Literature DB >> 29135878

Single-Sided Deafness: Impact of Cochlear Implantation on Speech Perception in Complex Noise and on Auditory Localization Accuracy.

Julia Döge1, Uwe Baumann, Tobias Weissgerber, Tobias Rader.   

Abstract

OBJECTIVE: To assess auditory localization accuracy and speech reception threshold (SRT) in complex noise conditions in adult patients with acquired single-sided deafness, after intervention with a cochlear implant (CI) in the deaf ear. STUDY
DESIGN: Nonrandomized, open, prospective patient series.
SETTING: Tertiary referral university hospital. PATIENTS: Eleven patients with late-onset single-sided deafness (SSD) and normal hearing in the unaffected ear, who received a CI. All patients were experienced CI users. INTERVENTION: Unilateral cochlear implantation. MAIN OUTCOME MEASURES: Speech perception was tested in a complex multitalker equivalent noise field consisting of multiple sound sources. Speech reception thresholds in noise were determined in aided (with CI) and unaided conditions. Localization accuracy was assessed in complete darkness. Acoustic stimuli were radiated by multiple loudspeakers distributed in the frontal horizontal plane between -60 and +60 degrees.
RESULTS: In the aided condition, results show slightly improved speech reception scores compared with the unaided condition in most of the patients. For 8 of the 11 subjects, SRT was improved between 0.37 and 1.70 dB. Three of the 11 subjects showed deteriorations between 1.22 and 3.24 dB SRT. Median localization error decreased significantly by 12.9 degrees compared with the unaided condition.
CONCLUSION: CI in single-sided deafness is an effective treatment to improve the auditory localization accuracy. Speech reception in complex noise conditions is improved to a lesser extent in 73% of the participating CI SSD patients. However, the absence of true binaural interaction effects (summation, squelch) impedes further improvements. The development of speech processing strategies that respect binaural interaction seems to be mandatory to advance speech perception in demanding listening situations in SSD patients.

Entities:  

Mesh:

Year:  2017        PMID: 29135878     DOI: 10.1097/MAO.0000000000001520

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  9 in total

1.  [A sound reproduction system using wave field synthesis to simulate everyday listening conditions].

Authors:  T Weißgerber
Journal:  HNO       Date:  2019-04       Impact factor: 1.284

2.  The impact of etiology and duration of deafness on speech perception outcomes in SSD patients.

Authors:  Anja Kurz; Marius Grubenbecher; Kristen Rak; Rudolf Hagen; Heike Kühn
Journal:  Eur Arch Otorhinolaryngol       Date:  2019-09-18       Impact factor: 2.503

3.  Hearing rehabilitation for unilateral deafness using a cochlear implant: the influence of the subjective duration of deafness on speech intelligibility.

Authors:  Tobias Rader; Oliver Julian Waleka; Sebastian Strieth; Klaus Wolfgang Georg Eichhorn; Andrea Bohnert; Dimitrios Koutsimpelas; Christoph Matthias; Benjamin Philipp Ernst
Journal:  Eur Arch Otorhinolaryngol       Date:  2022-07-06       Impact factor: 2.503

4.  Restoration of spatial hearing in adult cochlear implant users with single-sided deafness.

Authors:  Ruth Y Litovsky; Keng Moua; Shelly Godar; Alan Kan; Sara M Misurelli; Daniel J Lee
Journal:  Hear Res       Date:  2018-04-14       Impact factor: 3.208

5.  Development of a Smartphone-Based Digits-in-Noise Test in Korean: a Hearing Screening Tool for Speech Perception in Noise.

Authors:  Ji Hye Han; Dong Woon Yi; Jihyun Lee; Won Du Chang; Hyo Jeong Lee
Journal:  J Korean Med Sci       Date:  2020-06-01       Impact factor: 2.153

6.  Core Rehabilitation Outcome Set for Single Sided Deafness (CROSSSD) study: protocol for an international consensus on outcome measures for single sided deafness interventions using a modified Delphi survey.

Authors:  Roulla Katiri; Deborah A Hall; Nora Buggy; Nicholas Hogan; Adele Horobin; Paul van de Heyning; Jill B Firszt; Iain A Bruce; Pádraig T Kitterick
Journal:  Trials       Date:  2020-03-04       Impact factor: 2.279

7.  Sensitivity to interaural time differences and localization accuracy in cochlear implant users with combined electric-acoustic stimulation.

Authors:  Monika Körtje; Uwe Baumann; Timo Stöver; Tobias Weissgerber
Journal:  PLoS One       Date:  2020-10-19       Impact factor: 3.240

Review 8.  Systematic review of outcome domains and instruments used in designs of clinical trials for interventions that seek to restore bilateral and binaural hearing in adults with unilateral severe to profound sensorineural hearing loss ('single-sided deafness').

Authors:  Roulla Katiri; Deborah A Hall; Catherine F Killan; Sandra Smith; Pattarawadee Prayuenyong; Pádraig T Kitterick
Journal:  Trials       Date:  2021-03-20       Impact factor: 2.279

9.  Rapid Assessment of Non-Verbal Auditory Perception in Normal-Hearing Participants and Cochlear Implant Users.

Authors:  Agathe Pralus; Ruben Hermann; Fanny Cholvy; Pierre-Emmanuel Aguera; Annie Moulin; Pascal Barone; Nicolas Grimault; Eric Truy; Barbara Tillmann; Anne Caclin
Journal:  J Clin Med       Date:  2021-05-13       Impact factor: 4.241

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.