately estimated in vitro and in vivo. The performance of this new method for patient data was similar to that for in vitro phantom models and in vivo animal models.
CONCLUSIONS: We developed a vessel centerline reconstruction method for non-isocentric and non-orthogonal angiographic images. It demonstrated high accuracy and good reproducibility in vitro, in vivo, and in clinical setting, suggesting that our new method is clinically applicable despite the small sample size of clinical data.

Entities:  

Keywords:  Coronary angiography; Image reconstruction; Reconstruction algorithm; Stereoscopic theory

Mesh:

Year:  2017        PMID: 29139034      PMCID: PMC5889725          DOI: 10.1007/s10554-017-1275-z

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  17 in total

1.  Quantification of the curvature and shape of the interventricular septum.

Authors:  Daniel A Moses; Leon Axel
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

2.  Three-dimensional quantitative coronary angiography.

Authors:  T Saito; M Misaki; K Shirato; T Takishima
Journal:  IEEE Trans Biomed Eng       Date:  1990-08       Impact factor: 4.538

3.  Three-dimensional coronary reconstruction from routine single-plane coronary angiograms: in vivo quantitative validation.

Authors:  Danny Dvir; Hadar Marom; Victor Guetta; Ran Kornowski
Journal:  Int J Cardiovasc Intervent       Date:  2005

4.  First direct in vivo comparison of two commercially available three-dimensional quantitative coronary angiography systems.

Authors:  Steve Ramcharitar; Joost Daeman; Mark Patterson; Robert Jan van Guens; Eric Boersma; Patrick W Serruys; Willem J van der Giessen
Journal:  Catheter Cardiovasc Interv       Date:  2008-01-01       Impact factor: 2.692

5.  Novel approach for 3-d reconstruction of coronary arteries from two uncalibrated angiographic images.

Authors:  Jian Yang; Yongtian Wang; Yue Liu; Songyuan Tang; Wufan Chen
Journal:  IEEE Trans Image Process       Date:  2009-05-02       Impact factor: 10.856

6.  External force back-projective composition and globally deformable optimization for 3-D coronary artery reconstruction.

Authors:  Jian Yang; Weijian Cong; Yang Chen; Jingfan Fan; Yue Liu; Yongtian Wang
Journal:  Phys Med Biol       Date:  2014-02-07       Impact factor: 3.609

7.  Quantitative coronary arteriography: estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation.

Authors:  B G Brown; E Bolson; M Frimer; H T Dodge
Journal:  Circulation       Date:  1977-02       Impact factor: 29.690

8.  In vivo comparison of arterial lumen dimensions assessed by co-registered three-dimensional (3D) quantitative coronary angiography, intravascular ultrasound and optical coherence tomography.

Authors:  Shengxian Tu; Liang Xu; Jurgen Ligthart; Bo Xu; Karen Witberg; Zhongwei Sun; Gerhard Koning; Johan H C Reiber; Evelyn Regar
Journal:  Int J Cardiovasc Imaging       Date:  2012-01-20       Impact factor: 2.357

9.  Fusion of 3D QCA and IVUS/OCT.

Authors:  Shengxian Tu; Niels R Holm; Gerhard Koning; Zheng Huang; Johan H C Reiber
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-25       Impact factor: 2.357

10.  Assessment of obstruction length and optimal viewing angle from biplane X-ray angiograms.

Authors:  Shengxian Tu; Gerhard Koning; Wouter Jukema; Johan H C Reiber
Journal:  Int J Cardiovasc Imaging       Date:  2009-09-18       Impact factor: 2.357

View more
  2 in total

1.  In-Vitro MPI-guided IVOCT catheter tracking in real time for motion artifact compensation.

Authors:  Florian Griese; Sarah Latus; Matthias Schlüter; Matthias Graeser; Matthias Lutz; Alexander Schlaefer; Tobias Knopp
Journal:  PLoS One       Date:  2020-03-31       Impact factor: 3.240

2.  3D localization from 2D X-ray projection.

Authors:  Dagmar Bertsche; Volker Rasche; Wolfgang Rottbauer; Ina Vernikouskaya
Journal:  Int J Comput Assist Radiol Surg       Date:  2022-07-11       Impact factor: 3.421

  2 in total