Literature DB >> 29136801

A sensitive label-free electrochemical immunosensor for detection of cytokeratin 19 fragment antigen 21-1 based on 3D graphene with gold nanopaticle modified electrode.

Yan Zeng1, Jing Bao1, Yanan Zhao1, Danqun Huo2, Mei Chen1, Mei Yang1, Huanbao Fa3, Changjun Hou4.   

Abstract

Previous studies have confirmed that cytokeratin 19 fragment antigen 21-1 (CYFRA 21-1) serves as a powerful biomarker in non-small cell lung cancer (NSCLC). Herein, we report for the first time a label-free electrochemical immunosensor for sensitive and selective detection of tumor marker CYFRA21-1. In this work, three-dimensional graphene @ gold nanoparticles (3D-G@Au) nanocomposite was modified on the glassy carbon electrode (GCE) surface to enhance the conductivity of immunosensor. The anti-CYFRA21-1 captured and fixed on the modified GCE through the cross-linking of chitosan (CS), glutaraldehyde (GA) and anti-CYFRA21-1. The differential pulse voltammetry (DPV) peak current change due to the specific interaction between anti-CYFRA21-1 and CYFRA21-1 on the modified electrode surface was utilized to detect CYFRA21-1. Under optimized conditions, the proposed electrochemical immunosensor was employed to detect CYFRA21-1 and exhibited a wide linear range of 0.25-800ngmL-1 and low detection limit of 100pgmL-1 (S/N = 3). Moreover, the recovery rates of serum samples were in the range from 95.2% to 108.7% and the developed immunosensor also shows a good correlation (less than 6.6%) with enzyme-linked immunosorbent assay (ELISA) in the detection of clinical serum samples. Therefore, it is expected that the proposed immunosensor based on a 3D-G@Au has great potential in clinical medical diagnosis of CYFRA21-1.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  3D-G@Au; Cytokeratin 19 fragment 21-1; Electrochemical immunosensor; Label-free

Mesh:

Substances:

Year:  2017        PMID: 29136801     DOI: 10.1016/j.talanta.2017.09.020

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  Copper(II) 1,4-naphthalenedicarboxylate on copper foam nanowire arrays for electrochemical immunosensing of the prostate specific antigen.

Authors:  Zi-Ang Chen; Wenbo Lu; Cancan Bao; Qiangqiang Niu; Xiaowei Cao; Hui Wang; Ru-Xin Yao
Journal:  Mikrochim Acta       Date:  2019-11-09       Impact factor: 5.833

Review 2.  A review on recent advancements in electrochemical biosensing using carbonaceous nanomaterials.

Authors:  Alireza Sanati; Mahsa Jalali; Keyvan Raeissi; Fathallah Karimzadeh; Mahshid Kharaziha; Sahar Sadat Mahshid; Sara Mahshid
Journal:  Mikrochim Acta       Date:  2019-11-13       Impact factor: 5.833

Review 3.  Carbon Nanomaterials: Synthesis, Functionalization and Sensing Applications.

Authors:  Giorgio Speranza
Journal:  Nanomaterials (Basel)       Date:  2021-04-09       Impact factor: 5.076

4.  An ultrasensitive ratiometric immunosensor based on the ratios of conjugated distyrylbenzene derivative nanosheets with AIECL properties and electrochemical signal for CYFRA21-1 detection.

Authors:  Xiaoyi Lv; Mengmeng Bi; Xiaoyun Xu; Yanping Li; Chao Geng; Bo Cui; Yishan Fang
Journal:  Anal Bioanal Chem       Date:  2021-11-05       Impact factor: 4.142

5.  Electrochemiluminescent immunoassay for the lung cancer biomarker CYFRA21-1 using MoOx quantum dots.

Authors:  Xiangying Meng; Xiao Chen; Weihua Wu; Wei Zheng; Haohua Deng; Luyao Xu; Wei Chen; Zhulai Li; Huaping Peng
Journal:  Mikrochim Acta       Date:  2019-11-29       Impact factor: 5.833

6.  Graphene based electrochemical immunosensor for the ultra-sensitive label free detection of Alzheimer's beta amyloid peptides Aβ(1-42).

Authors:  Hina Y Abbasi; Zari Tehrani; Anitha Devadoss; Muhammad Munem Ali; Soraya Moradi-Bachiller; Diego Albani; Owen J Guy
Journal:  Nanoscale Adv       Date:  2021-02-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.